150A High Voltage DC Contactor, 12V/24V coil

$154.92
High voltage contactor, 150A rated load current of contact circuit, operating voltage up to 900V, normally open type (SPST-NO), is specially design to meet the requirements of high voltage DC switching applications.
SKU: ATO-DCCON-HV150
*
Free Shipping
Delivery date: 6-12 days

Features

  • DC 12-900V rated load voltage of contact circuit.
  • Normally open type (SPST-NO) of contact form, 12 volt, 24 volt coil for selecting.
  • Main contact voltage drop at 150A, not above 100mV.
  • The connection of contact and coil need to be nonpolarity.
  • Efficient coil, retentive power is only 2-2.3W, counter electromotive force is 0V.
  • The joint way of the coil is very convenient.
  • The coil has no counter force of electromagnetism.
  • Compare to the similar products, this product is smallest and lightest.

Specifications

BasicsModelATO-ADH150
Dimension80 x 65 x 67 mm
Weight440 g
Main Contact ParametersContact Form1 NO
Leading-OutM6 Internal thread
Rated Load Current150 A
Rated Load Voltage12 – 900V DC
Maximum Switching Current1500A 320V DC (≥1 times)
Maximum Switching Power480 kW
Coil ParametersStandard Type Voltage12/24V DC
Work Voltage8~36V
Max Voltage36 V
Coil Resistance3.1Ω
Average Holding Current0.14 A
Steady State Power1.7~2 W
Actuation Time≤30 ms
Release Time≤10 ms
Bounce Time≤5 ms
Mechanical SpecificationStability196 m/s2 (20G)
Strength490 m/s2 (50G)
Vibration80 ~2000Hz 98m/s2 (20G)
IP GradeIP67
EnvironmentOperating Temperature-40℃~85℃
Operating Humidity5~95% RH

Installation Diagram (Unit: mm)
high voltage 150a dc contactor dimension 1
high voltage 150a dc contactor dimension 2High Voltage DC Contactor Coil Schematic
high voltage dc contactor coil schematic

Details

150A High Voltage DC Contactor Details

Tips: Magnetic blowing device working principle of a DC concactor

When the contactor’s movable and static contacts disconnect, arc will generate between the contacts, the arc still maintains the load current within a short period of time. At this moment, two magnetic fields will generate before the arc extinguishes. One magnetic field is formed by the current around the arc, of which the direction can be determined by the Ampere's rule. Moreover, there’s still another magnetic field around the arc, which is produced between two magnetic splints by the current when it flows the blowout coils. This magnetic field passes the iron core and goes through one magnetic splint, it enters another magnetic splint through the gap and forms a closed magnetic circuit.
Obviously, above the arc, the magnetic field between two magnetic splints has an opposite direction with that of the magnetic field around the arc, the magnetic field intensity is also weaker. Below the arc, the two the magnetic fields have same direction and the field intensity strengthens. Therefore, the arc will be pulled from the strong side of the magnetic field to the weak side, it moves upwards. In this process, the arc will be quickly elongated and form a relative motion with the air, thus reducing the arc temperature. Meanwhile, when the arc is blown to the upper part of arc chute, the heat of the arc will be transferred to the arc chute, thus further reducing the arc temperature, promoting the rapid extinction of the arc.

Product reviews
Do you provide 150A high voltage DC contactor with N/C auxiliary?
5
Ray Brett
Avatar
7/16/2019 6:58 PM
Do you provide high voltage DC contactor 120v of model: ATO-DCCON-HV150 with N/C auxiliary? If yes, what is the price includes Shipping To Netherlands?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately don't provide NC auxiliary for 120VDC, but can provide for up to 80VDC operating voltage (low voltage DC conatctor).
Does the option ATO-ADH150 attend max coil current of 2A?
5
Abner
Avatar
5/27/2022 1:29 AM
We are looking to find alternative parts for a replacement of our 150amp contactor. Does the option ATO-ADH150 attend max coil current of 2 amp?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, this contactor ATO-ADH150 has a maximum coil current of 2A at the moment of startup.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Features

  • DC 12-900V rated load voltage of contact circuit.
  • Normally open type (SPST-NO) of contact form, 12 volt, 24 volt coil for selecting.
  • Main contact voltage drop at 150A, not above 100mV.
  • The connection of contact and coil need to be nonpolarity.
  • Efficient coil, retentive power is only 2-2.3W, counter electromotive force is 0V.
  • The joint way of the coil is very convenient.
  • The coil has no counter force of electromagnetism.
  • Compare to the similar products, this product is smallest and lightest.

Specifications

BasicsModelATO-ADH150
Dimension80 x 65 x 67 mm
Weight440 g
Main Contact ParametersContact Form1 NO
Leading-OutM6 Internal thread
Rated Load Current150 A
Rated Load Voltage12 – 900V DC
Maximum Switching Current1500A 320V DC (≥1 times)
Maximum Switching Power480 kW
Coil ParametersStandard Type Voltage12/24V DC
Work Voltage8~36V
Max Voltage36 V
Coil Resistance3.1Ω
Average Holding Current0.14 A
Steady State Power1.7~2 W
Actuation Time≤30 ms
Release Time≤10 ms
Bounce Time≤5 ms
Mechanical SpecificationStability196 m/s2 (20G)
Strength490 m/s2 (50G)
Vibration80 ~2000Hz 98m/s2 (20G)
IP GradeIP67
EnvironmentOperating Temperature-40℃~85℃
Operating Humidity5~95% RH

Installation Diagram (Unit: mm)
high voltage 150a dc contactor dimension 1
high voltage 150a dc contactor dimension 2High Voltage DC Contactor Coil Schematic
high voltage dc contactor coil schematic

Details

150A High Voltage DC Contactor Details

Tips: Magnetic blowing device working principle of a DC concactor

When the contactor’s movable and static contacts disconnect, arc will generate between the contacts, the arc still maintains the load current within a short period of time. At this moment, two magnetic fields will generate before the arc extinguishes. One magnetic field is formed by the current around the arc, of which the direction can be determined by the Ampere's rule. Moreover, there’s still another magnetic field around the arc, which is produced between two magnetic splints by the current when it flows the blowout coils. This magnetic field passes the iron core and goes through one magnetic splint, it enters another magnetic splint through the gap and forms a closed magnetic circuit.
Obviously, above the arc, the magnetic field between two magnetic splints has an opposite direction with that of the magnetic field around the arc, the magnetic field intensity is also weaker. Below the arc, the two the magnetic fields have same direction and the field intensity strengthens. Therefore, the arc will be pulled from the strong side of the magnetic field to the weak side, it moves upwards. In this process, the arc will be quickly elongated and form a relative motion with the air, thus reducing the arc temperature. Meanwhile, when the arc is blown to the upper part of arc chute, the heat of the arc will be transferred to the arc chute, thus further reducing the arc temperature, promoting the rapid extinction of the arc.

Product reviews
Do you provide 150A high voltage DC contactor with N/C auxiliary?
5
Ray Brett
Avatar
7/16/2019 6:58 PM
Do you provide high voltage DC contactor 120v of model: ATO-DCCON-HV150 with N/C auxiliary? If yes, what is the price includes Shipping To Netherlands?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately don't provide NC auxiliary for 120VDC, but can provide for up to 80VDC operating voltage (low voltage DC conatctor).
Does the option ATO-ADH150 attend max coil current of 2A?
5
Abner
Avatar
5/27/2022 1:29 AM
We are looking to find alternative parts for a replacement of our 150amp contactor. Does the option ATO-ADH150 attend max coil current of 2 amp?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, this contactor ATO-ADH150 has a maximum coil current of 2A at the moment of startup.
Only registered users can write reviews
Customers who bought this item also bought

300A High Voltage DC Contactor, 12V/24V coil

ATO-DCCON-HV300
$186.15
The ATO-ADH300 contactor has been designed for DC loads, particularly for DC high voltage field, operating voltage up to 900V. 300A rated load current of contact circuit, normal open (SPST-NO) main contacts with silver alloy tips, which are weld resistant, hard wearing and have excellent conductivity.

400A High Voltage DC Contactor, 12V/24V coil

ATO-DCCON-HV400
$220.49
Favorable price high voltage DC contactor for sale, with 400 amps rated load current of contact circuit, 1NO or 1NC contact form, available with 6V/12V/24V/36V/48V/60V/72V/84V/120V/150V/220V DC, 220V AC coils. This magnetic HVDC contactor is an electrical device designed to control and switch high voltage direct current circuits.