$421.89
Sulphur Dioxide (SO2) Monitor, with measure range of 0 to 20 ppm, 0 to 50 ppm, 0 to 100 ppm, outstanding resolution of 0.1 ppm, and response time of less than 10 seconds, this monitor is a dependable tool for a wide range of industrial and environmental applications.
SKU: GD800-SO2
*
Free Shipping
Delivery date: 6-12 days

Our Sulphur Dioxide (SO2) Monitor, with a measurement range of  0 to 20 ppm, 0 to 50 ppm, 0 to 100 ppm, an impressive resolution of 0.1 ppm, and a rapid response time of less than 10 seconds.

Specification

ModelGD800-SO2
Detected gasSO2
Sampling methodDiffusion
Range (optional)
0-20ppm, 0-50ppm, 0-100ppm
Resolution
0.1 ppm
Response time≤10S
PrincipleElectrochemical principle
Alarm modeSound, light, vibration alarm, high and low alarm values can be set by yourself
Alarm typeLow alarm, high alarm, STEL, TWA, low battery
Explosion-proof gradeII 1G Ex da ia IIC T4 Ga
Protection classIP68
Working temperature-20℃~55℃
Working humidity0-95%RH (non-condensing)
Working air pressure86~106kpa
Dimensions90*60*33mm (length*width*thickness)
WeightWeight 125g

Note 1:

  • If you require an SO2 gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

Features

  1. Exceptionally low power consumption ensures an extended standby time of up to 2 years, eliminating the need for battery replacement.
  2. Maintenance-free operation simplifies usage – just power it on, and SO2 monitor runs continuously without requiring calibration, sensor replacements, or battery charging.
  3. Equipped with a high-intensity buzzer alarm, coupled with dual high-brightness red LEDs for both upward and downward alarms, offering sound, light, and vibration triple alarms to effectively alert workers.
  4. Multiple alarm types, including high point, low point, TWA, and STEL, can be customized by users to adjust alarm set points as needed throughout the device's lifecycle.
  5. Featuring an impressive IP68 protection rating, SO2 monitor is resistant to splashes, dust, explosions, shocks, and is equipped with an intrinsically safe circuit design.
  6. Its compact and lightweight design, coupled with a user-friendly two-button interface, ensures easy operation without the need for extensive training.
  7. Offers affordability with a low cost of ownership, making SO2 monitor a budget-friendly solution for your gas detection needs.
  8. Compact and lightweight, it's effortlessly portable, allowing users to carry it with ease.
  9. Crafted from high-strength materials, the device is designed to withstand a variety of harsh environments, ensuring both comfort and durability.
  10. Includes a self-test function, enhancing safety by facilitating automatic self-testing, a valuable feature for peace of mind in critical applications.

Structure

Mini portable oxygen gas detector structureApplications

The SO2 detector finds versatile applications across various industries, including: petrochemical & chemical industry, municipal engineering & utilities, municipal engineering & utilities, electronic, food & pharmaceutical industry, other industries.

SO2 monitor applications

Tips: How does an SO2 monitor work?

  • Electrochemical Sensor: The heart of most SO2 monitors is an electrochemical sensor. This sensor is a small, compact device with three main components: a working electrode, a reference electrode, and an electrolyte.
  • Gas Diffusion: Air containing sulfur dioxide is drawn into the monitor. The gas molecules diffuse through a gas-permeable membrane or filter that allows only SO2 to pass through.
  • Electrochemical Reaction: Inside the sensor, when SO2 molecules come into contact with the working electrode, a chemical reaction occurs. The SO2 gas is oxidized at the working electrode, producing sulfate ions (SO4^2-) in the process. This reaction is specific to SO2 and doesn't respond to other gases.
  • Electrolyte Conductivity: As the oxidation reaction takes place, the concentration of sulfate ions in the electrolyte changes. This alters the electrical conductivity of the electrolyte in a way that is directly proportional to the concentration of SO2 in the sampled air.
  • Measuring Conductivity: The change in conductivity is measured as an electrical current by the monitor's electronics. The current is directly related to the concentration of SO2 in the air.
  • Conversion to ppm: The monitor's internal circuitry converts the measured electrical current into a concentration reading in parts per million (ppm). This ppm reading is then displayed on the monitor's screen.
  • Calibration and Compensation: To ensure accuracy, SO2 monitors are typically calibrated to known standards of SO2 concentration. Some monitors also have mechanisms to compensate for environmental factors like temperature and humidity that can affect sensor performance.
  • Data Output and Alarms: SO2 monitors often have data output options, such as analog or digital signals, for integration with control systems or data logging. They may also have alarms that can be triggered if the SO2 concentration exceeds a predefined threshold.

Basic Settings of Gas Detector

This video we're gonna guide you through some basic operational user functions.

How to Test a Small Handheld Single Gas Detector?

In this video, it is shown how to test a small handheld single gas detector. This is a simple safety device that everyone should have. It is small, easy to carry, lightweight and easy to use.

Product reviews
Exceptional Performance
5
Sofin
Avatar
2/7/2025 7:03 PM
The Sulphur Dioxide (SO2) Monitor has exceeded my expectations in terms of its reliability, accuracy, and user-friendliness. As an environmental scientist, I rely on precise data to assess air quality, and this monitor has proven to be an invaluable tool in my research.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Our Sulphur Dioxide (SO2) Monitor, with a measurement range of  0 to 20 ppm, 0 to 50 ppm, 0 to 100 ppm, an impressive resolution of 0.1 ppm, and a rapid response time of less than 10 seconds.

Specification

ModelGD800-SO2
Detected gasSO2
Sampling methodDiffusion
Range (optional)
0-20ppm, 0-50ppm, 0-100ppm
Resolution
0.1 ppm
Response time≤10S
PrincipleElectrochemical principle
Alarm modeSound, light, vibration alarm, high and low alarm values can be set by yourself
Alarm typeLow alarm, high alarm, STEL, TWA, low battery
Explosion-proof gradeII 1G Ex da ia IIC T4 Ga
Protection classIP68
Working temperature-20℃~55℃
Working humidity0-95%RH (non-condensing)
Working air pressure86~106kpa
Dimensions90*60*33mm (length*width*thickness)
WeightWeight 125g

Note 1:

  • If you require an SO2 gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

Features

  1. Exceptionally low power consumption ensures an extended standby time of up to 2 years, eliminating the need for battery replacement.
  2. Maintenance-free operation simplifies usage – just power it on, and SO2 monitor runs continuously without requiring calibration, sensor replacements, or battery charging.
  3. Equipped with a high-intensity buzzer alarm, coupled with dual high-brightness red LEDs for both upward and downward alarms, offering sound, light, and vibration triple alarms to effectively alert workers.
  4. Multiple alarm types, including high point, low point, TWA, and STEL, can be customized by users to adjust alarm set points as needed throughout the device's lifecycle.
  5. Featuring an impressive IP68 protection rating, SO2 monitor is resistant to splashes, dust, explosions, shocks, and is equipped with an intrinsically safe circuit design.
  6. Its compact and lightweight design, coupled with a user-friendly two-button interface, ensures easy operation without the need for extensive training.
  7. Offers affordability with a low cost of ownership, making SO2 monitor a budget-friendly solution for your gas detection needs.
  8. Compact and lightweight, it's effortlessly portable, allowing users to carry it with ease.
  9. Crafted from high-strength materials, the device is designed to withstand a variety of harsh environments, ensuring both comfort and durability.
  10. Includes a self-test function, enhancing safety by facilitating automatic self-testing, a valuable feature for peace of mind in critical applications.

Structure

Mini portable oxygen gas detector structureApplications

The SO2 detector finds versatile applications across various industries, including: petrochemical & chemical industry, municipal engineering & utilities, municipal engineering & utilities, electronic, food & pharmaceutical industry, other industries.

SO2 monitor applications

Tips: How does an SO2 monitor work?

  • Electrochemical Sensor: The heart of most SO2 monitors is an electrochemical sensor. This sensor is a small, compact device with three main components: a working electrode, a reference electrode, and an electrolyte.
  • Gas Diffusion: Air containing sulfur dioxide is drawn into the monitor. The gas molecules diffuse through a gas-permeable membrane or filter that allows only SO2 to pass through.
  • Electrochemical Reaction: Inside the sensor, when SO2 molecules come into contact with the working electrode, a chemical reaction occurs. The SO2 gas is oxidized at the working electrode, producing sulfate ions (SO4^2-) in the process. This reaction is specific to SO2 and doesn't respond to other gases.
  • Electrolyte Conductivity: As the oxidation reaction takes place, the concentration of sulfate ions in the electrolyte changes. This alters the electrical conductivity of the electrolyte in a way that is directly proportional to the concentration of SO2 in the sampled air.
  • Measuring Conductivity: The change in conductivity is measured as an electrical current by the monitor's electronics. The current is directly related to the concentration of SO2 in the air.
  • Conversion to ppm: The monitor's internal circuitry converts the measured electrical current into a concentration reading in parts per million (ppm). This ppm reading is then displayed on the monitor's screen.
  • Calibration and Compensation: To ensure accuracy, SO2 monitors are typically calibrated to known standards of SO2 concentration. Some monitors also have mechanisms to compensate for environmental factors like temperature and humidity that can affect sensor performance.
  • Data Output and Alarms: SO2 monitors often have data output options, such as analog or digital signals, for integration with control systems or data logging. They may also have alarms that can be triggered if the SO2 concentration exceeds a predefined threshold.
Product reviews
Exceptional Performance
5
Sofin
Avatar
2/7/2025 7:03 PM
The Sulphur Dioxide (SO2) Monitor has exceeded my expectations in terms of its reliability, accuracy, and user-friendliness. As an environmental scientist, I rely on precise data to assess air quality, and this monitor has proven to be an invaluable tool in my research.
Was this review helpful? Yes No (0/0)