Load Cell Weight Transmitter, Single Channel, 0-5V/0-10V/4-20mA

$123.87
The single channel load cell weight transmitter for sale at favorable price, as a new measurement and control device on ATO shop, can convert the analog signal of the load cell into standard analog signals such as 0-5V, 0-10V, 4-20mA and other standard analog signals to control the output, support V1+A1 synchronous output, improve compatibility, and be able to connect better with PLC and other industrial control equipment.
SKU: ATO-LCTR-NTB3K
*
*
*
Free Shipping
Delivery date: 6-12 days

The low cost ATO-NTB3K is in hot sale, as a high precision single-channel load cell weight transmitter, the signal output can be optional 0-5V/0-10V/4-20mA/0~±5V/0~±10V, ensuring the accurate data transmission. With IP65 protection, power supply voltage of 10-36VDC, compact and lightweight body, easy to be integrated into automation systems.

Note: Manual calibration is not supported. Please provide the load cell's capacity and sensitivity for factory calibration. This transmitter only supports fine adjustment.

Specification

ModelATO-NTB3K
Rated Input±20mV
Single Output (optional)V1: 0~5V
V2: 0~10V
V3: 0~±5V
V4: 0~±10V
A1: 4~20mA
Simultaneous output V1+A1
ChannelSingle channel
Precision≤±0.1%F-S
Supply Voltage10 (12) ~36V DC
Working Temperature-20°C~70°C
Protection LevelIP65
Size110*64*37mm
Net Weight≤0.5kg


Feature

  • Precision die-cast aluminum transmitter housing with plastic sprayed surface, suitable for high precision level and harsh environment.
  • Adopting anti-interference power supply design technology, the load cell weight transmitter has good electromagnetic compatibility (EMs).
  • The wiring adopts terminal and aviation plug, and there are mounting holes in the shell. In addition to the characteristics of a normal load cell transmitter, it also reduces the harmonic interference generated by frequency converters and so on.
  • The analog output of this load cell transmitter can be 0-5V, 0-10V, 0-±5V, 0-±10V, 4-20mA (optional).

Dimension (unit: mm)

Load cell weight transmitter dimension

Wiring Instruction

Load cell weight transmitter wiring instruction是

As the figure above shows: There are two wiring terminals J1 and J2 in the whole board diagram.

LEFT J1 is the terminal connecting the sensor:

PBConnect the sensor shielded wireblue wire
E+Connect the positive wire of the sensor excitation power supplyred wire
E-Connect the negative wire of the sensor excitation power supplyblack wire
S+Connect the positive wire of the sensor signal outputgreen wire
S-Connect the negative wire of the sensor signal outputwhite wire

RlGHT J2 is the terminal connecting the transmitter to the power supply and output:

IOUTConnect the transmitter current output positive wirewhite wire
VOUTConnect the positive voltage output wire of the transmitterwhite wire
(current and voltage are only output at the same time)
GNDConnect the negative wire of the transmitter power supplyblue wire
24VConnect the positive wire of the transmitter power supplyred wire

There are 2 adjustable resistors in the whole board diagram: RP2 is gain adjustment, RP1 is voltage zero adjustment.

Tips:  What are the common faults and troubleshooting methods of load cell weight transmitter?

Common faults include no signal output, unstable output signal or large error.

  1. No Signal Output: Check whether the power supply is normal, whether the wiring is correct, and whether the load cell transmitter is damaged.
  2. Unstable Signal: Check whether there is electromagnetic interference, whether the load cell sensor is subject to external vibration, and whether it is well grounded.
  3. Excessive Error: Is the calibration correct, is the sensor overloaded or damaged. Regular maintenance and calibration can ensure measurement accuracy and equipment stability.

Product reviews
Load cell transmitter recommendation
5
Penske
Avatar
3/13/2026 12:18 AM
We need four 20mA transmitters. Could you recommend one?
Was this review helpful? Yes No (0/0)
ATO Responded
What type of sensor transmitter do you need? What is the input signal to the transmitter?
Clean signal, no noise
5
Louis
Avatar
8/10/2026 6:58 PM
I had a noisy load cell signal before adding this transmitter. Now the 4‑20mA is steady and the PLC reads reliably. The 0.1% accuracy is good enough for our batching system.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The low cost ATO-NTB3K is in hot sale, as a high precision single-channel load cell weight transmitter, the signal output can be optional 0-5V/0-10V/4-20mA/0~±5V/0~±10V, ensuring the accurate data transmission. With IP65 protection, power supply voltage of 10-36VDC, compact and lightweight body, easy to be integrated into automation systems.

Note: Manual calibration is not supported. Please provide the load cell's capacity and sensitivity for factory calibration. This transmitter only supports fine adjustment.

Specification

ModelATO-NTB3K
Rated Input±20mV
Single Output (optional)V1: 0~5V
V2: 0~10V
V3: 0~±5V
V4: 0~±10V
A1: 4~20mA
Simultaneous output V1+A1
ChannelSingle channel
Precision≤±0.1%F-S
Supply Voltage10 (12) ~36V DC
Working Temperature-20°C~70°C
Protection LevelIP65
Size110*64*37mm
Net Weight≤0.5kg


Feature

  • Precision die-cast aluminum transmitter housing with plastic sprayed surface, suitable for high precision level and harsh environment.
  • Adopting anti-interference power supply design technology, the load cell weight transmitter has good electromagnetic compatibility (EMs).
  • The wiring adopts terminal and aviation plug, and there are mounting holes in the shell. In addition to the characteristics of a normal load cell transmitter, it also reduces the harmonic interference generated by frequency converters and so on.
  • The analog output of this load cell transmitter can be 0-5V, 0-10V, 0-±5V, 0-±10V, 4-20mA (optional).

Dimension (unit: mm)

Load cell weight transmitter dimension

Wiring Instruction

Load cell weight transmitter wiring instruction是

As the figure above shows: There are two wiring terminals J1 and J2 in the whole board diagram.

LEFT J1 is the terminal connecting the sensor:

PBConnect the sensor shielded wireblue wire
E+Connect the positive wire of the sensor excitation power supplyred wire
E-Connect the negative wire of the sensor excitation power supplyblack wire
S+Connect the positive wire of the sensor signal outputgreen wire
S-Connect the negative wire of the sensor signal outputwhite wire

RlGHT J2 is the terminal connecting the transmitter to the power supply and output:

IOUTConnect the transmitter current output positive wirewhite wire
VOUTConnect the positive voltage output wire of the transmitterwhite wire
(current and voltage are only output at the same time)
GNDConnect the negative wire of the transmitter power supplyblue wire
24VConnect the positive wire of the transmitter power supplyred wire

There are 2 adjustable resistors in the whole board diagram: RP2 is gain adjustment, RP1 is voltage zero adjustment.

Tips:  What are the common faults and troubleshooting methods of load cell weight transmitter?

Common faults include no signal output, unstable output signal or large error.

  1. No Signal Output: Check whether the power supply is normal, whether the wiring is correct, and whether the load cell transmitter is damaged.
  2. Unstable Signal: Check whether there is electromagnetic interference, whether the load cell sensor is subject to external vibration, and whether it is well grounded.
  3. Excessive Error: Is the calibration correct, is the sensor overloaded or damaged. Regular maintenance and calibration can ensure measurement accuracy and equipment stability.

Product reviews
Load cell transmitter recommendation
5
Penske
Avatar
3/13/2026 12:18 AM
We need four 20mA transmitters. Could you recommend one?
Was this review helpful? Yes No (0/0)
ATO Responded
What type of sensor transmitter do you need? What is the input signal to the transmitter?
Clean signal, no noise
5
Louis
Avatar
8/10/2026 6:58 PM
I had a noisy load cell signal before adding this transmitter. Now the 4‑20mA is steady and the PLC reads reliably. The 0.1% accuracy is good enough for our batching system.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

Tension/Compression Load Cell, Low Profile, 500kg/30 ton to 100 ton

ATO-LC-P02
$145.28
Low profile load cell also known as pancake load cell, has flat design, high strength and good symmetry. Tension and compression load cell can be applied for platform scale, truck scale, rail weighbridge and material level measurement and control in warehouse, with good anti-eccentric load performance, low height, all sealed structure and complete specifications.

Digital Load Cell Amplifier, Output 4-20mA/0-10V/RS485

ATO-LCTR-OAR
$109.85
High precision load cell amplifier has a 6 digit LED display, output signal 4-20mA/ 0-5V/ 0-10V/ RS485. There are 3 keys for parameter settings. Digital load cell amplifier can be calibrated on-line by its 3 keys. The setting parameters include zero, capacity, communication rate, division value, decimal digits, etc.

Strain Gauge Load Cell, S type, 5kg/50kg/1000kg/3 ton to 20 ton

ATO-LC-S01
$88.41
S type load cell can bear both tension and pressure, with good output symmetry, high accuracy, compact structure and complete specifications. Strain gauge load cell can be applied for batching scale, electronic-mechanical scale, crane scales and other force value measurement and control.

Compression Load Cell, 300kg/1000kg/25 ton/50 ton to 100 ton

ATO-LC-P01
$116.78
Compression load cell is special designed for weight measurement, with good anti-eccentric load performance, low height, all sealed, complete specifications, Load cell can be applied for platform scale, truck scale, rail weighbridge and material level measurement and control in warehouse.