1/4 hp Non-Enclosure VFD, 1ph Input, 3ph Output

$129.89
Customized no shell single phase VFD for sale, 1/4 hp (200 W) capacity variable speed drive, convert single phase 208~240v to 3ph, with operation keyboard, high torque output, high accurate control, suitable for various motor speed controls.
SKU: GK3300-2S0002
Free Shipping
Delivery date: 6-12 days

1/4 hp single phase VFD without enclosure, 0.2 kW, 220V single phase to 3 phase 220 volt output variable frequency drive, sale by manufacturer directly.

Specification:

BasicsModelGK3300-2S0002
Capacity1/4 hp (0.2 kW)
Shipping weight665 g
Dimension (L*W*H)151*104*73 mm
I/O FeatureRated current1.6 A
Input voltage1 phase 220~240V AC
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: The application usually determines the control mode of the VFD
Volts per Hertz (V/F)
V/F controls the ratio between voltage and frequency to change the motor flux, thereby providing the motor with operating torque. The V/F drive works well for most applications such as fans and water pumps.
Sensorless vector
Sensorless vector VFDs are known for their precise speed control over a wide speed range without encoder feedback, because they work well in open loop. The closed loop VFD uses encoder feedback to perform precise speed control by monitoring the actual motor speed and slip information. Sensorless vector and closed-loop VFD have excellent speed regulation, providing accurate speed control for paper mills, printing presses and other conversion applications.

This video includes three parts: 1. What is customized equipment? 2. Difference between non-enclosure and standard VFDs. 3. Pratical operation of ATO non-enclosure VFD. All above explains the features, functions and working of non-enclosure VFD.

In this video, ATO will show you the vfd basic troubleshooting guide.

This video will show you how to measure electrical circuit using digital multimeter.

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

Product reviews
Great customer service
5
Knives
Avatar
2/23/2021 11:15 PM
I asked a question here about non enclosure VFD and they responded to me directly and gave me their email contact information. Thank you so much for wonderful customer service!!!
Was this review helpful? Yes No (1/0)
The difference between variable frequency drive operation
5
Fred
Avatar
8/22/2021 11:52 PM
What is the difference between 5hp, and 7hp 1-phase to 3-phase drive if I use to run 9Amps at 230VAC motor?
Was this review helpful? Yes No (0/0)
ATO Responded
The 2 driving models have the same performance durability, and for a VFD rated motor which draws no more than 9Amps at 230VAC, we recommend using the 5hp model (GK3000-2S0037).
How to start and run 1/4hp non enclosure VFD?
5
Mrhaynes
Avatar
9/2/2021 1:09 AM
Is there a way to use the one we have in the field?
The amperage is close enough if we raise or drop the voltage or bypass anything in the system to get it to work in the interim? It is installed and anything we can do to get it up and running right now?
Was this review helpful? Yes No (1/0)
ATO Responded
You can set the 1/4hp non enclosure VFD with the following parameters, and test again.
Has this VFD been approved?
5
Dana
Avatar
12/3/2021 1:58 AM
Is this VFD CSA approved? And what is the max amperage input, recommended breaker (2hp VFD 120V single phase input-220V 3 phase output).
Was this review helpful? Yes No (0/0)
ATO Responded
1. CE approved only.
2. Input Current: 14A, Breaker Rating: Not less than 20A.
delivery in india
5
Rajat
Avatar
5/3/2024 3:39 AM
Can it be delivered in india ?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it can.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

1/4 hp single phase VFD without enclosure, 0.2 kW, 220V single phase to 3 phase 220 volt output variable frequency drive, sale by manufacturer directly.

Specification:

BasicsModelGK3300-2S0002
Capacity1/4 hp (0.2 kW)
Shipping weight665 g
Dimension (L*W*H)151*104*73 mm
I/O FeatureRated current1.6 A
Input voltage1 phase 220~240V AC
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: The application usually determines the control mode of the VFD
Volts per Hertz (V/F)
V/F controls the ratio between voltage and frequency to change the motor flux, thereby providing the motor with operating torque. The V/F drive works well for most applications such as fans and water pumps.
Sensorless vector
Sensorless vector VFDs are known for their precise speed control over a wide speed range without encoder feedback, because they work well in open loop. The closed loop VFD uses encoder feedback to perform precise speed control by monitoring the actual motor speed and slip information. Sensorless vector and closed-loop VFD have excellent speed regulation, providing accurate speed control for paper mills, printing presses and other conversion applications.

Product reviews
Great customer service
5
Knives
Avatar
2/23/2021 11:15 PM
I asked a question here about non enclosure VFD and they responded to me directly and gave me their email contact information. Thank you so much for wonderful customer service!!!
Was this review helpful? Yes No (1/0)
The difference between variable frequency drive operation
5
Fred
Avatar
8/22/2021 11:52 PM
What is the difference between 5hp, and 7hp 1-phase to 3-phase drive if I use to run 9Amps at 230VAC motor?
Was this review helpful? Yes No (0/0)
ATO Responded
The 2 driving models have the same performance durability, and for a VFD rated motor which draws no more than 9Amps at 230VAC, we recommend using the 5hp model (GK3000-2S0037).
How to start and run 1/4hp non enclosure VFD?
5
Mrhaynes
Avatar
9/2/2021 1:09 AM
Is there a way to use the one we have in the field?
The amperage is close enough if we raise or drop the voltage or bypass anything in the system to get it to work in the interim? It is installed and anything we can do to get it up and running right now?
Was this review helpful? Yes No (1/0)
ATO Responded
You can set the 1/4hp non enclosure VFD with the following parameters, and test again.
Has this VFD been approved?
5
Dana
Avatar
12/3/2021 1:58 AM
Is this VFD CSA approved? And what is the max amperage input, recommended breaker (2hp VFD 120V single phase input-220V 3 phase output).
Was this review helpful? Yes No (0/0)
ATO Responded
1. CE approved only.
2. Input Current: 14A, Breaker Rating: Not less than 20A.
delivery in india
5
Rajat
Avatar
5/3/2024 3:39 AM
Can it be delivered in india ?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it can.
Only registered users can write reviews
Customers who bought this item also bought

Custom Order

ATO-CUSTOM
Pay for custom orders, or extra amount of existing orders.
Indicate the item specification you pay for, and specify PI / PO number if you have.