Programmable Logic Controller, 16/24/32/40/60 I/O, Relay/Transistor Output

$172.31
Low price PLC Programmable Logic Controller for sale, high-speed 32-bit CPU, 16 / 20 / 24/ 32 / 40 / 60 I/O points, 16k steps program capacity and 10k data register built-in 1 RS-232 and 2 RS-485 ports, 100 ~ 240V AC power supply. PLC controller has digital input & relay or transistor output, providing 8 - 36 input points and 8 - 24 output points, high capability and fast logic operation, a perfect solution for controlling your automation systems.
SKU: ATO-PLC-ES2
*
Free Shipping
Delivery date: 6-12 days

Standard PLCs (Programmable Logic Controller) with integrated communication and highly efficient processing ability is great for your control systems such as HVAC, printing machine, packaging machine, molding injection machine, inspection system.

Features

  • 32-bit CPU for high-speed processing
  • Standard PLC-ES2 Series: 16 / 20 / 24 / 32 / 40 / 60 I/O points for a variety of applications
  • Built-in 1 RS-232 and 2 RS-485 ports
  • Program capacity: 16 k steps
  • Data register: 10 k words
  • Max. execution speed of basic instructions: 0.35 μs
  • RTC function and file register (5 k words)
  • Highly efficient processing ability: 1 k steps of programs can be completed within 1ms
  • Max. 100 kHz pulse control; specific motion control instructions (mark/masking and instant frequency changing) available for multi-axis applications
  • Up to 4 levels of password protection secures your source programs and intellectual property

Specification

ModelATO-DVP-ES2
Builit-in I/O16 / 20 / 24 / 32 / 40 / 60 I/O points
Power Supply100 ~ 240V AC (-15% ~ +10%), 50/60Hz ±5%
ConnectorEuropean standard removable terminal block (Pin pitch: 5mm)
OperationATO-DVP-ES2 PLC starts to run when the power rises to 95~100V AC and stops when the power drops to 70V AC.
If the power is suddenly cut off, the PLC will continue running for 10ms.
Power Supply Fuse2A / 250V AC
Power Consumption30VA
DC 24V Current Output *1500mA
Power Supply ProtectionDC 24V output short circuit protection
Voltage Withstand1500VAC (Primary-secondary), 1500VAC (Primary-PE), 500VAC (Secondary-PE)
Insulation Resistance>5MΩ at 500VDC (between all I/O points and ground)
Noise ImmunityESD (IEC 61131-2, IEC 61000-4-2): 8kV Air Discharge
EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2kV, Digital I/O: 1kV, Analog & Communication I/O: 1kV
RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m
GroundingThe diameter of grounding wire shall not be less than that of L, N terminal of the power supply.
(When many PLCs are in use at the same time, please make sure every PLC is properly grounded.)
EnvironmentOperation: 0°C~55°C (temperature), 5~95% (humidity), pollution degree 2
Storage: -25°C~70°C (temperature), 5~95% (humidity)
ApprovalsUL508, European community EMC Directive 89/336/EEC and Low Voltage Directive 73/23/EEC
Vibration/Shock ImmunityInternational standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/ IEC61131-2 & IEC 68-2-27 (TEST Ea)
WeightSee below "Selection Table"
Note:
*1. It is suggested that the power output should not be supplied to HMIs.

Selection Table

ModelBuilit-in I/ONumber of InputsNumber of OutputsOutput Type
Weight
DVP16ES200R1688Relay377g
DVP16ES200T1688Transistor351g
DVP24ES200R24168Relay414g
DVP24ES200T24168Transistor387g
DVP32ES200R321616Relay489g
DVP32ES200T321616Transistor432g
DVP40ES200R402416Relay554g
DVP40ES200T402416Transistor432g
DVP58ES200R582436Relay554g
DVP58ES200T582436Transistor498g
DVP60ES200R603624Relay705g
DVP60ES200T603624Transistor622g

PLC I/O Point Specification

Input Points
Input Point No.X0 ~ X3 #1X4 ~ X7X10 ~ X17, X20 ~  #2
Input Point TypeDigital input
Input FormDC (SINK or SOURCE)
Input Currrent24VDC, 5mA
Input Impedance4.7KΩ
Max. Input Frequency100kHz10kHz60Hz
Action LevelOff → On>15VDC
On → Off< 5VDC
Response TimeOff → On< 2.5μs< 20μs< 10ms
On → Off< 5μs< 50μs< 15ms
Filter TimeX0 ~ X7Adjustable within 0 ~ 20ms in D1020 (Default: 10ms)
Output Points
Output Point TypeRelay - RTransistor - T
Output Point No.AllY0, Y2Y1, Y3Y4 ~ Y17, Y20 ~ #2
Voltage Spec.< 250VAC, 30VDC5 ~ 30VDC #3
Max. Output Frequency1Hz100kHz10kHz1kHz
Maximum LoadResistive2A/point (5A/COM)0.5A/1 point (4A/COM) #5
Inductive#415W (30VDC)
Lamp20W DC/100W AC2.5W (30VDC)
Response TimeOff → OnApprox .10ms< 2μs< 20μs< 100μs
On → Off< 3μs< 30μs< 100μs
Note:
#1. The counting frequency of X1 and X3 on the DVP-ES200 series PLCs has increased from 10kHz to 100kHz after 2013.
#2. Please refer to “I/O Terminal Layouts” for the max. X/Y No. on each model.
#3. UP, ZP must work with external auxiliary power supply 24V DC (-15% ~ +20%), rated consumption approx. 1mA/point.
#4. Life curves
PLC Controller Life Curve
#5. ZP for NPN COM, UP for PNP COM.

Product Details

PLC Controller Introduction

PLC Dimensions (Unit: mm)

ES2 Series PLC Demensions

ModelDVP16ES200R/TDVP24ES200R/TDVP32ES200R/TDVP40ES200R/TDVP58ES200R/TDVP60ES200R/T
L105125145165225225
L197117137157217217

How to control a stepper motor using a PLC and HMI?

This video shows you how to configure a PLC, HMI, motor driver, and proximity sensor to perform Origin Return (OPR) control of a stepper motor.

Four Ways to Control VFD with PLC

This video introduces the main wiring methods between PLC and VFD, including digital control, analog control, serial communication and Ethernet connection. The choice of connection method depends on the specific application requirements, system complexity, cost considerations and the need for control accuracy and flexibility.

PLC and HMI Analog Output (0-10V) Programming

In this tutorial, we will walk you through the structured system setup between the HMI, PLC, and VFD, as well as the programming steps required for seamless operation.

Product reviews
Repeaters of programmable logic controller
5
Susanin
Avatar
9/16/2021 12:00 AM
I like this programmable logic controller very much. It has 1RS-232 and 2RS-485, which can perform arithmetic operations quickly. If necessary, I will continue to buy this programmable logic controller.
Was this review helpful? Yes No (0/0)
A reliable, easy-to-use PLC that performs consistently in daily workflows
5
Ronaldo
Avatar
11/30/2025 8:58 PM
This PLC is easy to set up, runs instructions fast, offers reliable and sufficient I/O, and performs solidly in real applications.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Standard PLCs (Programmable Logic Controller) with integrated communication and highly efficient processing ability is great for your control systems such as HVAC, printing machine, packaging machine, molding injection machine, inspection system.

Features

  • 32-bit CPU for high-speed processing
  • Standard PLC-ES2 Series: 16 / 20 / 24 / 32 / 40 / 60 I/O points for a variety of applications
  • Built-in 1 RS-232 and 2 RS-485 ports
  • Program capacity: 16 k steps
  • Data register: 10 k words
  • Max. execution speed of basic instructions: 0.35 μs
  • RTC function and file register (5 k words)
  • Highly efficient processing ability: 1 k steps of programs can be completed within 1ms
  • Max. 100 kHz pulse control; specific motion control instructions (mark/masking and instant frequency changing) available for multi-axis applications
  • Up to 4 levels of password protection secures your source programs and intellectual property

Specification

ModelATO-DVP-ES2
Builit-in I/O16 / 20 / 24 / 32 / 40 / 60 I/O points
Power Supply100 ~ 240V AC (-15% ~ +10%), 50/60Hz ±5%
ConnectorEuropean standard removable terminal block (Pin pitch: 5mm)
OperationATO-DVP-ES2 PLC starts to run when the power rises to 95~100V AC and stops when the power drops to 70V AC.
If the power is suddenly cut off, the PLC will continue running for 10ms.
Power Supply Fuse2A / 250V AC
Power Consumption30VA
DC 24V Current Output *1500mA
Power Supply ProtectionDC 24V output short circuit protection
Voltage Withstand1500VAC (Primary-secondary), 1500VAC (Primary-PE), 500VAC (Secondary-PE)
Insulation Resistance>5MΩ at 500VDC (between all I/O points and ground)
Noise ImmunityESD (IEC 61131-2, IEC 61000-4-2): 8kV Air Discharge
EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2kV, Digital I/O: 1kV, Analog & Communication I/O: 1kV
RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m
GroundingThe diameter of grounding wire shall not be less than that of L, N terminal of the power supply.
(When many PLCs are in use at the same time, please make sure every PLC is properly grounded.)
EnvironmentOperation: 0°C~55°C (temperature), 5~95% (humidity), pollution degree 2
Storage: -25°C~70°C (temperature), 5~95% (humidity)
ApprovalsUL508, European community EMC Directive 89/336/EEC and Low Voltage Directive 73/23/EEC
Vibration/Shock ImmunityInternational standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/ IEC61131-2 & IEC 68-2-27 (TEST Ea)
WeightSee below "Selection Table"
Note:
*1. It is suggested that the power output should not be supplied to HMIs.

Selection Table

ModelBuilit-in I/ONumber of InputsNumber of OutputsOutput Type
Weight
DVP16ES200R1688Relay377g
DVP16ES200T1688Transistor351g
DVP24ES200R24168Relay414g
DVP24ES200T24168Transistor387g
DVP32ES200R321616Relay489g
DVP32ES200T321616Transistor432g
DVP40ES200R402416Relay554g
DVP40ES200T402416Transistor432g
DVP58ES200R582436Relay554g
DVP58ES200T582436Transistor498g
DVP60ES200R603624Relay705g
DVP60ES200T603624Transistor622g

PLC I/O Point Specification

Input Points
Input Point No.X0 ~ X3 #1X4 ~ X7X10 ~ X17, X20 ~  #2
Input Point TypeDigital input
Input FormDC (SINK or SOURCE)
Input Currrent24VDC, 5mA
Input Impedance4.7KΩ
Max. Input Frequency100kHz10kHz60Hz
Action LevelOff → On>15VDC
On → Off< 5VDC
Response TimeOff → On< 2.5μs< 20μs< 10ms
On → Off< 5μs< 50μs< 15ms
Filter TimeX0 ~ X7Adjustable within 0 ~ 20ms in D1020 (Default: 10ms)
Output Points
Output Point TypeRelay - RTransistor - T
Output Point No.AllY0, Y2Y1, Y3Y4 ~ Y17, Y20 ~ #2
Voltage Spec.< 250VAC, 30VDC5 ~ 30VDC #3
Max. Output Frequency1Hz100kHz10kHz1kHz
Maximum LoadResistive2A/point (5A/COM)0.5A/1 point (4A/COM) #5
Inductive#415W (30VDC)
Lamp20W DC/100W AC2.5W (30VDC)
Response TimeOff → OnApprox .10ms< 2μs< 20μs< 100μs
On → Off< 3μs< 30μs< 100μs
Note:
#1. The counting frequency of X1 and X3 on the DVP-ES200 series PLCs has increased from 10kHz to 100kHz after 2013.
#2. Please refer to “I/O Terminal Layouts” for the max. X/Y No. on each model.
#3. UP, ZP must work with external auxiliary power supply 24V DC (-15% ~ +20%), rated consumption approx. 1mA/point.
#4. Life curves
PLC Controller Life Curve
#5. ZP for NPN COM, UP for PNP COM.

Product Details

PLC Controller Introduction

PLC Dimensions (Unit: mm)

ES2 Series PLC Demensions

ModelDVP16ES200R/TDVP24ES200R/TDVP32ES200R/TDVP40ES200R/TDVP58ES200R/TDVP60ES200R/T
L105125145165225225
L197117137157217217
Product reviews
Repeaters of programmable logic controller
5
Susanin
Avatar
9/16/2021 12:00 AM
I like this programmable logic controller very much. It has 1RS-232 and 2RS-485, which can perform arithmetic operations quickly. If necessary, I will continue to buy this programmable logic controller.
Was this review helpful? Yes No (0/0)
A reliable, easy-to-use PLC that performs consistently in daily workflows
5
Ronaldo
Avatar
11/30/2025 8:58 PM
This PLC is easy to set up, runs instructions fast, offers reliable and sufficient I/O, and performs solidly in real applications.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews