Magnetic Wastewater Flow Meter, DN15/DN50/DN100-DN200

$842.03
Magnetic flow meter or electromagnetic meters for all conductive liquids like wastewater/sewage water, nominal diameter DN15, DN20, DN25, DN32, DN50, DN100, DN125, DN150, DN200 for choice, supply voltage 110V AC, 220V AC or 24V DC, output signal 4-20mA, flange mounting, with integral and remote structure design, small pressure loss, high precision and reliability, good compatible with all kinds of pipes, etc.
SKU: ATO-FLOW-MAG
*
*
*
Free Shipping
Delivery date: 8-12 days

Electromagnetic flowmeters/ magnetic flow meters with DN15~DN200 are applicable for all conductive liquids, such as domestic water, industrial water, raw water, ground water, urban sewage, industrial wastewater, the processed neutral pulp, pulp slurry, etc.

Specification

ModelATO-LDG
MediumConductivity fluid (≥5uS/cm)
Nominal Diameter *DN15~DN200
Nominal Pressure1.6MPa
Velocity Range0~10m/s
Accuracy±0.5%R
ConfigurationIntegral type or split type
Note: The main difference between integral and split flowmeters is temperature and pressure compensation. The split type is to install the flowmeter and temperature/pressure transmitter separately, and the integral type is to install the temperature/pressure transmitter integratedly.
Highest Medium TemperatureIntegral type+80°C
Split type+80°C (CR) or +120°C (F4)
Turn-down RatioIntegral type20:1
Split type10:1
Ambient TemperatureSensor-25°C~+180°C
Convertor-10°C~+60°C
Liner Materials *Chloroprene rubber (CR) or Polytetrafluoroethylene (F4)
(Customized materials: Polyurethane rubber PU, F46)
Electrode Material *Stainless steel 316L
(Customized electrode: Hastelloy C, Hastelloy B, Titanium, Tantalum, Platinum)
Form of ElectrodeInterpolating
Number of ElectrodesStandard configuration 3-4 electrodes (two measuring electrodes plus a grounding electrode)
Output Signal4-20mA
Cable Entry SizeM20 × 1.5 (Nylon waterproof connector)
Supply Voltage*110V/220V AC, 50Hz/60Hz; 24V DC ±10%
Power Dissipation≤15VA
CommunicationRS-485, support standard Modbus-RTU protocol
Flange StandardConform to the international GB9119
Flange MaterialCarbon steel
Grounding Ring MaterialStainless steel
Housing MaterialCarbon steel
Protection LevelIP65
Cable Length (Remote Type)10m connecting line (Standard)

Note:
*Please note that all the options may not listed in the selecting area, including the nominal diameter, liner materials, electrode materials and so on. If your have any requirements, please contact us.

Mag Flowmeter Flow Rate

Magnetic Flow Meter DN and Flow Rate Table

Dimensions (unit: mm)

Magnetic flowmeter flange configuration dimensions

DNa∅D∅Don∅A
1520095654*14
20200105754*14
25200115854*14
322001401004*18
402001501104*18
502001651454*18
652501851458*18
802502001608*18
1002502201808*18
1252502502108*18
1503002852408*22
2003503402958*22


Electromagnetic Flow Meter Installation Notes

  1. Electromagnetic flow meter should be installed in the horizontal pipeline lower and vertically upward, avoid installation in the pipeline on the highest point and vertically downward.
  2. It should be installed at the rising point of the pipeline.
  3. In the open discharge pipeline installation, should be installed in the lower part of the pipeline.
  4. If the pipe drop is more than 5m, install an exhaust valve downstream of the sensor.
  5. The sensor of the flow meter should never be installed at the inlet of the pump, and should be installed at the outlet of the pump.
  6. It should be noted that there should be at least 10*D (D is the inner diameter of the flow meter) length of straight pipe section in front of the flow meter, and 5*D length of straight pipe section at the back.

Applications

LDG-MK electromagnetic flow meter is a powerful guarantee for water pollution control, with accurate and reliable measurement performance.

Electromagnetic flow meter applications

Tips: What is an electromagnetic flow meter? What are the characteristics?

A magnetic flowmeter or electromagnetic flowmeter is an instrument, based on the principle of electromagnetic induction, to measure the flow rate of a conductive fluid by the electromotive force induced by the conductive fluid going through an external magnetic field. The structure of the magnetic flowmeter is mainly composed of magnetic circuit system, measuring conduit, electrodes, housing, liner, and converter.

Magnetic Flowmeter Features:

  1. The measurement is not affected by changes in fluid density, viscosity, temperature, pressure and conductivity.
  2. There is no component to obstruct the flow in the measuring tube without pressure loss and with low requirement for the straight pipe section.
  3. If choosing reasonable sensor lining and electrode material, the magnetic flowmeter will has good corrosion resistance and abrasion resistance.
  4. The converter uses a novel excitation method, featuring low power consumption, zero point stability, high accuracy.
  5. The converter can be integrated with the sensor, i.e. integral type or be separated from the sensor, i.e. remote type.
  6. The sensor’s induced voltage signal is linearly related to the average flow velocity, so the measurement accuracy is high.

Flow Meter Pre-shipment Test

Every flow meter is subjected to a variety of tests before it is sent to the customer, and this video provides a brief overview of some of the immunization tests performed on flow meters.

Applications and importance of flow meters

This video talks about the application and importance of flow meters. And you can contact us for customization.

Application of Magnetic Flow Meters in Mining Metal Beneficiation

ATO's magnetic flowmeters provide a powerful and accurate solution for measuring the flow of highly abrasive slurries in mine dewatering and slurry measurement.

Magnetic Flow Meter Used in Beer Brewing

In this video, the use of magnetic flow meters in beer brewing is introduced.

Electromagnetic Flow Meter Calibration Tools Overview

In this video, an overview of electromagnetic flow meter calibration tools is given.

Product reviews
This mag flow meter works perfect.
5
Johnson
Avatar
10/23/2018 7:54 PM
Bought this magnetic flow meter for measuring the wastewater, and it was mounted easily with flange. The split type is really convenient for me to operate this item and measure the wastewater. Works perfect.
Was this review helpful? Yes No (0/0)
Best magnetic flow meter I've ever used
5
Glenny
Avatar
11/3/2022 11:51 PM
This is the best magnetic flow meter I've ever used. Not only is it affordable, but most importantly, it performs well. I have been using this magnetic flow meter for five months without any problems.
Was this review helpful? Yes No (0/0)
We would like to know if this flow meter can work properly under pressures higher than atmospheric pressure
5
Jackson
Avatar
3/3/2023 12:21 AM
What we found is that the flow meter displays a much lower flowrate number when it is connected behind a pump. So, we would like to know if this flow meter can work properly under pressures higher than atmospheric pressure.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the flow meter is connected to the back of the pump, the pump will have pressure loss, and the overall pressure in the pipeline will drop, so the flow meter displays a much lower flowrate number.

When installing, please try to make the straight pipe between the pump and the flowmeter as long as possible, about half a meter would be better. This flow meter can work normally at pressures above atmospheric pressure.
Recommended flow meter
4
Ursina
Avatar
5/18/2025 8:05 PM
I am researching the use of electromagnetic flowmeters to measure gasoline, diesel, and aviation fuel with additives such as ethanol and butane. We currently use turbine flowmeters and are looking for a more accurate and economical method of measurement. Do you have any recommendations?
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, you can see if our magnetic wastewater flow meter meets your requirements, SKU: ATO-FLOW-MAG. In addition, please tell us the maximum pressure level for loading gasoline and diesel, the installation diameter of the flowmeter, whether explosion-proof is required, etc.
Flow meter requirements
5
Keske
Avatar
7/2/2026 12:23 AM
I need a flow meter with the following details: Medium: Water; Flow meter size: Suitable for installation between a circulating chiller and a thermal storage tank. The chiller connection piping/hose size is expected to be approximately 1/2 inch to 1 inch. Please recommend the most suitable flow meter size for this application. Flow range: Up to 50 liters/minute (if possible); Ambient temperature: Approximately 25–30°C; Operating pressure: Up to 5 bar.
Was this review helpful? Yes No (0/0)
ATO Responded
We need you to confirm whether the flow meter diameter is 1/2 inch or 1 inch. The required flow meter diameter is 1 inch. You can refer to our ATO-LDG flow meter to see if it meets your requirements. Note: Your site uses a hose, so you will need to add a straight section of pipe.
Stainless steel material
5
Nautia
Avatar
9/18/2026 2:19 AM
Is the ATO-FLOW-MAG made of stainless steel? Is the material SS304 or SS316?
Was this review helpful? Yes No (0/0)
ATO Responded
Its flange and housing are made of carbon steel; if you require customization with 304 stainless steel, a new quote will be necessary.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Electromagnetic flowmeters/ magnetic flow meters with DN15~DN200 are applicable for all conductive liquids, such as domestic water, industrial water, raw water, ground water, urban sewage, industrial wastewater, the processed neutral pulp, pulp slurry, etc.

Specification

ModelATO-LDG
MediumConductivity fluid (≥5uS/cm)
Nominal Diameter *DN15~DN200
Nominal Pressure1.6MPa
Velocity Range0~10m/s
Accuracy±0.5%R
ConfigurationIntegral type or split type
Note: The main difference between integral and split flowmeters is temperature and pressure compensation. The split type is to install the flowmeter and temperature/pressure transmitter separately, and the integral type is to install the temperature/pressure transmitter integratedly.
Highest Medium TemperatureIntegral type+80°C
Split type+80°C (CR) or +120°C (F4)
Turn-down RatioIntegral type20:1
Split type10:1
Ambient TemperatureSensor-25°C~+180°C
Convertor-10°C~+60°C
Liner Materials *Chloroprene rubber (CR) or Polytetrafluoroethylene (F4)
(Customized materials: Polyurethane rubber PU, F46)
Electrode Material *Stainless steel 316L
(Customized electrode: Hastelloy C, Hastelloy B, Titanium, Tantalum, Platinum)
Form of ElectrodeInterpolating
Number of ElectrodesStandard configuration 3-4 electrodes (two measuring electrodes plus a grounding electrode)
Output Signal4-20mA
Cable Entry SizeM20 × 1.5 (Nylon waterproof connector)
Supply Voltage*110V/220V AC, 50Hz/60Hz; 24V DC ±10%
Power Dissipation≤15VA
CommunicationRS-485, support standard Modbus-RTU protocol
Flange StandardConform to the international GB9119
Flange MaterialCarbon steel
Grounding Ring MaterialStainless steel
Housing MaterialCarbon steel
Protection LevelIP65
Cable Length (Remote Type)10m connecting line (Standard)

Note:
*Please note that all the options may not listed in the selecting area, including the nominal diameter, liner materials, electrode materials and so on. If your have any requirements, please contact us.

Mag Flowmeter Flow Rate

Magnetic Flow Meter DN and Flow Rate Table

Dimensions (unit: mm)

Magnetic flowmeter flange configuration dimensions

DNa∅D∅Don∅A
1520095654*14
20200105754*14
25200115854*14
322001401004*18
402001501104*18
502001651454*18
652501851458*18
802502001608*18
1002502201808*18
1252502502108*18
1503002852408*22
2003503402958*22


Electromagnetic Flow Meter Installation Notes

  1. Electromagnetic flow meter should be installed in the horizontal pipeline lower and vertically upward, avoid installation in the pipeline on the highest point and vertically downward.
  2. It should be installed at the rising point of the pipeline.
  3. In the open discharge pipeline installation, should be installed in the lower part of the pipeline.
  4. If the pipe drop is more than 5m, install an exhaust valve downstream of the sensor.
  5. The sensor of the flow meter should never be installed at the inlet of the pump, and should be installed at the outlet of the pump.
  6. It should be noted that there should be at least 10*D (D is the inner diameter of the flow meter) length of straight pipe section in front of the flow meter, and 5*D length of straight pipe section at the back.

Applications

LDG-MK electromagnetic flow meter is a powerful guarantee for water pollution control, with accurate and reliable measurement performance.

Electromagnetic flow meter applications

Tips: What is an electromagnetic flow meter? What are the characteristics?

A magnetic flowmeter or electromagnetic flowmeter is an instrument, based on the principle of electromagnetic induction, to measure the flow rate of a conductive fluid by the electromotive force induced by the conductive fluid going through an external magnetic field. The structure of the magnetic flowmeter is mainly composed of magnetic circuit system, measuring conduit, electrodes, housing, liner, and converter.

Magnetic Flowmeter Features:

  1. The measurement is not affected by changes in fluid density, viscosity, temperature, pressure and conductivity.
  2. There is no component to obstruct the flow in the measuring tube without pressure loss and with low requirement for the straight pipe section.
  3. If choosing reasonable sensor lining and electrode material, the magnetic flowmeter will has good corrosion resistance and abrasion resistance.
  4. The converter uses a novel excitation method, featuring low power consumption, zero point stability, high accuracy.
  5. The converter can be integrated with the sensor, i.e. integral type or be separated from the sensor, i.e. remote type.
  6. The sensor’s induced voltage signal is linearly related to the average flow velocity, so the measurement accuracy is high.
Product reviews
This mag flow meter works perfect.
5
Johnson
Avatar
10/23/2018 7:54 PM
Bought this magnetic flow meter for measuring the wastewater, and it was mounted easily with flange. The split type is really convenient for me to operate this item and measure the wastewater. Works perfect.
Was this review helpful? Yes No (0/0)
Best magnetic flow meter I've ever used
5
Glenny
Avatar
11/3/2022 11:51 PM
This is the best magnetic flow meter I've ever used. Not only is it affordable, but most importantly, it performs well. I have been using this magnetic flow meter for five months without any problems.
Was this review helpful? Yes No (0/0)
We would like to know if this flow meter can work properly under pressures higher than atmospheric pressure
5
Jackson
Avatar
3/3/2023 12:21 AM
What we found is that the flow meter displays a much lower flowrate number when it is connected behind a pump. So, we would like to know if this flow meter can work properly under pressures higher than atmospheric pressure.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the flow meter is connected to the back of the pump, the pump will have pressure loss, and the overall pressure in the pipeline will drop, so the flow meter displays a much lower flowrate number.

When installing, please try to make the straight pipe between the pump and the flowmeter as long as possible, about half a meter would be better. This flow meter can work normally at pressures above atmospheric pressure.
Recommended flow meter
4
Ursina
Avatar
5/18/2025 8:05 PM
I am researching the use of electromagnetic flowmeters to measure gasoline, diesel, and aviation fuel with additives such as ethanol and butane. We currently use turbine flowmeters and are looking for a more accurate and economical method of measurement. Do you have any recommendations?
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, you can see if our magnetic wastewater flow meter meets your requirements, SKU: ATO-FLOW-MAG. In addition, please tell us the maximum pressure level for loading gasoline and diesel, the installation diameter of the flowmeter, whether explosion-proof is required, etc.
Flow meter requirements
5
Keske
Avatar
7/2/2026 12:23 AM
I need a flow meter with the following details: Medium: Water; Flow meter size: Suitable for installation between a circulating chiller and a thermal storage tank. The chiller connection piping/hose size is expected to be approximately 1/2 inch to 1 inch. Please recommend the most suitable flow meter size for this application. Flow range: Up to 50 liters/minute (if possible); Ambient temperature: Approximately 25–30°C; Operating pressure: Up to 5 bar.
Was this review helpful? Yes No (0/0)
ATO Responded
We need you to confirm whether the flow meter diameter is 1/2 inch or 1 inch. The required flow meter diameter is 1 inch. You can refer to our ATO-LDG flow meter to see if it meets your requirements. Note: Your site uses a hose, so you will need to add a straight section of pipe.
Stainless steel material
5
Nautia
Avatar
9/18/2026 2:19 AM
Is the ATO-FLOW-MAG made of stainless steel? Is the material SS304 or SS316?
Was this review helpful? Yes No (0/0)
ATO Responded
Its flange and housing are made of carbon steel; if you require customization with 304 stainless steel, a new quote will be necessary.
Only registered users can write reviews