50 amp 3/4 Pole DC Coil Contactor, 12V/24V/48V/220V Coil

$156.92
50A 3 or 4 pole AC contactor is an electrical switching device with DC control to control electric motors, lighting and other electrical loads at 12V, 24V, 36V, 48V, 110V, 220V coil rated voltage. Rated power up to 37 kW, contact form 3 NO or 2NO+2NC for your choices.
SKU: ATO-DCCON-50A
*
*
Free Shipping
Delivery date: 6-12 days

DC contactor works to connect and break of the circuit load, which can fully meet the special demand of electric locomotive, diesel locomotive and electric motor car group. It is widely used in the control system of DC electric control, storage battery circuit and capacitance circuit.

Specification

ModelATO-CJX2-50ZATO-CJX2-50008Z
Rated Current50A AC
Coil Rated Voltage (Optional)12V DC, 24V DC, 36V DC, 48V DC, 110V DC, 220V DC
Contact Form (Optional)3 Pole (3NO)+1NO+1NC4 Pole (2NO+2NC)
Frequency50Hz/ 60Hz AC
Rated Power (AC-3)200-240V15kW (20HP)
380-440V22kW (30HP)
500-550V37kW (50HP)
600-690V37kW (50HP)
Conventional Thermal Current80A
Operating Temperature-40℃~85℃
Operating Humidity5~95% RH
Dimensions77 x 129 x 172mm84 x 129 x 184mm
Weight2.5kg

Circuits Diagram

50 amp DC Contactor Circuit Diagram

Details

50 Amp DC Contactor Details

Tips: The composition of DC contactor

The DC contactor is composed of electromagnetic mechanism, contact system and arc extinguishing device. For example, the electromagnetic mechanism is composed of an iron core, a pull-in coil, and an armature, and mostly adopts a clap-type structure that rotates around the corners. Since the current passing through the pull-in coil is DC, under normal circumstances, the energization in the coil will not generate eddy current on the iron core, so that the iron core does not generate heat, so it has no iron loss, so the iron core can be made of integral cast iron or cast steel. The number of turns of the coil winding of the DC low-voltage contactor is larger than that of the AC contactor coil, so the resistance value of the DC contactor coil is relatively large.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Seems Well Made for the Cost
4
Tomas
Avatar
8/23/2022 3:39 AM
I combined this with a WiFi Smart Relay to make a heavy duty smart control for my water heater. I spend a lot of time working on the road for weeks at a time and now I can turn the water heater back on a couple of hours from home to take a shower when I get home. So far it is operating quite well and I haven't had any issues.
Was this review helpful? Yes No (1/0)
Questions about contactor
5
Alston
Avatar
8/1/2023 2:30 AM
We have a contactor from you guys which states is a DC contactor however it also states its an AC contactor with no further details.
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, we do not provide DC current rating of the contactor.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

DC contactor works to connect and break of the circuit load, which can fully meet the special demand of electric locomotive, diesel locomotive and electric motor car group. It is widely used in the control system of DC electric control, storage battery circuit and capacitance circuit.

Specification

ModelATO-CJX2-50ZATO-CJX2-50008Z
Rated Current50A AC
Coil Rated Voltage (Optional)12V DC, 24V DC, 36V DC, 48V DC, 110V DC, 220V DC
Contact Form (Optional)3 Pole (3NO)+1NO+1NC4 Pole (2NO+2NC)
Frequency50Hz/ 60Hz AC
Rated Power (AC-3)200-240V15kW (20HP)
380-440V22kW (30HP)
500-550V37kW (50HP)
600-690V37kW (50HP)
Conventional Thermal Current80A
Operating Temperature-40℃~85℃
Operating Humidity5~95% RH
Dimensions77 x 129 x 172mm84 x 129 x 184mm
Weight2.5kg

Circuits Diagram

50 amp DC Contactor Circuit Diagram

Details

50 Amp DC Contactor Details

Tips: The composition of DC contactor

The DC contactor is composed of electromagnetic mechanism, contact system and arc extinguishing device. For example, the electromagnetic mechanism is composed of an iron core, a pull-in coil, and an armature, and mostly adopts a clap-type structure that rotates around the corners. Since the current passing through the pull-in coil is DC, under normal circumstances, the energization in the coil will not generate eddy current on the iron core, so that the iron core does not generate heat, so it has no iron loss, so the iron core can be made of integral cast iron or cast steel. The number of turns of the coil winding of the DC low-voltage contactor is larger than that of the AC contactor coil, so the resistance value of the DC contactor coil is relatively large.

Product reviews
Seems Well Made for the Cost
4
Tomas
Avatar
8/23/2022 3:39 AM
I combined this with a WiFi Smart Relay to make a heavy duty smart control for my water heater. I spend a lot of time working on the road for weeks at a time and now I can turn the water heater back on a couple of hours from home to take a shower when I get home. So far it is operating quite well and I haven't had any issues.
Was this review helpful? Yes No (1/0)
Questions about contactor
5
Alston
Avatar
8/1/2023 2:30 AM
We have a contactor from you guys which states is a DC contactor however it also states its an AC contactor with no further details.
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, we do not provide DC current rating of the contactor.
Only registered users can write reviews
Customers who bought this item also bought

200A DC Contactor, 12V/24V/48V

ATO-DCCON-C200
$121.65
This 200 amps contactor is available in coil voltage 12V, 24V, 48V, continuous operating duty, normally open (NO) or normally closed (NC) contact form, high quality DC contactor with high-performance quality, low cost and manufacturer direct sale.

100A DC Contactor, 12V/24V/48V

ATO-DCCON-C100
$103.63
High performance 100A DC contactor with normally open or normally closed main contact type, and available with two optional auxiliary contacts. Coil rated voltage with 12V/24V/48V for selection, main contact voltage drop at 100A, not above 100mV.