1/2 hp VFD, Single Phase to Three Phase VFD

$149.10
1/2 hp VFD, convert single phase to three phase for AC motor speed controls, 208V - 240V 3 amps, IP20, RS485 enabled, manufacturer direct sale.
SKU: GK3000-2S0004
Availability: In stock
Free Shipping
Delivery date: 2-12 days

1/2 hp VFD, 0.4 kW, 208V - 240V single phase to three phase variable frequency drive, sale by manufacturer directly.

Specification:

BasicsModelGK3000-2S0004
Capacity1/2 hp (0.4 kW)
Shipping weight2 kg
Dimension142*85*110 mm
I/O FeatureRated current3 A
Input voltage1 phase 220~240V AC
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F, Sensorless vector control (SVC), Speed sensor vector control (FVC)
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

400W VFD Single Phase to Three Phase VFD Details

Tips: Variable frequency drive hardware replacement precautions

  1. Replace the IGBT. Measure whether the resistance value of each road is balanced.
  2. Replace the drive board. Need to carefully check whether the plug and socket number is consistent.
  3. Replace the main control board. After replacing the main control board, set the application parameters, motor parameters and protection parameters of VFD.
  4. Replace the PG card. Check whether the terminals are normal. If the motor has a vibration or cannot rotate after replacing the card, need to exchange the A and B phase.
  5. Replace the communication board. Simply check the DIP switch set by VFD hardware station number, and then check that the communication light is normal.
  6. The communication board of some VFD series is an independent CPU. After the replacement, need to upload configuration program.

VFD Analog Input 0-10V Frequency Control (VI Port)

In this video, the ATO GK3000 inverter uses external voltage analog quantity to control the frequency, thereby achieving the purpose of motor speed regulation.

VFD Programming for Stabilizing Water Pressure in Water Supply System

In this video, we explore how to use ATO's VFD to ensure stable water pressure in your water supply system. We have covered the complete process from wiring, parameter setting and test run.

VFD Frequency Setting to 400Hz

In this video we show you a step-by-step guide on how to set the frequency of ATO's GK3000 VFD to 400Hz.

VFD Basic Troubleshooting Guide

In this video, ATO will show you the vfd basic troubleshooting guide.

4-20mA is as common in analog control systems as 0~10V, and ATO GK3000 series VFDs are also perfectly compatible.

Product reviews
Issues related to single-phase to three-phase VFD
5
Morin
Avatar
4/8/2021 9:06 PM
I was looking at one of your single phase input and output drive. I just want to make sure it has the proper listings for the united states. UL listited?
Was this review helpful? Yes No (0/0)
ATO Responded
Our 1-phase VFD is CE certified, and we provide 18 month warranty.
Very good 1/2hp VFD
5
Anon
Avatar
8/26/2021 12:42 AM
I have a machine 240V/50Hz, can be run at 240v/60Hz. I know the difference in speed is about 20% that will heat up the coil and burn the insolation? What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
We can provide a 1-phase drive that can convert the frequency, but the VFD can be used for motor individually, not for your whole equipment/machine, with direct connection between VFD output terminals and motor input terminals, nothing in between. Also, the motor will be fully controlled (on/off/speed control) via VFD buttons only.
Function of VFD
5
Promac
Avatar
9/10/2021 1:07 AM
Thank you for the instructions. After thinking about it more, what I am looking for is a'Pause for X seconds' button. So I have 1 switch and every time the switch gets pushed, the VFD stops the motor, for X seconds. After X seconds, the motor starts to spin again. Can we do this?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, our VFD does not have the function you mentioned below. If you want the VFD to pause, wait a few seconds before running automatically, you may need to add an external delay relay and PLC programming control to achieve this.
Looking at a vfd for 5 hp motor
5
Felix
Avatar
5/26/2022 11:45 PM
Will this work if i set the motor parameters as on the motor plate for 220v output? I assume that would be as followed: 220V.  60Hz  1.4 amps and 3450 rpm.  If this is correct and this will work please let me know.  Thanks.
Was this review helpful? Yes No (0/0)
ATO Responded
It is recommended to choose a 1hp VFD, so that the power is a little larger than the power of the motor to prevent overload. See on: https://www.ato.com/1hp-vfd
Please share VFD configuration and Installation guide
5
Barrel
Avatar
3/5/2023 7:36 PM
Please share VFD configuration and Installation guide. We want sudden clockwise and anticlockwise movements.
Was this review helpful? Yes No (0/0)
ATO Responded
For VFD configuration and installation, please refer to the manual: https://www.ato.com/Content/doc/ato-gk3000-series-vfd-user-manual.pdf
For sudden clockwise & anticlockwise movements, please refer to the three-wire control mode on page 115 of the manual.
How to solve this error?
5
Beahn
Avatar
4/5/2023 7:39 PM
Whenever I connect to the pc I am getting this type output in my realterm software , I am unable to provide input to the VFD. It continuously shows these irregular values as soon as I connect to the PC. How to solve this error?
Was this review helpful? Yes No (0/0)
ATO Responded
First, the communication configuration P3.09=163 means that the VFD is configured as Modbus RTU protocol.  The data format is 1-8-1 format, no parity, and the baud rate is 9600. But we noticed that the baud rate of the software screenshot below is set to 115200.  The baud rate is obviously different, and there is a problem with the communication parameter setting.
Question about change the configuration
5
Nichaolas
Avatar
9/5/2023 1:38 AM
How to change the configuration from 50 to 60 hz?
Was this review helpful? Yes No (0/0)
ATO Responded
If you want the frequency to reach 60HZ, you can set these parameters:
P01.08=60
P01.10=60,
P01.12 = 60,
P02.04 = 60
and test again.
We need help
5
Lao
Avatar
8/16/2024 1:45 AM
We installed a GK3000. It has not gone well. We need help. How do we increase output voltage? We need a minimum of 208V, we are only getting 195. There is 240 going in. Got it to the “fun” stage several times but no further. Output reads low. We would appreciate any assistance you can provide.
Was this review helpful? Yes No (0/0)
ATO Responded
If your VFD has the number 9000, then you need to set the parameter P8.02=220V.
If your VFD does not have the number 9000, then you need to set the parameter P0.08=220V.
In addition, the output frequency needs to reach the upper limit frequency (rated frequency) for the output voltage to reach 220V.
The factory reset parameter
4
Danica
Avatar
9/14/2024 12:07 AM
What is the factory reset parameter for the ATO GK3000?
Was this review helpful? Yes No (0/0)
ATO Responded
Restore factory settings: If your VFD nameplate has 9000, please set Pd.01=1. If the nameplate does not have 9000, please set parameter P3.01=10.
VFD recommendation
5
Howard
Avatar
4/8/2025 12:08 AM
I have a three-phase, 220-volt, 4-kilowatt table saw that needs to be powered by a 220-volt single-phase power supply. I want to be able to stop it relatively quickly, and may need an external resistor. I hope you can give me a recommendation on this.
Was this review helpful? Yes No (0/0)
ATO Responded
How quickly the motor stops depends on the size of the mechanical inertia. The larger the mechanical inertia, the larger the busbar, the larger the current, and the slower it stops. It is impossible to determine how large a resistor is needed. Our VFD manual defaults to a braking resistor power of 10% of the inverter power for reference.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

1/2 hp VFD, 0.4 kW, 208V - 240V single phase to three phase variable frequency drive, sale by manufacturer directly.

Specification:

BasicsModelGK3000-2S0004
Capacity1/2 hp (0.4 kW)
Shipping weight2 kg
Dimension142*85*110 mm
I/O FeatureRated current3 A
Input voltage1 phase 220~240V AC
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F, Sensorless vector control (SVC), Speed sensor vector control (FVC)
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

400W VFD Single Phase to Three Phase VFD Details

Tips: Variable frequency drive hardware replacement precautions

  1. Replace the IGBT. Measure whether the resistance value of each road is balanced.
  2. Replace the drive board. Need to carefully check whether the plug and socket number is consistent.
  3. Replace the main control board. After replacing the main control board, set the application parameters, motor parameters and protection parameters of VFD.
  4. Replace the PG card. Check whether the terminals are normal. If the motor has a vibration or cannot rotate after replacing the card, need to exchange the A and B phase.
  5. Replace the communication board. Simply check the DIP switch set by VFD hardware station number, and then check that the communication light is normal.
  6. The communication board of some VFD series is an independent CPU. After the replacement, need to upload configuration program.
Product reviews
Issues related to single-phase to three-phase VFD
5
Morin
Avatar
4/8/2021 9:06 PM
I was looking at one of your single phase input and output drive. I just want to make sure it has the proper listings for the united states. UL listited?
Was this review helpful? Yes No (0/0)
ATO Responded
Our 1-phase VFD is CE certified, and we provide 18 month warranty.
Very good 1/2hp VFD
5
Anon
Avatar
8/26/2021 12:42 AM
I have a machine 240V/50Hz, can be run at 240v/60Hz. I know the difference in speed is about 20% that will heat up the coil and burn the insolation? What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
We can provide a 1-phase drive that can convert the frequency, but the VFD can be used for motor individually, not for your whole equipment/machine, with direct connection between VFD output terminals and motor input terminals, nothing in between. Also, the motor will be fully controlled (on/off/speed control) via VFD buttons only.
Function of VFD
5
Promac
Avatar
9/10/2021 1:07 AM
Thank you for the instructions. After thinking about it more, what I am looking for is a'Pause for X seconds' button. So I have 1 switch and every time the switch gets pushed, the VFD stops the motor, for X seconds. After X seconds, the motor starts to spin again. Can we do this?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, our VFD does not have the function you mentioned below. If you want the VFD to pause, wait a few seconds before running automatically, you may need to add an external delay relay and PLC programming control to achieve this.
Looking at a vfd for 5 hp motor
5
Felix
Avatar
5/26/2022 11:45 PM
Will this work if i set the motor parameters as on the motor plate for 220v output? I assume that would be as followed: 220V.  60Hz  1.4 amps and 3450 rpm.  If this is correct and this will work please let me know.  Thanks.
Was this review helpful? Yes No (0/0)
ATO Responded
It is recommended to choose a 1hp VFD, so that the power is a little larger than the power of the motor to prevent overload. See on: https://www.ato.com/1hp-vfd
Please share VFD configuration and Installation guide
5
Barrel
Avatar
3/5/2023 7:36 PM
Please share VFD configuration and Installation guide. We want sudden clockwise and anticlockwise movements.
Was this review helpful? Yes No (0/0)
ATO Responded
For VFD configuration and installation, please refer to the manual: https://www.ato.com/Content/doc/ato-gk3000-series-vfd-user-manual.pdf
For sudden clockwise & anticlockwise movements, please refer to the three-wire control mode on page 115 of the manual.
How to solve this error?
5
Beahn
Avatar
4/5/2023 7:39 PM
Whenever I connect to the pc I am getting this type output in my realterm software , I am unable to provide input to the VFD. It continuously shows these irregular values as soon as I connect to the PC. How to solve this error?
Was this review helpful? Yes No (0/0)
ATO Responded
First, the communication configuration P3.09=163 means that the VFD is configured as Modbus RTU protocol.  The data format is 1-8-1 format, no parity, and the baud rate is 9600. But we noticed that the baud rate of the software screenshot below is set to 115200.  The baud rate is obviously different, and there is a problem with the communication parameter setting.
Question about change the configuration
5
Nichaolas
Avatar
9/5/2023 1:38 AM
How to change the configuration from 50 to 60 hz?
Was this review helpful? Yes No (0/0)
ATO Responded
If you want the frequency to reach 60HZ, you can set these parameters:
P01.08=60
P01.10=60,
P01.12 = 60,
P02.04 = 60
and test again.
We need help
5
Lao
Avatar
8/16/2024 1:45 AM
We installed a GK3000. It has not gone well. We need help. How do we increase output voltage? We need a minimum of 208V, we are only getting 195. There is 240 going in. Got it to the “fun” stage several times but no further. Output reads low. We would appreciate any assistance you can provide.
Was this review helpful? Yes No (0/0)
ATO Responded
If your VFD has the number 9000, then you need to set the parameter P8.02=220V.
If your VFD does not have the number 9000, then you need to set the parameter P0.08=220V.
In addition, the output frequency needs to reach the upper limit frequency (rated frequency) for the output voltage to reach 220V.
The factory reset parameter
4
Danica
Avatar
9/14/2024 12:07 AM
What is the factory reset parameter for the ATO GK3000?
Was this review helpful? Yes No (0/0)
ATO Responded
Restore factory settings: If your VFD nameplate has 9000, please set Pd.01=1. If the nameplate does not have 9000, please set parameter P3.01=10.
VFD recommendation
5
Howard
Avatar
4/8/2025 12:08 AM
I have a three-phase, 220-volt, 4-kilowatt table saw that needs to be powered by a 220-volt single-phase power supply. I want to be able to stop it relatively quickly, and may need an external resistor. I hope you can give me a recommendation on this.
Was this review helpful? Yes No (0/0)
ATO Responded
How quickly the motor stops depends on the size of the mechanical inertia. The larger the mechanical inertia, the larger the busbar, the larger the current, and the slower it stops. It is impossible to determine how large a resistor is needed. Our VFD manual defaults to a braking resistor power of 10% of the inverter power for reference.
Only registered users can write reviews
Customers who bought this item also bought

1 hp VFD, Single Phase to Three Phase VFD

GK3000-2S0007
$159.32
1 hp VFD, convert single phase to three phase for AC motor speed controls, IP20, RS485 enabled, shipping weight 2kg, manufacturer direct sale.

2 hp VFD, Single Phase to Three Phase VFD

GK3000-2S0015
$183.16
2 hp VFD, convert single phase to three phase for AC motor speed controls, 7 amps, IP20, RS485 enabled, manufacturer direct sale.