Inductive proximity sensor with M5×1 thread and PNP output, available directly from the manufacturer. Its compact M5 design is especially suitable for space-constrained equipment and tight installation environments. Insulation impedance between the charging part and housing is ≥50MΩ (DC 500 megameter), ensuring robust electrical safety.
Functions
- Red LED checks the state of the proximity sensor
- High repeated positioning accuracy
- High switching frequency
- Wide voltage range 12-24V DC
- Antivibration, dust, water and oil prevention
- Reverse power protection, short circuit protection, directly connecting with PLC
- PNP output positive signal for PLC, NPN gives 0V, verify PLC input type
- Can replace small switches and limit switches
Specification
| Model | ATO-PSI-5A1ZP | ||
| Installation type | Shielded | ||
| All the output methods | DC type | NPN | NO |
| NC | |||
| PNP | NO | ||
| NC | |||
| 2 wire | NO | ||
| NC | |||
| Detection range | 1mm±10% | ||
| Setting distance | 0-0.7mm | ||
| Delay distance | ≤10% detection range | ||
| Detection object | Magnetic metal (the detection distance decreases when it is non-magnetic metal) | ||
| Standard detection object | Iron 5*5*1mm | ||
| Response frequency | DC: 2kHz, AC: 50Hz | ||
| Supply voltage | DC type: DC 12-24V (6-36V), impulse (p-p) 10% below; AC type: AC 110-220V (90-250V) 50/60Hz | ||
| Withstand voltage | AC1000V 50/60Hz 1min between charging part and housing | ||
| Voltage influence | Inside ±15% rated supply voltage range, at rated supply voltage value, inside ±10% detection distance | ||
| Consumption current | N/P type: ≤13mA, D type: ≤0.8mA, A type: ≤1.7mA | ||
| Control output | N/P type: ≤300mA, D type: ≤200mA, A type: ≤400mA | ||
| Loop protection | N/P/D type: reversal connection protection, surge absorption, load short-circuit protection; A type: surge absorption | ||
| Ambient temperature & humidity | Operation temperature/storage temperature: -30~65℃ (no freeze, no dew); Operation humidity/storage humidity: 35~95%RH | ||
| Temperature influence | Temperature range -30~65℃, at +23℃, ±15% detection distance; Temperature range -25~60℃, at +23℃, ±10% detection distance | ||
| Insulation impedance | ≥50MΩ (DC500 megameter) between charging part and housing | ||
| Material | Housing: Nickel-plated brass, Detection surface: ABS | ||
| Protection class | IP67 | ||
| Cable length | 1.2m | ||
Dimensional drawing (unit: mm)

Wiring diagram

Tips: What is the difference between NO and NC Inductive Proximity Sensor?
A Normally Open (NO) inductive proximity sensor keeps its output OFF (no signal) when no metal target is detected, and turns ON (delivers a positive voltage for PNP type) as soon as the target enters the sensing range. This makes a NO inductive proximity sensor ideal for simple presence detection, part counting, and positioning tasks where a signal is only required when the object is present.
In contrast, a Normally Closed (NC) sensor maintains a continuous ON signal under normal conditions, and switches OFF (drops to 0V) when the target is detected. NC is preferred for fail-safe control systems, because any broken wire or power loss also cuts the signal, immediately triggering an alarm or machine stop. When choosing between them, select NO for standard on-demand detection and NC for safety-critical circuits that require constant loop monitoring. Always verify your PLC input type (PNP or NPN) and wiring to ensure proper compatibility with your selected output logic.