Digital pH Meter, Online Test pH/ORP of Water/Food

$547.89
Digital pH/ORP meter can be used with various pH electrodes or ORP electrodes to realize online testing and monitoring of pH (-2~+16) / ORP (-1999~+1999mV) / temperature (-10~+130℃/14~266℉) of sewage, corrosive solution, liquid medicine, beer, drinking water, food, etc. Online pH meter can be connected to digital panel meter/VFD/PLC/recorder (4-20mA output), or connected to computer for remote monitoring and recording (RS485 communication). Digital pH detector can also be connected with alarm relays and solenoid valves to form a simple pH process control system.
SKU: ATO-PHM-PH8
*
Free Shipping
Delivery date: 6-12 days

Digital pH meter is an intelligent industrial online pH controller for testing/monitoring/recording water or food pH value, ORP value and temperature value.

Application:
Digital pH/ORP meter is widely used in the continuous testing and monitoring of pH, ORP and temperature in thermal power, chemical fertilizer, metallurgy, environmental protection, pharmaceutical, biochemical, food, drinking water, etc.

Function:

  • 4.3 inch LCD display
  • Good anti-interference performance
  • Manual/automatic temperature compensation
  • User settings: Buzzer, LCD backlight, password, pH/ORP electrode, manual/automatic temperature compensation, pH/ORP calibration, pH/ORP modification, pH/ORP high/low alarm, output signal 4-20mA and RS485, etc.
  • Data record function
  • Automatic cleaning function

Specification:

ModelATO-PHCR-PH8.5
Weight1kg
Dimension144*144*115mm (H*W*D) with hole size 138*138mm
Display4.3 inch LCD color screen
Measuring rangepH/Antimony: -2.00 ~ +16.00pH
ORP: -2000 ~ +2000mV
Temperature: -10.0 ~ +130.0℃
AccuracypH:±0.02pH
Antimony: ±0.2pH
ORP: ±2mV
Temperature:
NTC10K: ±0.3℃ (-10~+60℃), ±2.0℃ (60~130℃)
PT1000/PT100: ±0.3℃
Input impedance≥1012Ω
ResolutionpH/Antimony: 0.01pH
ORP: 1mV
Temperature range0~100℃ (NTC 10K, accuracy: ±0.5℃)
Repeatability0.02pH
Temperature compensationCompensation mode: Manual/Automatic
Compensation curve: Linear, Acid, Base, Pure
Record100 sets, recording interval can be set through configuration, the recording method is FIFO.
Output signal *Isolated 4-20mA signal (error: ±0.2%, under maximum loop resistance 750Ω), default 1 * 4-20mA output, optional 2 * 4-20mA outputs
Communication functionRS485 with standard MODBUS-RTU (Now RS485 software is free.)
Power supplyAC: 85~265V, 50Hz/60Hz
DC: 21.6~26.4V
Alarm relay delay0~9999 seconds, adjustable
Protection classIP66
Operating temperatureTemperature: 0~60℃
Relative Humidity: 10~85%RH (no condensing)
Storage conditionTemperature: -15~+65℃
Relative Humidity: 5~95%RH (no condensing)
Automatic cleaning *Manually clean, set cleaning interval

The pH meter and pH/ORP electrode selection:

pH meterpH/ORP electrodeIndustryTemperature rangeAdvantage
ATO-PHCR-PH8.0Combination pH electrodeSewage disposal0-60℃ (32-140℉)Combination electrode has automatic temperature compensation function, suitable for occasions with large temperature fluctuations.
Pure water pH electrodeDrinking water0-60℃ (32-140℉)The pH calomel electrode can be used in strong acid or alkali.
PTFE pH electrodeChemical0-60℃ (32-140℉)The electrode shell is made of PTFE, suitable for corrosive solution (strong acid or alkali), has longer life in harsh environments.
pH glass electrodeSewage disposal / food0-95℃ (32-203℉)Direct lead, double-layer glasses.
Desulfurization pH electrodeDesulfurization0-60℃ (32-140℉)Flat electrode, strong anti-pollution ability and longer life
High temperature/sterilization pH electrodeFood0-130℃ (32-266℉)The electrode can withstand high temperature of 0-130℃, suitable for occasions of high temperature sterilization in pharmaceutical factories, breweries, etc.
High pressure/accuracy pH electrodeLaboratory0-80℃ (32-176℉)Its linearity and accuracy are higher than all above electrodes.

Wiring diagram:
Digital online water/food pH/ORP meter wiring diagram
Definition of the ports:

  1. INPUT: Measuring terminal of the pH/ORP/Antimony electrode
  2. NC: Undefined
  3. REF: Reference terminal of the pH/ORP/Antimony electrode
  4. NC: Undefined
  5. TEMPA: Temperature compensation terminal A
  6. TEMPB: Temperature compensation terminal B
  7. TEMPC: Temperature compensation terminal C
  8. RS485 (A+): RS485 communication interface A+
  9. RS485 (B-): RS485 communication interface B-
  10. 0/4-20mA (A+): A current output terminal +
  11. 0/4-20mA (A/B-): A/B current output terminal -
  12. 0/4-20mA (B+): B current output terminal +
  13. WASH: Cleaning device relay
  14. WASH: Cleaning device relay
  15. REL B: Alarm relay B
  16. REL B: Alarm relay B
  17. REL A: Alarm relay A
  18. REL A: Alarm relay A
  19. POWER N: AC 220V/110V neutral wire
  20. POWER L: AC 220V/110V live wire

Communication:
RS485 communication data and register address as follows:

AddressAccess authorityData typeData typeFunction codeExplanation
0x0001Read onlyFloat40x03pH/ORP/Antimony electrode measurement value
0x0003Read onlyFloat40x03Temperature measurement value

Tips: How to control the pH value to be 6-9 with a pH meter?
The pH electrode with submersible installation is submerged in the alkali pool to test the pH value. The lower limit alarm relay of the pH meter is connected to a solenoid valve (normally closed solenoid valve).
First, set the lower alarm value to be 6 for closed and 7 for open, when the pH value is below 6, the alarm relay is closed and the dosing pump works to add lye to the pool. When pH value in the pool reaches 7, the alarm relay is closed, and the dosing pump stops to add lye.
Second, set the upper alarm value to be 9 for closed and 8 for open, when the pH value is above 9, the alarm relay is closed and the dosing pump works to add acid liquor to the pool. When pH value in the pool reaches 8, the alarm relay is close and the dosing pump stops to add acid liquor.
Through the alarm return difference, pH value will be controlled between 6 and 9.

Product reviews
The measured data of pH meter is very close to the theoretical value.
5
Kraus
Avatar
10/20/2018 12:51 AM
Digital pH meter is very practical and convenient to carry to other place. The pH meter has high accuracy. The measured data is very close to the theoretical value.
Was this review helpful? Yes No (0/0)
Online pH meter
5
Terrence
Avatar
3/30/2021 2:21 AM
Dear Sir,
Please recommend an online pH meter, with accessory/electrode for continuous testing tape water.  Please quote CIP Hong Kong.  thanks Terrence.
Was this review helpful? Yes No (0/0)
ATO Responded
We recommend this digital pH meter with SKU ATO-PHCON-PH160, and its corresponding product link https://www.ato.com/ph-electrode-for-pure-water. You can click on the product link to see the details.
Can this pH meter be use for PH and ORP?
5
landon
Avatar
7/31/2023 12:01 AM
When I check from the website https://www.ato.com/digital-ph-meter, Digital pH/ORP meter can be used with various pH electrodes or ORP electrodes to realize online testing and monitoring of pH (-2~16) / ORP (-1999~1999mV) / temperature (-10~130℃/14~266℉)…
the expression says that this model can use for PH and ORP.
Is this right or is it used only for PH measurement?
I am confused, please inform me.
Was this review helpful? Yes No (0/0)
ATO Responded
We confirm that this model can use for PH and ORP, and the Digital pH/ORP meter is generally generic.
Some questions about the pH meter
5
lily
Avatar
9/4/2023 9:45 PM
1.I would like to know the type of controller they refer to according to the pH meter that was purchased.
2. I would also like to know how I can test the pH meter with a multimeter to verify that it is working correctly.
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, you can Not test the pH meter with a multimeter to verify that it is working correctly, only with standard solutions. You can refer to the user manual of the attached pH meter.
Consult for the PH devices
5
Noah
Avatar
2/5/2024 12:45 AM
I’m and engineer consultant with Exponent and I have a client who is interested in some of ATO’s products. Overall, my client is looking for a system to track pH in a residential drinking water pipe (1 to 1.5 in). Conceptually, the pH probe will be located inside the pipe and pH measurements should be taken every 6 to 10 minutes. The pH data will be transmitted to a digital meter that should contain a recorder (memory card) to save the data. The system must have an easy operation that allows for probe calibration.

I believe ATO’s Digital pH Meter and ATO’s pH electrode for Pure Water are suitable for the job. As an advisor to the client, I would appreciate clarifications to the questions below.

Questions about the system:
Does your company provide one compiled system where the digital meter and the pH probe are all one piece instead of two different parts?

What is the electricity demand of the system (e.g. probe and digital meter)?
Do you provide a system where the data is transmitted remotely instead of having a memory stick?

Questions about installation:
Does your company provide a fitting (mounts) to the pipe where the probe will be located? Can the probe be easily removed for cleaning/calibration purposes?
How are the connection between the digital meter and the pH probe?
How far apart can the probe be from the digital meter?

Questions about maintenance:
How often does the pH probe needs to be calibrated? How often do they have to be cleaned?
How fast will the memory stick be filled up?

Thank you and I look forward to hearing back from you.
Was this review helpful? Yes No (0/0)
ATO Responded
1. We can Not provide compiled systems, the digital meter and pH probe are both separate and are different components.

2. The power supply of the probe and digital instrument is 220V or 24V.

3. For remote data, you can use 485 or analog.

4. It can be equipped with a threaded base and is easy to disassemble.

5. The digital meter and pH probe are screwed together.

6. The distance between the probe and the digital instrument can be connected through a cable, and the longest distance does not exceed 40 meters.

7. The frequency of calibration depends on the water quality, usually once a month.

8. The memory module will be filled up depending on how long it is set, and it will be displayed on the meter.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Digital pH meter is an intelligent industrial online pH controller for testing/monitoring/recording water or food pH value, ORP value and temperature value.

Application:
Digital pH/ORP meter is widely used in the continuous testing and monitoring of pH, ORP and temperature in thermal power, chemical fertilizer, metallurgy, environmental protection, pharmaceutical, biochemical, food, drinking water, etc.

Function:

  • 4.3 inch LCD display
  • Good anti-interference performance
  • Manual/automatic temperature compensation
  • User settings: Buzzer, LCD backlight, password, pH/ORP electrode, manual/automatic temperature compensation, pH/ORP calibration, pH/ORP modification, pH/ORP high/low alarm, output signal 4-20mA and RS485, etc.
  • Data record function
  • Automatic cleaning function

Specification:

ModelATO-PHCR-PH8.5
Weight1kg
Dimension144*144*115mm (H*W*D) with hole size 138*138mm
Display4.3 inch LCD color screen
Measuring rangepH/Antimony: -2.00 ~ +16.00pH
ORP: -2000 ~ +2000mV
Temperature: -10.0 ~ +130.0℃
AccuracypH:±0.02pH
Antimony: ±0.2pH
ORP: ±2mV
Temperature:
NTC10K: ±0.3℃ (-10~+60℃), ±2.0℃ (60~130℃)
PT1000/PT100: ±0.3℃
Input impedance≥1012Ω
ResolutionpH/Antimony: 0.01pH
ORP: 1mV
Temperature range0~100℃ (NTC 10K, accuracy: ±0.5℃)
Repeatability0.02pH
Temperature compensationCompensation mode: Manual/Automatic
Compensation curve: Linear, Acid, Base, Pure
Record100 sets, recording interval can be set through configuration, the recording method is FIFO.
Output signal *Isolated 4-20mA signal (error: ±0.2%, under maximum loop resistance 750Ω), default 1 * 4-20mA output, optional 2 * 4-20mA outputs
Communication functionRS485 with standard MODBUS-RTU (Now RS485 software is free.)
Power supplyAC: 85~265V, 50Hz/60Hz
DC: 21.6~26.4V
Alarm relay delay0~9999 seconds, adjustable
Protection classIP66
Operating temperatureTemperature: 0~60℃
Relative Humidity: 10~85%RH (no condensing)
Storage conditionTemperature: -15~+65℃
Relative Humidity: 5~95%RH (no condensing)
Automatic cleaning *Manually clean, set cleaning interval

The pH meter and pH/ORP electrode selection:

pH meterpH/ORP electrodeIndustryTemperature rangeAdvantage
ATO-PHCR-PH8.0Combination pH electrodeSewage disposal0-60℃ (32-140℉)Combination electrode has automatic temperature compensation function, suitable for occasions with large temperature fluctuations.
Pure water pH electrodeDrinking water0-60℃ (32-140℉)The pH calomel electrode can be used in strong acid or alkali.
PTFE pH electrodeChemical0-60℃ (32-140℉)The electrode shell is made of PTFE, suitable for corrosive solution (strong acid or alkali), has longer life in harsh environments.
pH glass electrodeSewage disposal / food0-95℃ (32-203℉)Direct lead, double-layer glasses.
Desulfurization pH electrodeDesulfurization0-60℃ (32-140℉)Flat electrode, strong anti-pollution ability and longer life
High temperature/sterilization pH electrodeFood0-130℃ (32-266℉)The electrode can withstand high temperature of 0-130℃, suitable for occasions of high temperature sterilization in pharmaceutical factories, breweries, etc.
High pressure/accuracy pH electrodeLaboratory0-80℃ (32-176℉)Its linearity and accuracy are higher than all above electrodes.

Wiring diagram:
Digital online water/food pH/ORP meter wiring diagram
Definition of the ports:

  1. INPUT: Measuring terminal of the pH/ORP/Antimony electrode
  2. NC: Undefined
  3. REF: Reference terminal of the pH/ORP/Antimony electrode
  4. NC: Undefined
  5. TEMPA: Temperature compensation terminal A
  6. TEMPB: Temperature compensation terminal B
  7. TEMPC: Temperature compensation terminal C
  8. RS485 (A+): RS485 communication interface A+
  9. RS485 (B-): RS485 communication interface B-
  10. 0/4-20mA (A+): A current output terminal +
  11. 0/4-20mA (A/B-): A/B current output terminal -
  12. 0/4-20mA (B+): B current output terminal +
  13. WASH: Cleaning device relay
  14. WASH: Cleaning device relay
  15. REL B: Alarm relay B
  16. REL B: Alarm relay B
  17. REL A: Alarm relay A
  18. REL A: Alarm relay A
  19. POWER N: AC 220V/110V neutral wire
  20. POWER L: AC 220V/110V live wire

Communication:
RS485 communication data and register address as follows:

AddressAccess authorityData typeData typeFunction codeExplanation
0x0001Read onlyFloat40x03pH/ORP/Antimony electrode measurement value
0x0003Read onlyFloat40x03Temperature measurement value

Tips: How to control the pH value to be 6-9 with a pH meter?
The pH electrode with submersible installation is submerged in the alkali pool to test the pH value. The lower limit alarm relay of the pH meter is connected to a solenoid valve (normally closed solenoid valve).
First, set the lower alarm value to be 6 for closed and 7 for open, when the pH value is below 6, the alarm relay is closed and the dosing pump works to add lye to the pool. When pH value in the pool reaches 7, the alarm relay is closed, and the dosing pump stops to add lye.
Second, set the upper alarm value to be 9 for closed and 8 for open, when the pH value is above 9, the alarm relay is closed and the dosing pump works to add acid liquor to the pool. When pH value in the pool reaches 8, the alarm relay is close and the dosing pump stops to add acid liquor.
Through the alarm return difference, pH value will be controlled between 6 and 9.

Product reviews
The measured data of pH meter is very close to the theoretical value.
5
Kraus
Avatar
10/20/2018 12:51 AM
Digital pH meter is very practical and convenient to carry to other place. The pH meter has high accuracy. The measured data is very close to the theoretical value.
Was this review helpful? Yes No (0/0)
Online pH meter
5
Terrence
Avatar
3/30/2021 2:21 AM
Dear Sir,
Please recommend an online pH meter, with accessory/electrode for continuous testing tape water.  Please quote CIP Hong Kong.  thanks Terrence.
Was this review helpful? Yes No (0/0)
ATO Responded
We recommend this digital pH meter with SKU ATO-PHCON-PH160, and its corresponding product link https://www.ato.com/ph-electrode-for-pure-water. You can click on the product link to see the details.
Can this pH meter be use for PH and ORP?
5
landon
Avatar
7/31/2023 12:01 AM
When I check from the website https://www.ato.com/digital-ph-meter, Digital pH/ORP meter can be used with various pH electrodes or ORP electrodes to realize online testing and monitoring of pH (-2~16) / ORP (-1999~1999mV) / temperature (-10~130℃/14~266℉)…
the expression says that this model can use for PH and ORP.
Is this right or is it used only for PH measurement?
I am confused, please inform me.
Was this review helpful? Yes No (0/0)
ATO Responded
We confirm that this model can use for PH and ORP, and the Digital pH/ORP meter is generally generic.
Some questions about the pH meter
5
lily
Avatar
9/4/2023 9:45 PM
1.I would like to know the type of controller they refer to according to the pH meter that was purchased.
2. I would also like to know how I can test the pH meter with a multimeter to verify that it is working correctly.
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, you can Not test the pH meter with a multimeter to verify that it is working correctly, only with standard solutions. You can refer to the user manual of the attached pH meter.
Consult for the PH devices
5
Noah
Avatar
2/5/2024 12:45 AM
I’m and engineer consultant with Exponent and I have a client who is interested in some of ATO’s products. Overall, my client is looking for a system to track pH in a residential drinking water pipe (1 to 1.5 in). Conceptually, the pH probe will be located inside the pipe and pH measurements should be taken every 6 to 10 minutes. The pH data will be transmitted to a digital meter that should contain a recorder (memory card) to save the data. The system must have an easy operation that allows for probe calibration.

I believe ATO’s Digital pH Meter and ATO’s pH electrode for Pure Water are suitable for the job. As an advisor to the client, I would appreciate clarifications to the questions below.

Questions about the system:
Does your company provide one compiled system where the digital meter and the pH probe are all one piece instead of two different parts?

What is the electricity demand of the system (e.g. probe and digital meter)?
Do you provide a system where the data is transmitted remotely instead of having a memory stick?

Questions about installation:
Does your company provide a fitting (mounts) to the pipe where the probe will be located? Can the probe be easily removed for cleaning/calibration purposes?
How are the connection between the digital meter and the pH probe?
How far apart can the probe be from the digital meter?

Questions about maintenance:
How often does the pH probe needs to be calibrated? How often do they have to be cleaned?
How fast will the memory stick be filled up?

Thank you and I look forward to hearing back from you.
Was this review helpful? Yes No (0/0)
ATO Responded
1. We can Not provide compiled systems, the digital meter and pH probe are both separate and are different components.

2. The power supply of the probe and digital instrument is 220V or 24V.

3. For remote data, you can use 485 or analog.

4. It can be equipped with a threaded base and is easy to disassemble.

5. The digital meter and pH probe are screwed together.

6. The distance between the probe and the digital instrument can be connected through a cable, and the longest distance does not exceed 40 meters.

7. The frequency of calibration depends on the water quality, usually once a month.

8. The memory module will be filled up depending on how long it is set, and it will be displayed on the meter.
Only registered users can write reviews
Customers who bought this item also bought

PTFE pH Electrode for Strong Acid and Alkali

ATO-PHELE-5013A
$179.92
PTFE pH electrode for strong acid and alkali, PTFE shell, good corrosion resistance, 0-60℃ (32-140℉) temperature range, direct lead, 6 months service life.

Portable Digital Soil Moisture Meter

ATO-MM-PMS710
$338.46
Buy soil moisture meter for indoor plants, price cheap, measuring range 0-50%, digital LCD display is easy to observe at any time, it is a portable, sensitive moisture meter, insert 1/3 of the probe into the soil to measure, manufacturer direct sales.

High Temperature pH Probe Electrode for Sterilization

ATO-SIN-PH-5015
$525.77
High temperature pH probe electrode for sale, measuring range 0-14pH, temperature range 0~130°C and pressure resistance up to 0.6Mpa. pH probe electrode for sterilization with upper thread PG13.5, its salt bridge adopt porous ceramic core. pH meter electrode with optional insertion depth 120/150/225/325/425mm, apply in pharmaceuticals, food and beverage, microbiology, technology, sugar, mining and smelting.

Combination pH Electrode for Wastewater Treatment

ATO-PHELE-5011
$208.31
This pH electrode product is a bright eye for detecting water quality on Earth. It is independently developed and has a rapid and sensitive response. Online pH meters have advantages such as anti-interference, high accuracy, and good stability.