Digital pH/ORP Meter for Water Testing

$298.28
Digital pH/ORP meter is a high quality online pH/ORP controller. The pH/ORP meter can be used in various severe environment. It is used to test and monitor the pH (0~14) / ORP (-1000~1000mV) / temperature (0~100℃/32~212℉) of sewage, corrosive solution, liquid medicine, beer, drinking water, food, etc. The pH detector transmits standard output signal 4-20mA to digital panel meter/VFD/PLC/recorder, or RS485 signal to a computer for remote monitoring and recording.
SKU: ATO-PHM-PH160
*
*
Free Shipping
Delivery date: 6-12 days

Digital pH/ORP meter is an industrial pH/ORP meter for water/food pH value or ORP value testing and monitoring.

Application:
Digital pH/ORP meter is widely used in the continuous testing and monitoring of pH, ORP and temperature in thermal power, chemical fertilizer, metallurgy, environmental protection, pharmaceutical, biochemical, food, drinking water, etc.

Function:

  • 2.4 inch LCD display
  • Good anti-interference performance
  • Manual/automatic temperature compensation
  • User settings: Language, buzzer, LCD backlight, password, pH/ORP electrode, manual/automatic temperature compensation, pH/ORP calibration, pH/ORP/temperature modification, pH/ORP high/low alarm, output signal 4-20mA and RS485, etc.
  • Internal industrial watchdog insures pH meter doesn't crash.

Specification:

ModelATO-PHCR-PH160
Weight1kg
Dimension96*96*100mm (H*W*D) with hole size 92*92mm
Measuring rangepH: 0~14pH, ORP: -1000~1000mV (-2000~2000mV can be customizable)
Accuracy±0.02pH, ±1mV
Resolution±0.01pH, ±1mV
Stability≤0.02pH/24h, ≤3mV/24h
Input impedance≥10^12Ω
Temperature range0~100℃ (NTC 10K, accuracy: ±0.5℃)
Temperature compensation0~100℃ manual/automatic
Output signalIsolated 4-20mA signal (error: ±0.2%, under maximum loop resistance 750Ω)
Communication functionRS485 with standard MODBUS-RTU (Now RS485 software is free.)
Power supplyAC 220V±10%, 50Hz/60Hz
DC 24V
Alarm relay2 alarm relays: AC 250V/3A
Function: high alarm, low alarm

The pH meter and pH/ORP electrode selection:

pH meterpH/ORP electrodeIndustryTemperature rangeAdvantage
ATO-PHCR-PH160Combination pH electrodeSewage disposal0-60℃ (32-140℉)Combination electrode has automatic temperature compensation function, suitable for occasions with large temperature fluctuations.
Pure water pH electrodeDrinking water0-60℃ (32-140℉)The pH calomel electrode can be used in strong acid or alkali.
PTFE pH electrodeChemical0-60℃ (32-140℉)The electrode shell is made of PTFE, suitable for corrosive solution (strong acid or alkali), has longer life in harsh environments.
pH glass electrodeSewage disposal / food0-95℃ (32-203℉)Direct lead, double-layer glasses.
Desulfurization pH electrodeDesulfurization0-60℃ (32-140℉)Flat electrode, strong anti-pollution ability and longer life
High temperature/sterilization pH electrodeFood-5℃-130℃ (23-266℉)The electrode can withstand high temperature of 0-130℃, suitable for occasions of high temperature sterilization in pharmaceutical factories, breweries, etc.
High pressure/accuracy pH electrodeLaboratory-5℃-130℃ (23-266℉)Its linearity and accuracy are higher than all above electrodes.

The pH/ORP meter diagram of ports definition:
Digital pH/ORP meter wiring diagram

  • INPUT: Measuring terminal of the electrode
  • REF: Reference terminal of the electrode
  • NC: Undefined
  • TEMP2: Temperature compensation terminal 2
  • TEMP1: Temperature compensation terminal 1
  • RS485 (A+): RS485 communication interface A+
  • RS485 (B-): RS485 communication interface B-
  • 4-20mA (+): 4-20mA output terminal +
  • 4-20mA (-): 4-20mA output terminal -
  • AC 220V (L) or DC 24V (-): AC 220V liver wire or DC 24V negative
  • AC 220V (N) or DC 24V (+): AC 220V liver wire or DC 24V positive
  • LO: Normally-open relay for low alarm
  • HI: Normally-closed relay for high alarm

Communication:
RS485 communication data and register address as follows:

AddressData typeFunction codeExplanationAccess right
0x0000unsigned short0x03pH value (default in two decimals)Read only
0x0001unsigned short0x03Temperature value (default in one decimals)Read only
0x0002short0x03ORP value (signed integer)Read only

Tips: Why should the pH meter be recalibrated?
After the calibration is completed, the frequently used pH meter does not need to be calibrated again within 48 hours. In case of any of the following situations, the meter needs to be recalibrated:

  1. There's a huge difference between solution temperature and calibration temperature.
  2. The electrode has been exposed in the air for too long, such as more than half an hour.
  3. Position or slope adjuster is moved by mistake.
  4. Peracid solution (pH<2) or overbasic solution (pH>12) is measured.
  5. The electrode is replaced.
  6. pH value of the measured solution is not in the middle of the calibrated value for two points while it's far from 7pH.
Product reviews
This digital pH/ORP meter is very clear
5
Keria
Avatar
12/6/2021 8:13 PM
I received this digital pH/ORP meter, and I have used it in water quality tests in different places. Its screen is very large, and I can see it clearly.
Was this review helpful? Yes No (0/0)
Good product!
5
Zack
Avatar
4/11/2022 2:01 AM
I don't have to worry about my pH meter running dry. Product works as advertised. Vendor was extremely prompt shipping it out. I love ATO. Good product this should last a long time, it only takes 1 or 2 drops in the PH meter to keep the probe good and moist and working accurately.
Was this review helpful? Yes No (0/0)
High accuracy digital pH meter!
5
Nguyen
Avatar
5/25/2022 3:11 AM
With this digital pH/ORP meter, I have found out, you get what you pay for! This one has both, and I check it’s accuracy almost every time I use it, with the “pH test indicator”, I pictured. It has been 99% accurate, with the drops, that is why I gave it 5 Stars for accuracy.
Was this review helpful? Yes No (0/0)
Want to buy a pH probe.
5
Duncan
Avatar
7/27/2022 3:13 AM
We are looking for a pH probe that will be in contact with HF and HCl. We would like to know if your PTFE probes can be used for these application. If it can be used could you provide us a quote for this probe?
Was this review helpful? Yes No (0/0)
ATO Responded
We also need to know:
1. What is the temperature on site?
2. What is the approx length of the rod used for temperature measurement of the temperature sensor require?
Nice pH meter!
5
Theobald
Avatar
3/27/2023 9:12 PM
I am impressed with the Digital pH/ORP Meter for Water Testing. It's easy to use and provides accurate readings of pH and ORP in water. I use it for my hydroponics setup and it has helped me maintain the optimal pH level for my plants. The compact size of the meter makes it easy to carry around.
Was this review helpful? Yes No (0/0)
pH probe calibration
5
Hanavi
Avatar
3/20/2025 8:31 PM
I tried to calibrate the ATO-PHM-PH160 with a pH probe and manual temperature compensation but it didn't work. What should I do?
Was this review helpful? Yes No (0/0)
ATO Responded
You need to adjust the manual temperature compensation and set the temperature to 44 degrees. The specific steps are as follows: In Signal Settings - Temperature Compensation Switch - Manual Temperature Compensation - Set the temperature value to 44 degrees.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Digital pH/ORP meter is an industrial pH/ORP meter for water/food pH value or ORP value testing and monitoring.

Application:
Digital pH/ORP meter is widely used in the continuous testing and monitoring of pH, ORP and temperature in thermal power, chemical fertilizer, metallurgy, environmental protection, pharmaceutical, biochemical, food, drinking water, etc.

Function:

  • 2.4 inch LCD display
  • Good anti-interference performance
  • Manual/automatic temperature compensation
  • User settings: Language, buzzer, LCD backlight, password, pH/ORP electrode, manual/automatic temperature compensation, pH/ORP calibration, pH/ORP/temperature modification, pH/ORP high/low alarm, output signal 4-20mA and RS485, etc.
  • Internal industrial watchdog insures pH meter doesn't crash.

Specification:

ModelATO-PHCR-PH160
Weight1kg
Dimension96*96*100mm (H*W*D) with hole size 92*92mm
Measuring rangepH: 0~14pH, ORP: -1000~1000mV (-2000~2000mV can be customizable)
Accuracy±0.02pH, ±1mV
Resolution±0.01pH, ±1mV
Stability≤0.02pH/24h, ≤3mV/24h
Input impedance≥10^12Ω
Temperature range0~100℃ (NTC 10K, accuracy: ±0.5℃)
Temperature compensation0~100℃ manual/automatic
Output signalIsolated 4-20mA signal (error: ±0.2%, under maximum loop resistance 750Ω)
Communication functionRS485 with standard MODBUS-RTU (Now RS485 software is free.)
Power supplyAC 220V±10%, 50Hz/60Hz
DC 24V
Alarm relay2 alarm relays: AC 250V/3A
Function: high alarm, low alarm

The pH meter and pH/ORP electrode selection:

pH meterpH/ORP electrodeIndustryTemperature rangeAdvantage
ATO-PHCR-PH160Combination pH electrodeSewage disposal0-60℃ (32-140℉)Combination electrode has automatic temperature compensation function, suitable for occasions with large temperature fluctuations.
Pure water pH electrodeDrinking water0-60℃ (32-140℉)The pH calomel electrode can be used in strong acid or alkali.
PTFE pH electrodeChemical0-60℃ (32-140℉)The electrode shell is made of PTFE, suitable for corrosive solution (strong acid or alkali), has longer life in harsh environments.
pH glass electrodeSewage disposal / food0-95℃ (32-203℉)Direct lead, double-layer glasses.
Desulfurization pH electrodeDesulfurization0-60℃ (32-140℉)Flat electrode, strong anti-pollution ability and longer life
High temperature/sterilization pH electrodeFood-5℃-130℃ (23-266℉)The electrode can withstand high temperature of 0-130℃, suitable for occasions of high temperature sterilization in pharmaceutical factories, breweries, etc.
High pressure/accuracy pH electrodeLaboratory-5℃-130℃ (23-266℉)Its linearity and accuracy are higher than all above electrodes.

The pH/ORP meter diagram of ports definition:
Digital pH/ORP meter wiring diagram

  • INPUT: Measuring terminal of the electrode
  • REF: Reference terminal of the electrode
  • NC: Undefined
  • TEMP2: Temperature compensation terminal 2
  • TEMP1: Temperature compensation terminal 1
  • RS485 (A+): RS485 communication interface A+
  • RS485 (B-): RS485 communication interface B-
  • 4-20mA (+): 4-20mA output terminal +
  • 4-20mA (-): 4-20mA output terminal -
  • AC 220V (L) or DC 24V (-): AC 220V liver wire or DC 24V negative
  • AC 220V (N) or DC 24V (+): AC 220V liver wire or DC 24V positive
  • LO: Normally-open relay for low alarm
  • HI: Normally-closed relay for high alarm

Communication:
RS485 communication data and register address as follows:

AddressData typeFunction codeExplanationAccess right
0x0000unsigned short0x03pH value (default in two decimals)Read only
0x0001unsigned short0x03Temperature value (default in one decimals)Read only
0x0002short0x03ORP value (signed integer)Read only

Tips: Why should the pH meter be recalibrated?
After the calibration is completed, the frequently used pH meter does not need to be calibrated again within 48 hours. In case of any of the following situations, the meter needs to be recalibrated:

  1. There's a huge difference between solution temperature and calibration temperature.
  2. The electrode has been exposed in the air for too long, such as more than half an hour.
  3. Position or slope adjuster is moved by mistake.
  4. Peracid solution (pH<2) or overbasic solution (pH>12) is measured.
  5. The electrode is replaced.
  6. pH value of the measured solution is not in the middle of the calibrated value for two points while it's far from 7pH.
Product reviews
This digital pH/ORP meter is very clear
5
Keria
Avatar
12/6/2021 8:13 PM
I received this digital pH/ORP meter, and I have used it in water quality tests in different places. Its screen is very large, and I can see it clearly.
Was this review helpful? Yes No (0/0)
Good product!
5
Zack
Avatar
4/11/2022 2:01 AM
I don't have to worry about my pH meter running dry. Product works as advertised. Vendor was extremely prompt shipping it out. I love ATO. Good product this should last a long time, it only takes 1 or 2 drops in the PH meter to keep the probe good and moist and working accurately.
Was this review helpful? Yes No (0/0)
High accuracy digital pH meter!
5
Nguyen
Avatar
5/25/2022 3:11 AM
With this digital pH/ORP meter, I have found out, you get what you pay for! This one has both, and I check it’s accuracy almost every time I use it, with the “pH test indicator”, I pictured. It has been 99% accurate, with the drops, that is why I gave it 5 Stars for accuracy.
Was this review helpful? Yes No (0/0)
Want to buy a pH probe.
5
Duncan
Avatar
7/27/2022 3:13 AM
We are looking for a pH probe that will be in contact with HF and HCl. We would like to know if your PTFE probes can be used for these application. If it can be used could you provide us a quote for this probe?
Was this review helpful? Yes No (0/0)
ATO Responded
We also need to know:
1. What is the temperature on site?
2. What is the approx length of the rod used for temperature measurement of the temperature sensor require?
Nice pH meter!
5
Theobald
Avatar
3/27/2023 9:12 PM
I am impressed with the Digital pH/ORP Meter for Water Testing. It's easy to use and provides accurate readings of pH and ORP in water. I use it for my hydroponics setup and it has helped me maintain the optimal pH level for my plants. The compact size of the meter makes it easy to carry around.
Was this review helpful? Yes No (0/0)
pH probe calibration
5
Hanavi
Avatar
3/20/2025 8:31 PM
I tried to calibrate the ATO-PHM-PH160 with a pH probe and manual temperature compensation but it didn't work. What should I do?
Was this review helpful? Yes No (0/0)
ATO Responded
You need to adjust the manual temperature compensation and set the temperature to 44 degrees. The specific steps are as follows: In Signal Settings - Temperature Compensation Switch - Manual Temperature Compensation - Set the temperature value to 44 degrees.
Only registered users can write reviews
Customers who bought this item also bought

Combination pH Electrode for Wastewater Treatment

ATO-PHELE-5011
$208.31
This pH electrode product is a bright eye for detecting water quality on Earth. It is independently developed and has a rapid and sensitive response. Online pH meters have advantages such as anti-interference, high accuracy, and good stability.

PTFE pH Electrode for Strong Acid and Alkali

ATO-PHELE-5013A
$179.92
PTFE pH electrode for strong acid and alkali, PTFE shell, good corrosion resistance, 0-60℃ (32-140℉) temperature range, direct lead, 6 months service life.