Load cell amplifier has on-line calibration functions, output standard signal 4-20mA/0-5V/0-10V/RS485.
Specification:
| Model | ATO-S-LCTR-DY610 |
| Accuracy | ±0.2%FS ±1 byte |
| Input signal | 0~±20mV |
| Excitation voltage for load cell | DC 5V |
| Output signal * | DC 4-20mA, DC 0-5V, DC 0-10V, RS485 (Modbus-RTU), 4-20mA & RS485, 0-5V & RS485, 0-10V & RS485 |
| Sampling rate | 60 times/s, 120 times/s |
| Power supply | DC 12-30V |
| Power consumption | <1W |
| Display | 6 digit red LED, -99999~999999 |
Digital load cell Amplifier dimension drawing (unit: mm):
Load cell Amplifier wiring diagram:
Product reviews
Load cell amplifier with digital display
Christian C
7/22/2019 2:00 AM
The load cell amplifier with digital display is a very good product. It can be used as a load cell indicator for reading the weight values. So I save the money on buying another digital indicator. After setting parameters, I use a standard weight of 200g to test it, and the measured data is very accurate.
Was this review helpful? (1/0)
Peak function of digital load cell amplifier
Crisin
4/27/2021 9:30 PM
Hello, I was watching the video for the 6 digit display controller for load cells and did not see what the peak function is. Is this used to measure the peak force applied to the load cell?
Was this review helpful? (1/0)
Display controller of digital load cell
Regina
5/6/2021 12:11 AM
What is the output of the 6 digit display controller for digital load cells, is it newtons?
Was this review helpful? (0/0)
We have some other questions.
Hsdallas
12/24/2021 12:58 AM
Thank you for all the answers. We do have some additional questions.
Assuming the use of ATO-LCTR-DY510, 0-10V and based on the load cell mentioned in the previous mail (FMZK 10kg):
http://www.forsentek.com/down/miniature load cell FMZK.pdf
The load cells have quite a big zero balance (±0.1mV/V). Does the amplifier have enough adjusting range to create an output voltage of 0V at zero load?
The load cells have a rather low output signal (about 1.0mV/V). Giving the fact that when a load cell is loaded with 7kg, is it possible to reach a maximum output voltage of 10V? Even when zero balancing is taken into account?
About the 200mA current, maybe I should rephrase it. 200mA is the maximum current that we can supply to the amplifier. Is the supply current of the amplifier (with a load cell) below 200mA?
Best regards.
Assuming the use of ATO-LCTR-DY510, 0-10V and based on the load cell mentioned in the previous mail (FMZK 10kg):
http://www.forsentek.com/down/miniature load cell FMZK.pdf
The load cells have quite a big zero balance (±0.1mV/V). Does the amplifier have enough adjusting range to create an output voltage of 0V at zero load?
The load cells have a rather low output signal (about 1.0mV/V). Giving the fact that when a load cell is loaded with 7kg, is it possible to reach a maximum output voltage of 10V? Even when zero balancing is taken into account?
About the 200mA current, maybe I should rephrase it. 200mA is the maximum current that we can supply to the amplifier. Is the supply current of the amplifier (with a load cell) below 200mA?
Best regards.
Was this review helpful? (1/0)
I bought a Digital load amplifier 4-20mA.
Bruce
5/24/2022 7:20 PM
I bought a Digital load amplifier 4-20mA. I'm unable to get any output signal from the digital load cell amplifier. The signal is stuck between 32-33mA.
Was this review helpful? (0/0)
Cannot I exceed the 2Nm of torque correct?
Shelby
5/26/2022 2:54 AM
In the documentation, you state that the “total load range 1 / 10 to remain stable”. If I have 20Nm Torque transducer, Cannot I exceed the 2Nm of torque correct?
Was this review helpful? (0/0)
Questions about load cell amplifier
Fred
3/2/2023 11:53 PM
I have a couple of ATO-LCTR-OAR units. How can I tell which ones have Voltage output or Current output and/or RS485 output?
Was this review helpful? (0/0)
Can we use this Digital Loadcell Amplifier for our load cell?
Zainul
3/27/2023 7:41 PM
We need a load cell signal conditioner for our dynamometer. We want to confirm with you if we can use this Digital Loadcell Amplifier for our load cell.
Was this review helpful? (0/0)
I want to get a CAD model of load cell amplifier
rabbie
6/13/2023 9:45 PM
We just purchased the following items and I'm hoping I can get a CAD model of each.
ATO-LC-TC04 - 20 Ton Version
SKU: ATO-LCTR-OAR
ATO-LC-TC04 - 20 Ton Version
SKU: ATO-LCTR-OAR
Was this review helpful? (0/0)
Modbus Mapping
Tom
7/10/2023 2:45 AM
We are using the ATO-LCTR-OAR with Modbus output. We read the Torque output of a torque sensor, and can read it fine from the given registers. We'd like to change the baud rate from 9600 to 38400, can it be done via the button interface?
Was this review helpful? (0/0)
Why is load cell amplifier FFs result is the same?
reut
7/17/2023 2:36 AM
I use the Modbus RS485 interface at 9600,8,1 to read data.
The amplifier working fine but now only reads FFs.
So I verified with Commix1.4 terminal with different baud rates, re-entered all parameters of the amplifier, and all data FFs is the same result. Please tell me why.
The amplifier working fine but now only reads FFs.
So I verified with Commix1.4 terminal with different baud rates, re-entered all parameters of the amplifier, and all data FFs is the same result. Please tell me why.
Was this review helpful? (0/0)
Is it possible the amplifier has lost its settings and needs to be reset?
yohya
7/17/2023 8:44 PM
Thanks for responding.
All Modbus RS485 data read back is all FFs and does not change when force is applied to the load cell. The amplifier was working fine for a week until it suddenly started returning all FFs.
Nothing has changed with the software or connection. The front digital displays the correct reading. The RS485 parameters seemed to be correct otherwise the amplifier would not respond.
Is it possible the amplifier has lost its settings and needs to be reset? The manual indicates function code 0 x 05 supports "restore factory settings" but does not give instructions.
All Modbus RS485 data read back is all FFs and does not change when force is applied to the load cell. The amplifier was working fine for a week until it suddenly started returning all FFs.
Nothing has changed with the software or connection. The front digital displays the correct reading. The RS485 parameters seemed to be correct otherwise the amplifier would not respond.
Is it possible the amplifier has lost its settings and needs to be reset? The manual indicates function code 0 x 05 supports "restore factory settings" but does not give instructions.
Was this review helpful? (0/0)
Calibration of load cell
avery
7/17/2023 8:54 PM
Can you please assist me? I am unable to get a good calibration.
We have purchased: ATO-LCTR-OAR (MODEL 610-A1) Load cell Amplifier,
ATO-LC-S01 *(10Kn) S Type Load cell
I connected the load cell and powered the transmitter
I set Parameter 01 SL (zero point) at 00000
I set Parameter 02 SH (load calibration value) at 107.23
I placed 107.23 Kilograms of calibration weight on S type load cell
I set Parameter 04 SD (decimal place) at 2
I removed the calibration weight
I exited programming.
When I place the calibration weight on the load cell the display now shows me 466.14 instead of 107.23. What am I missing in programming?
We have purchased: ATO-LCTR-OAR (MODEL 610-A1) Load cell Amplifier,
ATO-LC-S01 *(10Kn) S Type Load cell
I connected the load cell and powered the transmitter
I set Parameter 01 SL (zero point) at 00000
I set Parameter 02 SH (load calibration value) at 107.23
I placed 107.23 Kilograms of calibration weight on S type load cell
I set Parameter 04 SD (decimal place) at 2
I removed the calibration weight
I exited programming.
When I place the calibration weight on the load cell the display now shows me 466.14 instead of 107.23. What am I missing in programming?
Was this review helpful? (0/0)
Modbus register for baud rate
Tom
7/27/2023 12:00 AM
Plase confirm the address for Modbus register where baud rate is changed. We use the map as supplied in the downloads, but the data registers we read does not seem to correspond, and we do not want to write to a wrong register.
Was this review helpful? (0/0)
What is the maximum load capacity (in newtons) of the load cell?
Grace
8/1/2023 1:24 PM
Was there a set capacity, or does it change based on the setting? How do you change it?
Was this review helpful? (0/0)
What should I do?
Shaun
8/3/2023 12:54 AM
I recently purchased a digital load cell amplifier with output signal 0-5V & RS485. I have a Siemens S7-1200 PLC with a Communication Board CB 1241, allowing RS485 communication. Can I get assistance in determining what specific hardware I need for wiring the A B output of the amplifier to the connections of the CB 1241?
Was this review helpful? (0/0)
How to calibrate on the negative side?
Phill
10/17/2023 1:25 AM
I need to calibrate my ato load cell and amplifier in tension rather than compression. I have followed the steps online but those all pertain to a mass loading the cell in compression, but i need the opposite. Can you instruct me how I can calibrate on the negative (tension) side?
Was this review helpful? (0/0)
A couple questions
Logan
11/6/2023 12:11 AM
I am running into problems with the 0-10V output from the 610-A1 box. Specifically at higher loads the voltage entirely drops out. Do you know why this would happen?
A couple other smaller questions:
How is the transmitting range affected by multiple summed load cells?
Is there a delay on the 0-10V output from the 610-A1?
A couple other smaller questions:
How is the transmitting range affected by multiple summed load cells?
Is there a delay on the 0-10V output from the 610-A1?
Was this review helpful? (0/0)
How do I debug it?
jason
11/8/2023 7:48 PM
This setup is measuring the force applied by an arbor press, so I’d consider the speed to be slow and the force applied very gradual. In short, we are using these load cells underneath a pressure plate on an arbor press to estimate press force.
Was this review helpful? (0/0)
How to fix it?
Lucas
11/16/2023 2:12 AM
The indicator doesn't display anything unique. When it get power it display normal. When a weight is loaded its value remains displaying zero, there is no even a tiny fluctuations on the display when a weight is put on the scale. We have crosscheck the problem is not on the loadcell, we calibrated it, we even tried reset procedure you told recently. Despite all effort it remains dysfunctional. How to fix it?
Was this review helpful? (0/0)
Digital Load Cell Amplifier
Henry
11/23/2023 11:52 PM
The full capacity of the scale is 50kg. So the sample weight is well above the minimum requirement. I don't think it is related with calibration because it was initially calibrated and working properly before this happen.
Was this review helpful? (0/0)
Digital Load Cell Amplifier
Levis
11/27/2023 8:27 PM
Do I need to buy wires for the digital load cell amplifier, output 4-20mA/0-10V/RS485? I'm wondering if it is included with the amplifier. If not I need to buy one I guess.
Was this review helpful? (0/0)
Excellent Load Cell Amplifier and Customer Service
Amanda
12/5/2023 10:03 AM
Initially, I had many issues calibrating the load cell amplifier (0-10 V, RS-485), but ATO worked with me through many back-and-forth emails and detailed instructions to help me. The load cell amplifier now works as advertised. I am very content with this purchase and ATO's dedication and patience in helping its customers!
Was this review helpful? (0/0)
how to read peak value with the amplifier?
Steven
2/27/2024 4:41 PM
We are wondering how one reads "peak load value" with just the amplifier readout? We were told it could do this, but there is nothing in the documentation.
Was this review helpful? (0/0)
there is a problem
Alexia
7/17/2024 3:02 AM
When the monitor is powered on, there is a problem with my load cell amplifier, with only monitor 610-3.2 and no button response. How to solve it?
Was this review helpful? (0/1)
Display problem
Aldis
7/24/2024 7:29 PM
Your load cell amplifier with display can show units in Newtons, how is this done? Also, is it possible to display in pounds?
Was this review helpful? (0/0)
Digital Load Cell Amplifier, Output 4-20mA/0-10V/RS485
Moises
8/6/2024 10:05 AM
Through Modbus-rtu only managed to get the current value of the weight.
I'm trying to do the calibration through the modbus-tru but I haven't been able to do it.
I am using a click plc with modbus-rtu communication.
Do you have a more specific manual or tell me if it is possible or not to communicate this indicator with a PLC through Modbus-RTU communication?
I'm trying to do the calibration through the modbus-tru but I haven't been able to do it.
I am using a click plc with modbus-rtu communication.
Do you have a more specific manual or tell me if it is possible or not to communicate this indicator with a PLC through Modbus-RTU communication?
Was this review helpful? (0/0)
I have some questions about the video
Neuville
11/18/2024 12:44 AM
I have purchased 4 ATO-LCTR-OAR load cell amplifiers. The instruction supplied are difficult for me to follow. Several YouTube videos are available but still very unclear. They are slightly helpful but some videos conflict with each other. Could you please provide more clear instructions. Our application is fairly simple. 0-100 lbs. 0-10 volt output. Please respond as soon as possible.
Was this review helpful? (0/0)
STEP drawing
Jepas
6/3/2026 12:41 AM
I am looking for the #D model of a digital load cell amplifier with an output of 4-20mA/0-10V/RS485, and I need the STEP drawing.
Was this review helpful? (0/0)
Signals and calibration
Motsey
10/7/2026 2:24 AM
I'd like to confirm if the ATO-DYN-202 requires a specific transmitter or display instrument's proprietary output signal. Also, does your product support recalibration?
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
Load Cell Junction Box for Scales, 2/3/4/6/8/10 Inlets to 1 Outlet
ATO-LCBOX-10I
$66.67
Multi-channel load cell junction box has 2/3/4/6/8/10 inlets and 1 outlet, aluminum alloy casing, good anti-interference, special for waterproof sealing joint, waterproof and dustproof rubber gasket for cover, easy to assemble and debug. Each channel can be adjusted balance to prevent damage to the sensor caused by inductive lightning and surge signals.
Tension and Compression Load Cell, 100kg/1 ton/2 ton to 20 ton
ATO-LC-S05
$104.29
Tension and compression load cell can bear both tension and pressure, with good output symmetry, high eccentric load resistant, compact structure and complete specifications. Strain gauge load cell can be applied for batching scale, crane scales and other special weighing instruments.
Tension/Compression Load Cell, Low Profile, 500kg/30 ton to 100 ton
ATO-LC-P02
$145.28
Low profile load cell also known as pancake load cell, has flat design, high strength and good symmetry. Tension and compression load cell can be applied for platform scale, truck scale, rail weighbridge and material level measurement and control in warehouse, with good anti-eccentric load performance, low height, all sealed structure and complete specifications.
Strain Gauge Load Cell, S type, 5kg/50kg/1000kg/3 ton to 20 ton
ATO-LC-S01
$88.41
S type load cell can bear both tension and pressure, with good output symmetry, high accuracy, compact structure and complete specifications. Strain gauge load cell can be applied for batching scale, electronic-mechanical scale, crane scales and other force value measurement and control.
Compression Load Cell, 300kg/1000kg/25 ton/50 ton to 100 ton
ATO-LC-P01
$116.78
Compression load cell is special designed for weight measurement, with good anti-eccentric load performance, low height, all sealed, complete specifications, Load cell can be applied for platform scale, truck scale, rail weighbridge and material level measurement and control in warehouse.