The pH glass electrode with sensitive glass bulb has two glass laminating, glass shell, 0-100℃ (32-212℉) temperature range, direct lead wire, 6 months service life.
SKU: ATO-PHELE-5018
*
*
Free Shipping
Delivery date: 6-12 days

The pH glass electrode can be widely used for wastewater treatment, pure water industry, strong acid and alkali harsh environment.

Function:

  • Adopt sensitive glass bulb with area 217.6 square millimeter, five layers of glass-film.
  • Shell material is special glass, high temperature resistant, high pressure resistant, increase 30% impact resistance strength.
  • External reference electrode increases Ag+, prevent salt bridge blockage, ensure accurate output signal and longer service life.
  • Accessories: PTFE sheath or stainless steel sheath. Increase the acid and alkali resistance of the electrode, easy to install.
  • High-quality low-noise cable, can achieve 60m long distance signal transmission.

Specification:

ModelATO-PHETE-PH5018
Weight1kg
Measuring range0-14pH
Accuracy0.02pH
Temperature range0-100℃ (32-212℉)
Temperature compensation *Internal temperature sensor (NTC 10K, Pt100, Pt1000)
Zero position7±0.5pH
Compressive strength0.4MPa
Slope≥98% (25℃)
Installation sizePG13.5 pipe thread
Shell materialGlass
Film resistance<250MΩ
Response time<1min
ConnectionDirect lead wire
Cable length *5m/10m/15m, or other length less than 50m (need customization)
Service life6 months

Specification of sheaths (optional accessories):

ModelATO-PHETE-A1ATO-PHETE-A2
Internal threadPG13.5 pipe threadPG13.5 pipe thread
External thread3/4NPT3/4NPT
MaterialPTFE (Polytetrafluoroethylene)Stainless steel

The pH electrod installation methods:
PH electrod installation methods
1. Side wall installation (*The pH electrode must be at an angle of 15 degrees to the liquid surface. Otherwise, it will affect the normal use of the pH electrode.)
2. Flange mounted at the top
3. Pipe installation
4. Top installation
5. Submersible installation
6. Flow-through installation

Tips: Cautions for use
pH electrode is an electrochemical consumable, it's different from instrument apparatus. Only mastering necessary maintenance knowledge can users prolong the service life of pH electrode.

  1. Clean the electrode with distilled water or deionized water before measurement, and then dry water with filter paper, so as to avoid impurities from entering the solution. Electrode bulb and liquid junction boarder shall be soaked in the measured liquid synchronously.
  2. The electrode shall be cleaned when not being used, and placed in the protective sleeve with saturated potassium chloride solution, or placed in the container with saturated potassium chloride solution.
  3. Check whether the terminals are dry. If they are polluted, wipe with anhydrous alcohol and dry before use.
  4. Avoid the electrode to be soaked in the distilled water or protein solution for a long time, avoid it from being contacted with silicone grease.
  5. Glass film of the electrode used for long time may become translucent or have sediments, wash it with dilute hydrochloric acid and wash with water.
  6. Users shall clean the pH electrode once a month and calibrate it with instrument.
  7. If the electrode can’t be normally calibrated or measured after maintaining with above methods, that means the electrode has been unable to restore its response, change a pH electrode timely.
Product reviews
Long service life
5
Logan
Avatar
10/25/2018 8:14 PM
The pH glass electrode has a high enough accuracy. And most of all, the pH electrode has a really long service life. We have purchased many times for its high cost-effective.
Was this review helpful? Yes No (0/0)
Durable pH glass electrode
5
Johanes
Avatar
12/1/2022 12:17 AM
I use this pH glass electrode to measure pH of irrigation and feeding mixtures in a greenhouse, usually ranging between 7.6 and 5.2. It's accurate enough for those purposes and pretty darn durable.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The pH glass electrode can be widely used for wastewater treatment, pure water industry, strong acid and alkali harsh environment.

Function:

  • Adopt sensitive glass bulb with area 217.6 square millimeter, five layers of glass-film.
  • Shell material is special glass, high temperature resistant, high pressure resistant, increase 30% impact resistance strength.
  • External reference electrode increases Ag+, prevent salt bridge blockage, ensure accurate output signal and longer service life.
  • Accessories: PTFE sheath or stainless steel sheath. Increase the acid and alkali resistance of the electrode, easy to install.
  • High-quality low-noise cable, can achieve 60m long distance signal transmission.

Specification:

ModelATO-PHETE-PH5018
Weight1kg
Measuring range0-14pH
Accuracy0.02pH
Temperature range0-100℃ (32-212℉)
Temperature compensation *Internal temperature sensor (NTC 10K, Pt100, Pt1000)
Zero position7±0.5pH
Compressive strength0.4MPa
Slope≥98% (25℃)
Installation sizePG13.5 pipe thread
Shell materialGlass
Film resistance<250MΩ
Response time<1min
ConnectionDirect lead wire
Cable length *5m/10m/15m, or other length less than 50m (need customization)
Service life6 months

Specification of sheaths (optional accessories):

ModelATO-PHETE-A1ATO-PHETE-A2
Internal threadPG13.5 pipe threadPG13.5 pipe thread
External thread3/4NPT3/4NPT
MaterialPTFE (Polytetrafluoroethylene)Stainless steel

The pH electrod installation methods:
PH electrod installation methods
1. Side wall installation (*The pH electrode must be at an angle of 15 degrees to the liquid surface. Otherwise, it will affect the normal use of the pH electrode.)
2. Flange mounted at the top
3. Pipe installation
4. Top installation
5. Submersible installation
6. Flow-through installation

Tips: Cautions for use
pH electrode is an electrochemical consumable, it's different from instrument apparatus. Only mastering necessary maintenance knowledge can users prolong the service life of pH electrode.

  1. Clean the electrode with distilled water or deionized water before measurement, and then dry water with filter paper, so as to avoid impurities from entering the solution. Electrode bulb and liquid junction boarder shall be soaked in the measured liquid synchronously.
  2. The electrode shall be cleaned when not being used, and placed in the protective sleeve with saturated potassium chloride solution, or placed in the container with saturated potassium chloride solution.
  3. Check whether the terminals are dry. If they are polluted, wipe with anhydrous alcohol and dry before use.
  4. Avoid the electrode to be soaked in the distilled water or protein solution for a long time, avoid it from being contacted with silicone grease.
  5. Glass film of the electrode used for long time may become translucent or have sediments, wash it with dilute hydrochloric acid and wash with water.
  6. Users shall clean the pH electrode once a month and calibrate it with instrument.
  7. If the electrode can’t be normally calibrated or measured after maintaining with above methods, that means the electrode has been unable to restore its response, change a pH electrode timely.
Product reviews
Long service life
5
Logan
Avatar
10/25/2018 8:14 PM
The pH glass electrode has a high enough accuracy. And most of all, the pH electrode has a really long service life. We have purchased many times for its high cost-effective.
Was this review helpful? Yes No (0/0)
Durable pH glass electrode
5
Johanes
Avatar
12/1/2022 12:17 AM
I use this pH glass electrode to measure pH of irrigation and feeding mixtures in a greenhouse, usually ranging between 7.6 and 5.2. It's accurate enough for those purposes and pretty darn durable.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

Industrial pH/ORP Meter for Water

ATO-PHM-163S
$271.78
Low price pH/ORP meter is specially designed for water testing and can detect and monitor pH (0~14pH) and ORP (-1000~1000mV) of sewage. Recommended industrial pH detector is equipped with an optional 5m sewage combination electrode/glass electrode/electroplating electrode/PTFE electrode/desulfurization electrode, which can be used in sewage treatment, dosing control, desulfurization chemical industry, printing and dyeing industry, waste gas treatment, and electroplating industry.

pH Controller, Transmit pH/ORP, Water/Food Process

ATO-PHM-PH6
$327.62
pH/ORP controller can be connected with alarm relays and solenoid valves to form a simple pH/ORP process control system. Digital pH meter can be used with various pH electrodes or ORP electrodes to realize online continuous testing and monitoring of the pH (0~14) / ORP (-1000~1000mV) / temperature (-10~+130℃/14~266℉) of sewage, corrosive solution, liquid medicine, beer, drinking water, food, high temperature sterilization occasions, etc. pH controller transmits standard output signal 4-20mA to digital panel meter/VFD/PLC/recorder, or RS485 signal to computer for remote monitoring and recording.