Analog Signal Isolator, DC 24V, 4-20mA/0-20mA to 4-20mA/0-10V

$86.77
Analog signal isolator has pluggable terminals, 12.5mm thickness, input/output isolation, fast response, low-power dissipation, low temperature drift. Signal isolator can connect to various types of signal acquisition device and industrial control device, such as PLC, analog acquisition card, VFD, power meter, electricity record meter, DCS, etc.
SKU: ATO-SIGNI-502H
*
*
*
*
Free Shipping
Delivery date: 8-12 days

Signal isolator can convert 4-20mA/0-20mA signal to standard signal or other customized signal.

Specification:

ModelATO-TS-IP
Dimension106.5*12.5*115mm
Input signal4-20mA, 0-10V, 0-20mA
Output signal4-20mA, 0-10V, 0-20mA
Supply voltageDC 24V, acceptable range 20-40V
Distribution voltage≥21V, power ≤30mA
Accuracy±0.1%F.S
Response time10ms
Input impedance25Ω
Load capacity≥800Ω
Power dissipation1 output channel: <1W, 2 output channels: <1.5W
Power-on protectionpower-on impact protection, power-on slow start 20ms
Reverse protectionreverse voltage ≤40V
Temperature drift coefficient≤±1μA/10℃ (typical value)
Isolation withstand voltage1500V AC*1Min (between input, output and power supply)
Output ripple≤5mV (250 ohm load)
Electromagnetic compatibilityIEC61326-1

Dimensional drawing:
analog signal isolator dimensional drawing

Wiring diagram:
Wiring diagram of one-input and two-output analog signal isolator

Tips: How to choose the signal isolator
The signal isolator is installed between two system channels, so the input and output functions shall be determined firstly when selecting an isolator. Meanwhile, the input and output mode (voltage mode, current mode, loop power supply mode) of the isolator shall adapt to the interface mode at the front and back channel. In addition, there are many important parameters also relate to product performance, such as accuracy, power dissipation, noise, insulation strength, bus communication. For example, noise relates with the accuracy, power dissipation relates with the reliability. Users should be careful when selection. All in all, main principle of choosing isolator is application, reliability and cost performance.

Product reviews
Solve the problem of signal interference
5
Juan
Avatar
9/18/2018 3:34 AM
The 110kw power cable and signal line are very close. So the transmitter is disturbed. We used various methods to solve the problem but the signal was still disturbed. Until we use the 4-20mA analog signal isolator with 1 input channel
Was this review helpful? Yes No (0/0)
Signal isolators passed the test
4
Brayden
Avatar
9/20/2018 7:30 PM
The purchased analog signal isolators have passed our company's internal testing, linearity, power consumption, and isolation effects are in line with the requirements. After the signal isolator is disassembled, we could see the circuit board structure is designed reasonably. If the size can be made smaller, the signal isolator will be even more perfect.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Signal isolator can convert 4-20mA/0-20mA signal to standard signal or other customized signal.

Specification:

ModelATO-TS-IP
Dimension106.5*12.5*115mm
Input signal4-20mA, 0-10V, 0-20mA
Output signal4-20mA, 0-10V, 0-20mA
Supply voltageDC 24V, acceptable range 20-40V
Distribution voltage≥21V, power ≤30mA
Accuracy±0.1%F.S
Response time10ms
Input impedance25Ω
Load capacity≥800Ω
Power dissipation1 output channel: <1W, 2 output channels: <1.5W
Power-on protectionpower-on impact protection, power-on slow start 20ms
Reverse protectionreverse voltage ≤40V
Temperature drift coefficient≤±1μA/10℃ (typical value)
Isolation withstand voltage1500V AC*1Min (between input, output and power supply)
Output ripple≤5mV (250 ohm load)
Electromagnetic compatibilityIEC61326-1

Dimensional drawing:
analog signal isolator dimensional drawing

Wiring diagram:
Wiring diagram of one-input and two-output analog signal isolator

Tips: How to choose the signal isolator
The signal isolator is installed between two system channels, so the input and output functions shall be determined firstly when selecting an isolator. Meanwhile, the input and output mode (voltage mode, current mode, loop power supply mode) of the isolator shall adapt to the interface mode at the front and back channel. In addition, there are many important parameters also relate to product performance, such as accuracy, power dissipation, noise, insulation strength, bus communication. For example, noise relates with the accuracy, power dissipation relates with the reliability. Users should be careful when selection. All in all, main principle of choosing isolator is application, reliability and cost performance.

Product reviews
Solve the problem of signal interference
5
Juan
Avatar
9/18/2018 3:34 AM
The 110kw power cable and signal line are very close. So the transmitter is disturbed. We used various methods to solve the problem but the signal was still disturbed. Until we use the 4-20mA analog signal isolator with 1 input channel
Was this review helpful? Yes No (0/0)
Signal isolators passed the test
4
Brayden
Avatar
9/20/2018 7:30 PM
The purchased analog signal isolators have passed our company's internal testing, linearity, power consumption, and isolation effects are in line with the requirements. After the signal isolator is disassembled, we could see the circuit board structure is designed reasonably. If the size can be made smaller, the signal isolator will be even more perfect.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

Manual Tension Controller for Magnetic Powder Clutch/Brake

ATO-TC-001
$101.98
Compact manual tension controller with an output voltage of 24V DC, providing current for excitation powder clutch/brake, hysteresis clutch/brake, etc. Manual tension controller is suitable for slitting machines, printing machines, and other equipment requiring channel tension control or cable processing.