The provided signal isolator series is a special thermocouple/RTD signal conditioner. The input signal can be thermocouple K/B/S/E type and RTD Pt100, and the output signal can be current 0-20mA/4-20mA and voltage 0-5V/1-5V/0-10V. Low cost signal isolator has pluggable terminals, 13mm thickness and DIN rail installation mounting groove.
SKU: ATO-SIGNI-503H
*
*
*
Free Shipping
Delivery date: 8-12 days

Thermocouple/RTD signal conditioner can input signal of K/B/S/E/PT100 and output signal of 0-20mA/4-20mA/0-5V/1-5V/1-10V/2-10V.

Specification:

ModelATO-SIGNI-1003S
Weight130g
Dimension117.5mm*110mm*13mm
Input signal*thermal resistance

Conventional: Pt100, Cu50
Cu100 Customized: Pt50, Pt200, Pt500, Pt1000

thermocoupleK, E, S, B, J, T, R, N, WRe3-WRe25, WRe5-WRe26
mV signal-120~120mV
Output signal*0~20mA, 4~20mA, 0~5V, 1~5V, 0~10V, 2~10V
Output load resistance

4~20mA, 0~20mA: RL≤550Ω
0~5V, 1~5V, 0~10V, 2~10V: RL≥1MΩ

Transmission accuracySee table below
Isolation strength
(between input/output/power)
1500Vrms (1 min, no spark)
Response time≤500ms (Single-channel)
Temperature drift≤40ppm
EMCEMC conforms to GB/T18268 (IEC 61326-1) requirements for industrial equipment application
Power supply20~35VDC
Power consumption

Single-channel output: ≤1.0W
Double-channel output: ≤1.4W

Operating temperature-20~60℃
Storage temperature-20~60℃
Relative humidity25%~85%
Installation method35mm DIN rail mounting

Transmission accuracy:

Input signal typeRangeAccuracy
TCK/E/J/N/T<300℃±0.3℃
≥300℃±0.1% F.S
S/B/R/WRe-series<500℃±0.5℃
≥500℃±0.1% F.S
RTDPt100/Cu100/Cu50<100℃±0.1℃
≥100℃±0.1% F.S

Dimensional drawing (unit: mm):
Thermocouple rtd signal conditioner dimension
Wiring diagram of Single-channel input and Single-channel output:

Wiring diagram of Single-channel input and Single-channel output

Wiring diagram of Single-channel input and Double-channel output:

Wiring diagram of Single-channel input and Double-channel output

Wiring diagram of Double-channel input and Double-channel output:

Wiring diagram of Double-channel input and Double-channel output

Product reviews
Easy Installation
5
Irabu
Avatar
11/20/2024 2:02 AM
The signal conditioner is very easy to install. It provides a clear wiring diagram and is labeled with thermocouple and RTD sensor input ports, output ports, and power ports. The wiring can be completed quickly according to the instructions.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Thermocouple/RTD signal conditioner can input signal of K/B/S/E/PT100 and output signal of 0-20mA/4-20mA/0-5V/1-5V/1-10V/2-10V.

Specification:

ModelATO-SIGNI-1003S
Weight130g
Dimension117.5mm*110mm*13mm
Input signal*thermal resistance

Conventional: Pt100, Cu50
Cu100 Customized: Pt50, Pt200, Pt500, Pt1000

thermocoupleK, E, S, B, J, T, R, N, WRe3-WRe25, WRe5-WRe26
mV signal-120~120mV
Output signal*0~20mA, 4~20mA, 0~5V, 1~5V, 0~10V, 2~10V
Output load resistance

4~20mA, 0~20mA: RL≤550Ω
0~5V, 1~5V, 0~10V, 2~10V: RL≥1MΩ

Transmission accuracySee table below
Isolation strength
(between input/output/power)
1500Vrms (1 min, no spark)
Response time≤500ms (Single-channel)
Temperature drift≤40ppm
EMCEMC conforms to GB/T18268 (IEC 61326-1) requirements for industrial equipment application
Power supply20~35VDC
Power consumption

Single-channel output: ≤1.0W
Double-channel output: ≤1.4W

Operating temperature-20~60℃
Storage temperature-20~60℃
Relative humidity25%~85%
Installation method35mm DIN rail mounting

Transmission accuracy:

Input signal typeRangeAccuracy
TCK/E/J/N/T<300℃±0.3℃
≥300℃±0.1% F.S
S/B/R/WRe-series<500℃±0.5℃
≥500℃±0.1% F.S
RTDPt100/Cu100/Cu50<100℃±0.1℃
≥100℃±0.1% F.S

Dimensional drawing (unit: mm):
Thermocouple rtd signal conditioner dimension
Wiring diagram of Single-channel input and Single-channel output:

Wiring diagram of Single-channel input and Single-channel output

Wiring diagram of Single-channel input and Double-channel output:

Wiring diagram of Single-channel input and Double-channel output

Wiring diagram of Double-channel input and Double-channel output:

Wiring diagram of Double-channel input and Double-channel output

Product reviews
Easy Installation
5
Irabu
Avatar
11/20/2024 2:02 AM
The signal conditioner is very easy to install. It provides a clear wiring diagram and is labeled with thermocouple and RTD sensor input ports, output ports, and power ports. The wiring can be completed quickly according to the instructions.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

Current Sensor AC/DC 0~1mA/10mA/50mA/0.5A/1A/5A

ATO-CUS-ACDC5
$126.37
Current sensors are AC/DC universal current sensors, with a low current measuring range from milliamp current 1mA to 5A. AC/DC current sensors adopt linear photoelectric isolation or modulation and demodulation principle, fast response, 0.5%FS high accuracy, good stability, small size, light weight, input current terminal connection, DIN rail installation. Isolated current sensors are widely used for AC sine wave current or DC bidirectional current measurement.

Isolated DC Voltage Sensor 10mV to 1000V, Power Supply DC 12V/24V

ATO-VOS-DC1000
$141.96
DC voltage sensor uses modulation and demodulation technology to achieve input/output/power supply isolation. Isolated voltage transducer has measuring range from DC 10mV/50mV/75mV/5V/150V/300V/500V to 1000V, supply voltage DC 12V/24V, accuracy 0.2%FS, output signal 0-5V/0-10V/0-20mA/4-20mA and strong anti-interference capability. DC voltage sensor is widely used for voltage isolated measuring and control, such as electric power, remote monitoring, medical equipment, etc.