Strain Gauge Load Cell, S type, 5kg/50kg/1000kg/3 ton to 20 ton

$88.41
S type load cell can bear both tension and pressure, with good output symmetry, high accuracy, compact structure and complete specifications. Strain gauge load cell can be applied for batching scale, electronic-mechanical scale, crane scales and other force value measurement and control.
SKU: ATO-LC-S01
*
*
Free Shipping
Delivery date: 6-12 days

After purchasing one ATO load cell, you can buy a special digital panel meter to obtain readings directly, or buy a transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4-20mA.

Note: The load cell cannot be connected to both the transmitter and the controller at the same time — only one can be selected.

Tension and compression load cells have capacity range from 5kg, 50kg, 300kg, 1000kg, 3 ton to 20 ton. Strain gauge load cell capacity can be customized according to customer requirements.

Specification

ModelATO-LCS-TJL-1
Shipping Weight2~15kg
Capacity Range *5 kg~20 ton
Matched Display ControllerATO-TY5DA3 (Click it to the controller page)
Matched TransmitterATO-NTB3K (Click it to the transmitter page)
Accuracy0.02~0.03%F.S (linearity + hysteresis + repeatability)
Sensitivity2.0±0.1mV/V
Creep±0.02~±0.03%F.S/30min
Zero Output±1%F.S
Temperature Effect on Zero±0.02~±0.03%F.S/10℃
Temperature Effect on Output±0.02~±0.03%F.S/10℃
Operating Temperature-20℃~+65℃
Input Impedance380±10Ω
Output Impedance350±3Ω
Insulation Resistance≥5000MΩ
Safety Overload150%F.S
Bridge Voltage (excitation voltage)DC 10V
MaterialAlloy steel (Stainless steel load cell can be customizable, contact us for further communication. MOQ: 5pcs)
Protection ClassIP67 (except 5 kg model)
Cable Length3m (<5 ton), 6m (≥5 ton)
WiringEXC+: Red, EXC-: Black, SIG+: Green, SIG-: White
Accessories *A pair of rings (only for capacity≤1000kg)


Feature

Tension load cell s type 50kg to 20 ton feature

  • S-Type Sensor: Made from 42Cr alloy steel, it offers high strength and excellent fatigue resistance, capable of measuring both tension and compression.
  • High Precision Strain Gauge: Equipped with a high-quality strain gauge to simultaneously compensate for temperature and deflection, ensuring stable performance.
  • Waterproof Connector: Features a six-corner waterproof connector with an elastic sleeve to prevent cable pull-out and improve durability.
  • Standard Thread Holes: Comes with standard threaded holes at both ends, ensuring easy and worry-free installation.

Dimension

Tension load cell S type 50kg to 20 ton dimension

CapacityDimension (mm)
ABCM
5~50kg645112.7M8
100~700kg765119.1M12
1~1.5 ton765125.4M12
2~5 ton1087625.4M20
7.5~10 ton17812751M30
20 ton18814060M36*3


Wiring Method

Load cell wiring method

Application

Tension load cell s type 50kg to 20 ton application

Tips: How to select load cells?
The selection of the load cell quantity is decided according to the application of the electronic weighing instrument, the number of points required to be supported of the scale (the number of points should be determined according to the principle that the geometric gravity center of the scale should coincide with the practical gravity center). Generally, the quantity of the supporting points is exactly the quantity of the load cell. However, as to some special scales, such as the electronic crane scale, only one sensor will be employed. Some electronic-mechanical scales should be decided of the load cell quantity according to the practical conditions.
The selection of the load cell range can be determined according to the comprehensive assessment of the maximum weighing value of the scale, the quantity of the load cell, the dead weight of the scale, the possible generated maximum eccentric load, dynamic load and other factors. Generally, if the measuring range of the load cell is close to the load distributed to each sensor, the weighing accuracy is high. However, in the practical operation, because the load exerted to the sensor still includes the scale dead weight, tare weight, eccentric load and vibratory impulse and so on in addition to the weighed products, factors of several aspects should be considered in selecting the load cell range, so as to ensure the safety and service life of the load cell.

In this video, ATO will show you how to wire a strain gauge load cell with a display controller.

Low Profile Micro Compression Button Load Cell 100kg
This video introduces the specs, design features and applications of a low profile miniature button load cell DYHW-110 that's intended for compression force measurement. The maximum load capacity it can bear is 100kg. It can achieve 0.5%F.S accuracy with 150%F.S safety overload and temperature compensation.

Shear Beam Load Cell | Single & Double-Ended, Weighbridge Load Cells

The shear beam load cell is a common load cell. Its working principle is based on the deformation of the elastomer when it is acted upon by an external force. This deformation will cause the resistance of the elastomer to change, thereby achieving the measurement of the external force. It is typically used to measure forces in the small to medium range and its working principle is based on the shear effect of elastically deforming materials. This type of force measuring element is usually made of metal or polymer materials. Because of its high elastic modulus and shear modulus, it can produce stable shear deformation when subjected to external forces.

How to Ensure the Accuracy of Your Weighing System?

This video describes five factors that affect the accuracy of a weighing system and provides recommendations for selecting, installing, and operating the system to handle these factors.

Load Cell Transmitter 4~20mA Output Calibration

This video demonstrates how to calibrate the 4~20mA output. The 0~10V is also calibrated in the same way.

How Does PLC Read Data of Load Cell Transmitter?

In this video, it shows how PLC reads data from sensor transmitter. This system mainly consists of PLC, ATO load cell transmitter, ATO load cell, 24VDC power supply, personal computer, etc.

Product reviews
Good
5
Kraus
Avatar
5/18/2018 1:18 AM
S type load cell has been installed, good sensitivity and stability.
Was this review helpful? Yes No (0/0)
Great sensor
5
hydrodave
Avatar
3/18/2019 3:11 AM
This 1000kg S type strain gauge load cell is performing well in the material testing machine. It is precise, stable, and easy installation. A good sensor.
Was this review helpful? Yes No (0/0)
ATO load cell is perfect for my equipment.
5
Jesus
Avatar
11/5/2019 6:41 PM
I want to buy a 500kg s type load cell. After confirming with the staff, I am told that the ATO-LC-S01 is exactly the same dimension as my broken load cell. Since my accessories are still available, there is no need to buy the rings. The received load cell looks very solid, and it's really heavier than the original one. I think it's very perfect that it can be installed directly in the equipment. Now it has been running for some days, all aspects of performance are better than the original.
Was this review helpful? Yes No (0/0)
Deflection at full load
5
Matthew
Avatar
8/3/2021 3:25 PM
How much does this cell deflect at the rated full compression load?
Was this review helpful? Yes No (0/0)
ATO Responded
The deflection of this unit is about 0.3mm.
Questions about load cell
5
Jamyl
Avatar
12/21/2021 12:27 AM
What happens if the load exceeds 100%F.S? For example, can I operate the cell at 125%F.S? Or 150%?
Was this review helpful? Yes No (0/0)
ATO Responded
Within 150% of the range, the components inside the sensor may be damaged, and more than 150% of the sensor capacity, may cause deformation.
Output
5
Nicolas
Avatar
1/27/2022 9:11 AM
What is the output when the cell is on compression?  10V
What is the output when the cell is on Tension? -10V ?
Was this review helpful? Yes No (0/0)
ATO Responded
The output is a millivolt voltage signal.
We received the first load cell and display controller with software.
5
Sarah
Avatar
5/29/2022 9:35 PM
We received the first load cell and display controller with software. I need some help installing them. Can you please send me a translated copy of the manual for the controller and software in English? All I have is in Chinese.
Was this review helpful? Yes No (0/0)
ATO Responded
Please check the attached translated copy of the manual for the controller and software.
Note that when you install the software, you can first modify the computer language to Simplified Chinese (this will not modify the current language of the computer) according to the attached notice document, and then install the software, which can avoid system errors and install the software smoothly.
If you have any further questions, please feel free to contact me.
I have a load cell, and have a question about it.
5
Tyler
Avatar
7/27/2022 7:15 PM
Is there a side of the unit that needs to be on top, and the other side needs to be on bottom? Or is the unit okay with being installed in both orientations?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, this load cell can be fixed on one end (top or bottom) or two ends (both top and bottom), either is ok. It must be noted that when fixing the screws, there should be a little gap between the screws and the ring surface.
Press application
5
Dario
Avatar
8/6/2022 3:03 AM
Good morning
Could this cell work for a press that has 10ms of impact?
Thank you
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, it can't.
Tension Flexion
4
Connor
Avatar
10/10/2022 7:21 PM
How much will the load cell stretch when at 100 FS?
Was this review helpful? Yes No (0/0)
ATO Responded
Different capacity range with different deformation. eg. For 300kg capacity, the deformation is 0.02mm. For 10 ton capacity, the deformation is 0.2mm.
Data Sheet
5
Emmanuel Junior
Avatar
1/16/2023 1:17 PM
I got the S-type Load Cell installed. I need a data sheet to deduce a linear expression for my configuration. You may forward that to my email. Thank you
Was this review helpful? Yes No (0/0)
ATO Responded
OK, the data sheet will be emailed to you.
Datasheet
4
Emmanuel Junior
Avatar
1/16/2023 2:13 PM
I bought and installed an s type load cell from Ato. I need a data sheet for the calibration and configuration of my setup. I am measuring pressure in PSI; I will therefore need a datasheet that correlates mV and Psi. Thank you.
Was this review helpful? Yes No (0/0)
ATO Responded
OK, the data sheet will be emailed to you.
Calibration problems with load cells
5
Huin
Avatar
3/3/2023 12:01 AM
I tried all options as you mentioned above email as well as other systems. After all, it always displays " Error 1". And for calibration, I always follow two steps calibration approach as mentioned into video. However, it displays Error 1. I don't know the reason exactly. Thanks
Was this review helpful? Yes No (0/0)
ATO Responded
1. For a 5 ton range load cell, you need at least 500Kg of weight to do the calibration work. But with the video you provided earlier, we can't see what the calibration weight is? May I ask what objects are you using as calibration weights? What is the specific weight in kg that you can use for calibration?
2. Before the calibration work, please confirm that the load cell and the controller are wired correctly, and prepare a weight of 500Kg. If you cannot provide a 500Kg weight object for calibration, please prepare a 50Kg calibration weight and use the following coefficient calibration method for calibration.
3. Please follow the linked operation video to recalibrate using the coefficient calibration method.

Note:
1. Please set the display unit to Kg, set the sensor range parameter F-r to 5000Kg, and do Not set the decimal point.
2. Calibrate according to the correction factor method in the video, only put in the calibration weight 50Kg.

Please check the link for the video: https://we.tl/t-FCnY8FlA0j
Some questions of load cell
5
Aubren
Avatar
7/12/2024 3:22 AM
I've helped my daughter calculate the drag on spheres of various sizes and I think our range will be 0-20 N where we're interested in capturing things in the 0-5 N range.
I have a question.  When you reference "zero output" in the specs as 1% full scale, does that mean that your error around zero is 1% full scale? So a 5 kg scale would have an error of 0.05 kg around zero. I've been looking at the various s-type load cells.
https://www.ato.com/tension-load-cell-s-type-50kg-to-20-ton
https://www.ato.com/tension-load-cell-s-type-5kg-to-500kg
https://www.ato.com/micro-load-cell-s-type-1kg-to-50kg
https://www.ato.com/micro-load-cell-s-type-0kg-to-200kg
I'm curious if you might have anything on the scratch and dent shelf, or return shelf, or could possibly provide an educational discount. I don't think we really meet the listed requirements for the educational discount. This work is performed at home. We could certainly write a review after all is said and done. My daughter will also make a poster where we could acknowledge ATO as a contributor.
Was this review helpful? Yes No (0/0)
ATO Responded
"Zero output" is the zero point error of the no-load output, and the zero point error can be ignored by tare. The accuracy of the S-type load cell is about 0.5% when it is 0-5KG, so the error theory of 5Kg is 0.025Kg. However, this error is actually related to the accuracy of the acquisition system and display used.
About the reading issue
5
Lunes
Avatar
4/21/2026 1:55 AM
I am using an ATO-LCS-TJL-1 1000kg load cell and an ATO-NTB3K weight transmitter. I input 10V to the weight transmitter and tried testing the load cell output with 5 lb, 10 lb, and 15 lb weights. Each time a weight is added, the reading has an error of approximately 1-2kg. For example, I added a weight of approximately 45 lbs; theoretically, the reading should be close to 20kg, but after converting the voltage to kg, the reading is approximately 22kg.
Was this review helpful? Yes No (0/0)
ATO Responded
The ATO-LCS-TJL-1 1000kg load cell you purchased has an accuracy of 0.1%FS. The load weight on the load cell is only 20kg, and the field installation method will also have a slight impact on the reading. We believe that an error of 1-2 kg is within the normal range, and you can continue to use it. We suggest you increase the load weight and then check if the error is normal.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

After purchasing one ATO load cell, you can buy a special digital panel meter to obtain readings directly, or buy a transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4-20mA.

Note: The load cell cannot be connected to both the transmitter and the controller at the same time — only one can be selected.

Tension and compression load cells have capacity range from 5kg, 50kg, 300kg, 1000kg, 3 ton to 20 ton. Strain gauge load cell capacity can be customized according to customer requirements.

Specification

ModelATO-LCS-TJL-1
Shipping Weight2~15kg
Capacity Range *5 kg~20 ton
Matched Display ControllerATO-TY5DA3 (Click it to the controller page)
Matched TransmitterATO-NTB3K (Click it to the transmitter page)
Accuracy0.02~0.03%F.S (linearity + hysteresis + repeatability)
Sensitivity2.0±0.1mV/V
Creep±0.02~±0.03%F.S/30min
Zero Output±1%F.S
Temperature Effect on Zero±0.02~±0.03%F.S/10℃
Temperature Effect on Output±0.02~±0.03%F.S/10℃
Operating Temperature-20℃~+65℃
Input Impedance380±10Ω
Output Impedance350±3Ω
Insulation Resistance≥5000MΩ
Safety Overload150%F.S
Bridge Voltage (excitation voltage)DC 10V
MaterialAlloy steel (Stainless steel load cell can be customizable, contact us for further communication. MOQ: 5pcs)
Protection ClassIP67 (except 5 kg model)
Cable Length3m (<5 ton), 6m (≥5 ton)
WiringEXC+: Red, EXC-: Black, SIG+: Green, SIG-: White
Accessories *A pair of rings (only for capacity≤1000kg)


Feature

Tension load cell s type 50kg to 20 ton feature

  • S-Type Sensor: Made from 42Cr alloy steel, it offers high strength and excellent fatigue resistance, capable of measuring both tension and compression.
  • High Precision Strain Gauge: Equipped with a high-quality strain gauge to simultaneously compensate for temperature and deflection, ensuring stable performance.
  • Waterproof Connector: Features a six-corner waterproof connector with an elastic sleeve to prevent cable pull-out and improve durability.
  • Standard Thread Holes: Comes with standard threaded holes at both ends, ensuring easy and worry-free installation.

Dimension

Tension load cell S type 50kg to 20 ton dimension

CapacityDimension (mm)
ABCM
5~50kg645112.7M8
100~700kg765119.1M12
1~1.5 ton765125.4M12
2~5 ton1087625.4M20
7.5~10 ton17812751M30
20 ton18814060M36*3


Wiring Method

Load cell wiring method

Application

Tension load cell s type 50kg to 20 ton application

Tips: How to select load cells?
The selection of the load cell quantity is decided according to the application of the electronic weighing instrument, the number of points required to be supported of the scale (the number of points should be determined according to the principle that the geometric gravity center of the scale should coincide with the practical gravity center). Generally, the quantity of the supporting points is exactly the quantity of the load cell. However, as to some special scales, such as the electronic crane scale, only one sensor will be employed. Some electronic-mechanical scales should be decided of the load cell quantity according to the practical conditions.
The selection of the load cell range can be determined according to the comprehensive assessment of the maximum weighing value of the scale, the quantity of the load cell, the dead weight of the scale, the possible generated maximum eccentric load, dynamic load and other factors. Generally, if the measuring range of the load cell is close to the load distributed to each sensor, the weighing accuracy is high. However, in the practical operation, because the load exerted to the sensor still includes the scale dead weight, tare weight, eccentric load and vibratory impulse and so on in addition to the weighed products, factors of several aspects should be considered in selecting the load cell range, so as to ensure the safety and service life of the load cell.

Product reviews
Good
5
Kraus
Avatar
5/18/2018 1:18 AM
S type load cell has been installed, good sensitivity and stability.
Was this review helpful? Yes No (0/0)
Great sensor
5
hydrodave
Avatar
3/18/2019 3:11 AM
This 1000kg S type strain gauge load cell is performing well in the material testing machine. It is precise, stable, and easy installation. A good sensor.
Was this review helpful? Yes No (0/0)
ATO load cell is perfect for my equipment.
5
Jesus
Avatar
11/5/2019 6:41 PM
I want to buy a 500kg s type load cell. After confirming with the staff, I am told that the ATO-LC-S01 is exactly the same dimension as my broken load cell. Since my accessories are still available, there is no need to buy the rings. The received load cell looks very solid, and it's really heavier than the original one. I think it's very perfect that it can be installed directly in the equipment. Now it has been running for some days, all aspects of performance are better than the original.
Was this review helpful? Yes No (0/0)
Deflection at full load
5
Matthew
Avatar
8/3/2021 3:25 PM
How much does this cell deflect at the rated full compression load?
Was this review helpful? Yes No (0/0)
ATO Responded
The deflection of this unit is about 0.3mm.
Questions about load cell
5
Jamyl
Avatar
12/21/2021 12:27 AM
What happens if the load exceeds 100%F.S? For example, can I operate the cell at 125%F.S? Or 150%?
Was this review helpful? Yes No (0/0)
ATO Responded
Within 150% of the range, the components inside the sensor may be damaged, and more than 150% of the sensor capacity, may cause deformation.
Output
5
Nicolas
Avatar
1/27/2022 9:11 AM
What is the output when the cell is on compression?  10V
What is the output when the cell is on Tension? -10V ?
Was this review helpful? Yes No (0/0)
ATO Responded
The output is a millivolt voltage signal.
We received the first load cell and display controller with software.
5
Sarah
Avatar
5/29/2022 9:35 PM
We received the first load cell and display controller with software. I need some help installing them. Can you please send me a translated copy of the manual for the controller and software in English? All I have is in Chinese.
Was this review helpful? Yes No (0/0)
ATO Responded
Please check the attached translated copy of the manual for the controller and software.
Note that when you install the software, you can first modify the computer language to Simplified Chinese (this will not modify the current language of the computer) according to the attached notice document, and then install the software, which can avoid system errors and install the software smoothly.
If you have any further questions, please feel free to contact me.
I have a load cell, and have a question about it.
5
Tyler
Avatar
7/27/2022 7:15 PM
Is there a side of the unit that needs to be on top, and the other side needs to be on bottom? Or is the unit okay with being installed in both orientations?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, this load cell can be fixed on one end (top or bottom) or two ends (both top and bottom), either is ok. It must be noted that when fixing the screws, there should be a little gap between the screws and the ring surface.
Press application
5
Dario
Avatar
8/6/2022 3:03 AM
Good morning
Could this cell work for a press that has 10ms of impact?
Thank you
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, it can't.
Tension Flexion
4
Connor
Avatar
10/10/2022 7:21 PM
How much will the load cell stretch when at 100 FS?
Was this review helpful? Yes No (0/0)
ATO Responded
Different capacity range with different deformation. eg. For 300kg capacity, the deformation is 0.02mm. For 10 ton capacity, the deformation is 0.2mm.
Data Sheet
5
Emmanuel Junior
Avatar
1/16/2023 1:17 PM
I got the S-type Load Cell installed. I need a data sheet to deduce a linear expression for my configuration. You may forward that to my email. Thank you
Was this review helpful? Yes No (0/0)
ATO Responded
OK, the data sheet will be emailed to you.
Datasheet
4
Emmanuel Junior
Avatar
1/16/2023 2:13 PM
I bought and installed an s type load cell from Ato. I need a data sheet for the calibration and configuration of my setup. I am measuring pressure in PSI; I will therefore need a datasheet that correlates mV and Psi. Thank you.
Was this review helpful? Yes No (0/0)
ATO Responded
OK, the data sheet will be emailed to you.
Calibration problems with load cells
5
Huin
Avatar
3/3/2023 12:01 AM
I tried all options as you mentioned above email as well as other systems. After all, it always displays " Error 1". And for calibration, I always follow two steps calibration approach as mentioned into video. However, it displays Error 1. I don't know the reason exactly. Thanks
Was this review helpful? Yes No (0/0)
ATO Responded
1. For a 5 ton range load cell, you need at least 500Kg of weight to do the calibration work. But with the video you provided earlier, we can't see what the calibration weight is? May I ask what objects are you using as calibration weights? What is the specific weight in kg that you can use for calibration?
2. Before the calibration work, please confirm that the load cell and the controller are wired correctly, and prepare a weight of 500Kg. If you cannot provide a 500Kg weight object for calibration, please prepare a 50Kg calibration weight and use the following coefficient calibration method for calibration.
3. Please follow the linked operation video to recalibrate using the coefficient calibration method.

Note:
1. Please set the display unit to Kg, set the sensor range parameter F-r to 5000Kg, and do Not set the decimal point.
2. Calibrate according to the correction factor method in the video, only put in the calibration weight 50Kg.

Please check the link for the video: https://we.tl/t-FCnY8FlA0j
Some questions of load cell
5
Aubren
Avatar
7/12/2024 3:22 AM
I've helped my daughter calculate the drag on spheres of various sizes and I think our range will be 0-20 N where we're interested in capturing things in the 0-5 N range.
I have a question.  When you reference "zero output" in the specs as 1% full scale, does that mean that your error around zero is 1% full scale? So a 5 kg scale would have an error of 0.05 kg around zero. I've been looking at the various s-type load cells.
https://www.ato.com/tension-load-cell-s-type-50kg-to-20-ton
https://www.ato.com/tension-load-cell-s-type-5kg-to-500kg
https://www.ato.com/micro-load-cell-s-type-1kg-to-50kg
https://www.ato.com/micro-load-cell-s-type-0kg-to-200kg
I'm curious if you might have anything on the scratch and dent shelf, or return shelf, or could possibly provide an educational discount. I don't think we really meet the listed requirements for the educational discount. This work is performed at home. We could certainly write a review after all is said and done. My daughter will also make a poster where we could acknowledge ATO as a contributor.
Was this review helpful? Yes No (0/0)
ATO Responded
"Zero output" is the zero point error of the no-load output, and the zero point error can be ignored by tare. The accuracy of the S-type load cell is about 0.5% when it is 0-5KG, so the error theory of 5Kg is 0.025Kg. However, this error is actually related to the accuracy of the acquisition system and display used.
About the reading issue
5
Lunes
Avatar
4/21/2026 1:55 AM
I am using an ATO-LCS-TJL-1 1000kg load cell and an ATO-NTB3K weight transmitter. I input 10V to the weight transmitter and tried testing the load cell output with 5 lb, 10 lb, and 15 lb weights. Each time a weight is added, the reading has an error of approximately 1-2kg. For example, I added a weight of approximately 45 lbs; theoretically, the reading should be close to 20kg, but after converting the voltage to kg, the reading is approximately 22kg.
Was this review helpful? Yes No (0/0)
ATO Responded
The ATO-LCS-TJL-1 1000kg load cell you purchased has an accuracy of 0.1%FS. The load weight on the load cell is only 20kg, and the field installation method will also have a slight impact on the reading. We believe that an error of 1-2 kg is within the normal range, and you can continue to use it. We suggest you increase the load weight and then check if the error is normal.
Only registered users can write reviews
Customers who bought this item also bought

Load Cell Transmitter, Output 0-5V/0-10V/4-20mA

ATO-LCTR-OA
$81.27
Load cell transmitter is made of aluminum alloy, output standard signal 0-5V/0-10V/4-20mA, has linear compensation, humidity compensation, external zero debugging, external span debugging, input overload protection and output short circuit protection functions.

5 Digit Display Controller for Load Cells

ATO-DPM-LC5D
$210.80
Digital panel meter can cooperate with load cells, force sensors and weighing sensors, two outputs for data comparison, digital panel meter can display gross, net, peak and valley value alternately.

Digital Load Cell Amplifier, Output 4-20mA/0-10V/RS485

ATO-LCTR-OAR
$109.85
High precision load cell amplifier has a 6 digit LED display, output signal 4-20mA/ 0-5V/ 0-10V/ RS485. There are 3 keys for parameter settings. Digital load cell amplifier can be calibrated on-line by its 3 keys. The setting parameters include zero, capacity, communication rate, division value, decimal digits, etc.

Load Cell Junction Box for Scales, 2/3/4/6/8/10 Inlets to 1 Outlet

ATO-LCBOX-10I
$66.67
Multi-channel load cell junction box has 2/3/4/6/8/10 inlets and 1 outlet, aluminum alloy casing, good anti-interference, special for waterproof sealing joint, waterproof and dustproof rubber gasket for cover, easy to assemble and debug. Each channel can be adjusted balance to prevent damage to the sensor caused by inductive lightning and surge signals.

Strain Gauge Load Cell, S type, 5kg/20kg/30kg/500kg to 7 ton

ATO-LC-S02
$82.59
S type load cell can bear both tension and pressure, with overload protection device, good output symmetry, high accuracy, compact structure and complete specifications. Strain gauge load cell can be applied for batching scale, electronic-mechanical scale, crane scales, automatic weighing instrument and other force value measurement and control.