20 kVA Isolation Transformer, 3 phase, 380V to 190V

$3,853.97
High performance 20kVA isolation transformer is designed to step down/up the 3 phase voltage 380V to 190V. Primary and secondary windings are separated by aluminium/copper shield, and widely used in various power supply sites with frequency 50Hz/60Hz.
SKU: ATO-T-SG20KVA
*
*
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 10-16 days

High quality and safety isolating transformers, 3 phase, 20kVA power rating, 380V AC input voltage to 190V AC output voltage, is a is a non-ventilated isolation transformer rated for hazardous locations as well as harsh industrial environments.

20 kVA Isolation Transformer Specifications

BasicsModelATO-SG20KVA
Phase3 phase
Capacity20 kVA
Weight of Aluminium Wire TransformerOpen type: 113kg
Protected type: 140kg
Weight of Copper Wire TransformerOpen type: 123kg
Protected type: 148kg
Technical ParametersPrimary Voltage380V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Secondary Voltage190V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Voltage ConvertThree phase to three phase
Frequency50Hz / 60 Hz
Winding MaterialAluminium/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength3000V AC/1 min
Noise<35-65dB (1 meter)
Insulation GradeH level
Wiring ModeDyn11
Cooling ModeDry type air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 4 hours
Enclosure Protection GradeIP 24
CertificateCE, ISO
Warranty12 months
Working EnvironmentTemperature-15℃~+40℃
Humidity≤90%RH, without condensation
Altitude<1000m, non corrosive gas and conductive dust

Note:

Transformer can only convert voltage and CANNOT convert frequency.
Transformer CANNOT convert single phase voltage to 3 phase voltage.
Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients' requirements.

3 Phase Isolation Transformer Schematic Diagram

ATO isolation transformers schematic diagram

3 Phase Isolation Transformer Details

3-phase isolation transformer details

20 kVA Isolation Transformer Installation Dimension

3 phase isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=440*310*430mmOpen type: a*b*c=440*310*420mm
Mouting size: d*e=300*165mmMouting size: d*e=300*165mm
Protected type: A*B*C=420*610*610mmProtected type: A*B*C=420*610*610mm

Tips: 3 phase isolation transformer loss

When the 3 phase isolation transformer output power is equal to the input power, the efficiency reaches 100%, the transformer will not generate any loss. But in fact this kind of transformer does not exist. Transformer always generates loss during electricity transmission, this kind of loss mainly includes copper loss and iron loss. Copper loss refers to the loss caused by step up & step down transformer coil resistance. When the current goes through the coil resistance and gets heated, part of the electrical energy is consumed and becomes heat loss. Since the coil is generally twined with insulated copper wire, it is called copper loss.

Iron loss of the transformer includes two aspects. The first one is the hysteresis loss, when the alternating current goes through the transformer, the direction and magnitude of the magnetic lines through the transformer silicon steel sheet changes, causing friction among the molecules within the silicon steel sheet and heat is released, this process consumes part of the electricity. The other is eddy current loss during the working of isolation transformer. When the magnetic line of force goes through iron core, current will be induced on the plane vertical to the magnetic line of force, since the current forms a closed loop and becomes ring current which shapes an eddy, it is called eddy current. The existence of eddy current makes the core heat and consumes energy, this loss is called eddy current loss.

How to Test Step Up & Step Down Isolation Transformer?

Need more detail of ATO isolation transformer? Here is a good explanation about it in this video. To test the accuracy of the transformer voltage, we take a 3000 VA single phase 220V iuput to 110V output isolation transformer as an example.

Product reviews
Could this 20 kVA isolation transformer eliminate the disturbance of harmonics?
5
Tom Rosser
Avatar
5/28/2018 12:39 AM
I have added reactors to the input and output terminals of my equipment, and have not eliminated the disturbance of harmonics. Could this 20 kVA isolation transformer help me solve the problem?
Was this review helpful? Yes No (0/0)
ATO Responded
Dear friend, ATO isolation transformers are not only step up & step down transformers, but also belongs to the safe power source, which can prevent the transmission of some harmonics and protect the device.
Completely soundless and odorless
5
Elzabeth
Avatar
7/13/2018 11:40 PM
The isolation transformer performs just as I hoped it would. I use it in the US to run 220V European appliances on US 120V current. Completely soundless and odorless.
Was this review helpful? Yes No (0/0)
Great step up and step down isolation transformer
5
Pierce Primm
Avatar
2/14/2019 7:01 PM
Great step up and step down isolation transformer. I am quite pleased with this product. Although it is a little heavy but then fit for purpose.
Was this review helpful? Yes No (0/0)
Exactly what I needed.
5
Roger
Avatar
10/10/2019 7:28 PM
We recently relocated to the USA from Europe. I have a machine with an EU power and so the voltage is not compatible. However after doing research, I saw that people had got it working using this product and so I tried it out. I found this isolation transformer to be a good value for my device.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

High quality and safety isolating transformers, 3 phase, 20kVA power rating, 380V AC input voltage to 190V AC output voltage, is a is a non-ventilated isolation transformer rated for hazardous locations as well as harsh industrial environments.

20 kVA Isolation Transformer Specifications

BasicsModelATO-SG20KVA
Phase3 phase
Capacity20 kVA
Weight of Aluminium Wire TransformerOpen type: 113kg
Protected type: 140kg
Weight of Copper Wire TransformerOpen type: 123kg
Protected type: 148kg
Technical ParametersPrimary Voltage380V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Secondary Voltage190V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Voltage ConvertThree phase to three phase
Frequency50Hz / 60 Hz
Winding MaterialAluminium/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength3000V AC/1 min
Noise<35-65dB (1 meter)
Insulation GradeH level
Wiring ModeDyn11
Cooling ModeDry type air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 4 hours
Enclosure Protection GradeIP 24
CertificateCE, ISO
Warranty12 months
Working EnvironmentTemperature-15℃~+40℃
Humidity≤90%RH, without condensation
Altitude<1000m, non corrosive gas and conductive dust

Note:

Transformer can only convert voltage and CANNOT convert frequency.
Transformer CANNOT convert single phase voltage to 3 phase voltage.
Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients' requirements.

3 Phase Isolation Transformer Schematic Diagram

ATO isolation transformers schematic diagram

3 Phase Isolation Transformer Details

3-phase isolation transformer details

20 kVA Isolation Transformer Installation Dimension

3 phase isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=440*310*430mmOpen type: a*b*c=440*310*420mm
Mouting size: d*e=300*165mmMouting size: d*e=300*165mm
Protected type: A*B*C=420*610*610mmProtected type: A*B*C=420*610*610mm

Tips: 3 phase isolation transformer loss

When the 3 phase isolation transformer output power is equal to the input power, the efficiency reaches 100%, the transformer will not generate any loss. But in fact this kind of transformer does not exist. Transformer always generates loss during electricity transmission, this kind of loss mainly includes copper loss and iron loss. Copper loss refers to the loss caused by step up & step down transformer coil resistance. When the current goes through the coil resistance and gets heated, part of the electrical energy is consumed and becomes heat loss. Since the coil is generally twined with insulated copper wire, it is called copper loss.

Iron loss of the transformer includes two aspects. The first one is the hysteresis loss, when the alternating current goes through the transformer, the direction and magnitude of the magnetic lines through the transformer silicon steel sheet changes, causing friction among the molecules within the silicon steel sheet and heat is released, this process consumes part of the electricity. The other is eddy current loss during the working of isolation transformer. When the magnetic line of force goes through iron core, current will be induced on the plane vertical to the magnetic line of force, since the current forms a closed loop and becomes ring current which shapes an eddy, it is called eddy current. The existence of eddy current makes the core heat and consumes energy, this loss is called eddy current loss.

Product reviews
Could this 20 kVA isolation transformer eliminate the disturbance of harmonics?
5
Tom Rosser
Avatar
5/28/2018 12:39 AM
I have added reactors to the input and output terminals of my equipment, and have not eliminated the disturbance of harmonics. Could this 20 kVA isolation transformer help me solve the problem?
Was this review helpful? Yes No (0/0)
ATO Responded
Dear friend, ATO isolation transformers are not only step up & step down transformers, but also belongs to the safe power source, which can prevent the transmission of some harmonics and protect the device.
Completely soundless and odorless
5
Elzabeth
Avatar
7/13/2018 11:40 PM
The isolation transformer performs just as I hoped it would. I use it in the US to run 220V European appliances on US 120V current. Completely soundless and odorless.
Was this review helpful? Yes No (0/0)
Great step up and step down isolation transformer
5
Pierce Primm
Avatar
2/14/2019 7:01 PM
Great step up and step down isolation transformer. I am quite pleased with this product. Although it is a little heavy but then fit for purpose.
Was this review helpful? Yes No (0/0)
Exactly what I needed.
5
Roger
Avatar
10/10/2019 7:28 PM
We recently relocated to the USA from Europe. I have a machine with an EU power and so the voltage is not compatible. However after doing research, I saw that people had got it working using this product and so I tried it out. I found this isolation transformer to be a good value for my device.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

5 kVA Isolation Transformer, 3 phase, 480V to 400V

ATO-T-SG5KVA
$1,776.92
3 phase 5 kVA isolation transformer is designed to step down/ up the voltage 480V to 400V, and widely used in various power supply sites with frequency 50Hz or 60Hz.