Features
- Using world top brand sensors, to guarantee the test results reliable and accurate.
- Multiple industrial pump gas sampling, ten grades of pumping flow rate for selection.
- Multi-display mode is switchable.
- Various gas concentration units can be shifted freely.
- Modular internal structure (can be customized for 1-18 gases detection)
- With an indepedent SD memory card, can view and delet the historical detection data.
- High capacity rechargeable lithium polymer battery, long operation time and standby time
- 3.5-inch hd LCD screen and 120 degree wide view, beautiful and useful menu interface
Specification
| Model | GD600-4GAS |
| Sampling Method | Pumping suction, 10 grades adjustable, flow rate range 0-500 mL/min. |
| Detection Principle | Electrochemistry |
| Detecting Gas * | NO2, SO2, CO, O3 |
| Measure Range | NO2: 0 to 10 ppm, SO2: 0 to 10 ppm, CO: 0 to 20 ppm, O3: 0 to 10 ppm |
| Resolution | NO2: 0.001ppm, SO2: 0.001ppm, CO: 0.001ppm, O3: 0.001ppm |
| Accuracy | ≤±2% F.S. |
| Data Storage | 8G SD memory card |
| Alarm | Buzzer, red LED and alarm status on the display, fault alarm, pump abnormal alarm, low battery alarm |
| Display | 3.5 inch hd LCD display with resolution 320*480 |
| Language | Chinese/English |
| Battery | Large capacity rechargeable lithium battery |
| Explosion-proof Grade | II 1G Ex da ia IIC T4 Ga |
| Protection Grade | IP65 |
| Certification | CE, ATEX |
| Operating Temperature | -40℃~70℃ |
| Operating Humidity | 0~95%RH (non-condensing) |
| Dimension | 260*230*120mm |
| Weight | 3700g |
| Standard Accessories | User manual, Micro-USB cable, Water vapour smoke filter, Intake sampling rod, 600mm tube, Carrying case |
| Optional Accessories * | Printer (built-in printer or external bluetooth printer), Pressure sensor, High temperature gun |
Note:
* For the detected gas, it can be customized. This multi-gas analyzer can detect up to 18 gases simultaneously, such as combustible gas, O2, CO2, H2S, NH3, NO, VOC, and so on. If you have any requirements about the detectied gases and measuring range, please feel free to contact us.
* For the optional accessories, please contact us if you need it.
Details

Applications
Portable gas analyzer can be widely used in the university laboratory, research institute, large oil refinery, metallurgical plant, inspectation and quarantine bureau, hospital, mines, tunnel engineeringsite, etc.

Product reviews
Looking for the multi gas analyzer to measure CO2, N2O, NH3 and CH4.
David
7/16/2020 6:50 PM
I'm looking for the multi gas analyzer to measure CO2, N2O, NH3 and CH4 gases. Do you have it?
Was this review helpful? (0/0)
Does ATO provide fixed gas detectors?
Jon
11/2/2021 9:31 PM
Do you provide a fixed gas detector to measure hydrocarbon gases (petroleum products)?
Was this review helpful? (0/0)
How long does it take to get to your O3 gas detector to be in full charge?
Kaleb
12/14/2021 1:21 AM
How long does it take to get to your O3 gas detector to be in full charge?
Was this review helpful? (0/0)
What temperature can the detectors operate up to?
abner
7/19/2023 3:39 AM
Sorry for the delay in getting back to you. The H2O comment was in the context of water vapor, but it is not critical.
N2 is also not critical, we would however be interested in SO2 in the range of (0-200ppm). Let me know if a CO2: 0-100%VOL, CO: 0-200ppm, NO2: 0-200ppm, SO2: 0-200ppm setup would be possible.
The detector would be used indoors and would be connected to inlet and outlet piping. The humidity will be low and temperatures and pressures are close to ambient.
Flow rates through the pipeline will be in the range of 0 to 300L/min, however, we’re imagining the detectors would sit on a bypass line where the flow rate could be significantly reduced.
We would be interested to know what temperature the detectors can operate up to.
N2 is also not critical, we would however be interested in SO2 in the range of (0-200ppm). Let me know if a CO2: 0-100%VOL, CO: 0-200ppm, NO2: 0-200ppm, SO2: 0-200ppm setup would be possible.
The detector would be used indoors and would be connected to inlet and outlet piping. The humidity will be low and temperatures and pressures are close to ambient.
Flow rates through the pipeline will be in the range of 0 to 300L/min, however, we’re imagining the detectors would sit on a bypass line where the flow rate could be significantly reduced.
We would be interested to know what temperature the detectors can operate up to.
Was this review helpful? (0/0)
Only registered users can write reviews