Mechanical Limit Switch Box, 2-SPDT, IP67

$76.83
Mechanical limit switch box features a die-cast aluminum housing with a black polyester powder coating. The 2-SPDT mechanical microswitch offers precise control and is compatible with 250VAC/DC voltages. It comes with a special gift of a waterproof junction and cover to enhance the product’s waterproof capabilities. Optional activity mounts are available in two different materials. The limit switch box has a wide operating temperature range from -20℃ to +60℃.
SKU: ATO-LSB-ITS
*
*
Free Shipping
Delivery date: 6-12 days

This limit switch box features 2 single pole double throw (SPDT) switches, offering a choice between copper contact microswitches and silver contact microswitches. The included adjustable mounting bracket is available in either carbon steel or stainless steel material.

Specification

ModelATO-ITS-100
Voltage RangeMax 250VAC/DC
Rated CurrentDC 250V 0.3A
Microswitch Type2-SPDT Mechanical
Terminal Block8-position terminal, Copper core
Microswitch Contact (Optional)Copper / Silver contact microswitch
Threaded Interface2X G1/2" (M20*1.5)
Position IndicatorCLOSE (Red for Off), OPEN (Yellow for On)
Cam TypeCircular Cam, Red and yellow color
Shell MaterialDie-cast aluminum
Shell CoatingBlack, Polyester powder coating
Bracket StyleAdjustable mounting bracket
Bracket Material (Optional)Carbon steel with powder coating / Stainless steel
AccessoriesWaterproof junction and cover
Temperature-20℃~+60℃
Weight1000g
Protection ClassIP67

Explanation of parameters:

2-SPDT: There are two independent SPDT switching units, each with the following characteristics:
Single Pole (SP): Each switch has a movable contact which can be connected to one of two different circuits.
Double Throw (DT): Each switch has a contact that can be connected to one of two different contacts. These two contacts are usually referred to as Normally Open and Normally Closed.
Common (C): Contacts can be connected to this terminal.
Normally Open (NO): When the switch is not activated, the contacts are not connected to this terminal; when the switch is activated, the contacts are disconnected from Common and connected to Normally Open.
Normally Closed (NC): When the switch is not activated, the contacts are connected to this terminal; when the switch is activated, the contacts are disconnected from the normally closed terminal and connected to the common terminal.

Dimension (unit: mm)

Limit switch box dimension

Application

Limit switch box applications

Tips: 6 ways to maximize the performance of limit switch box

  1. Utilize the included adjustable mounting bracket, choosing either carbon steel or stainless steel to suit different installation environments. Ensure the switch box is securely fixed to avoid misoperation due to vibration.
  2. When wiring, make sure the copper core terminal blocks are securely connected to prevent poor contact due to looseness. Also, confirm that the voltage does not exceed 250VAC/DC to ensure safe operation of the switch.
  3. During installation, use the provided waterproof junction and cover to enhance the product’s waterproof capabilities, especially in humid or outdoor environments, to extend the lifespan of the switch box.
  4. This limit switch box is designed to operate within a temperature range of -20 to +60 degrees Celsius. Use it within this specified range to ensure the stability and reliability of the switch.
  5. Choose between copper contact microswitches and silver contact microswitches based on your specific application needs. Copper contacts are suitable for general industrial control situations, while silver contacts are better for precision equipment that requires high electrical conductivity and low contact resistance.
  6. Periodically inspect the switch box’s housing, contacts, and terminal blocks for any signs of wear, corrosion, or looseness. Address potential issues promptly to ensure the safe operation of your equipment.

VFD Emergency Stop with Limit Switches

In this video, you will learn about the setup and operation of emergency stopping a motor by using limit switches and a variable frequency drive (VFD). By combining the limit switches of the emergency stop function with the VFD GK3000, a strong safety measure can be established that can quickly stop the motor operation in an emergency.

Automatic Material Trolley Control with Limit Switch

In this video, the method of applying limit switches to automatic material trolley control is demonstrated.

Roller Limit Switch NO NC Contact Wiring and Detection

In this video, the roller limit switch NO NC contact wiring and detection operation are shown.

Product reviews
Mechanical limit switch
5
Nomis
Avatar
7/7/2025 8:10 PM
We are interested in similar products as ATO-LSB-ITS Mechanical Limit Switch Box (400°C - 2 hours): Mechanical Limit Switch Box, 2 Groups SPDT, IP67 Protection.
Was this review helpful? Yes No (0/0)
ATO Responded
It is only a mechanical limit switch box, not a limit switch itself. In addition, this device cannot withstand high temperatures, and its operating temperature range is -20℃ to 60℃.
Limit switch requirements
5
Hendry
Avatar
11/30/2025 8:03 PM
I need a limit switch box like this: 210N 250V, 3A / 125V, 5A (2 single-pole double-throw switches) IP67.
Was this review helpful? Yes No (0/0)
ATO Responded
You can refer to our mechanical limit switch box, 2-SPDT, IP67 protection rating, product number: ATO-LSB-ITS, rated current: DC 250V 0.3A, protection rating: IP67. Does it meet your needs?
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

This limit switch box features 2 single pole double throw (SPDT) switches, offering a choice between copper contact microswitches and silver contact microswitches. The included adjustable mounting bracket is available in either carbon steel or stainless steel material.

Specification

ModelATO-ITS-100
Voltage RangeMax 250VAC/DC
Rated CurrentDC 250V 0.3A
Microswitch Type2-SPDT Mechanical
Terminal Block8-position terminal, Copper core
Microswitch Contact (Optional)Copper / Silver contact microswitch
Threaded Interface2X G1/2" (M20*1.5)
Position IndicatorCLOSE (Red for Off), OPEN (Yellow for On)
Cam TypeCircular Cam, Red and yellow color
Shell MaterialDie-cast aluminum
Shell CoatingBlack, Polyester powder coating
Bracket StyleAdjustable mounting bracket
Bracket Material (Optional)Carbon steel with powder coating / Stainless steel
AccessoriesWaterproof junction and cover
Temperature-20℃~+60℃
Weight1000g
Protection ClassIP67

Explanation of parameters:

2-SPDT: There are two independent SPDT switching units, each with the following characteristics:
Single Pole (SP): Each switch has a movable contact which can be connected to one of two different circuits.
Double Throw (DT): Each switch has a contact that can be connected to one of two different contacts. These two contacts are usually referred to as Normally Open and Normally Closed.
Common (C): Contacts can be connected to this terminal.
Normally Open (NO): When the switch is not activated, the contacts are not connected to this terminal; when the switch is activated, the contacts are disconnected from Common and connected to Normally Open.
Normally Closed (NC): When the switch is not activated, the contacts are connected to this terminal; when the switch is activated, the contacts are disconnected from the normally closed terminal and connected to the common terminal.

Dimension (unit: mm)

Limit switch box dimension

Application

Limit switch box applications

Tips: 6 ways to maximize the performance of limit switch box

  1. Utilize the included adjustable mounting bracket, choosing either carbon steel or stainless steel to suit different installation environments. Ensure the switch box is securely fixed to avoid misoperation due to vibration.
  2. When wiring, make sure the copper core terminal blocks are securely connected to prevent poor contact due to looseness. Also, confirm that the voltage does not exceed 250VAC/DC to ensure safe operation of the switch.
  3. During installation, use the provided waterproof junction and cover to enhance the product’s waterproof capabilities, especially in humid or outdoor environments, to extend the lifespan of the switch box.
  4. This limit switch box is designed to operate within a temperature range of -20 to +60 degrees Celsius. Use it within this specified range to ensure the stability and reliability of the switch.
  5. Choose between copper contact microswitches and silver contact microswitches based on your specific application needs. Copper contacts are suitable for general industrial control situations, while silver contacts are better for precision equipment that requires high electrical conductivity and low contact resistance.
  6. Periodically inspect the switch box’s housing, contacts, and terminal blocks for any signs of wear, corrosion, or looseness. Address potential issues promptly to ensure the safe operation of your equipment.
Product reviews
Mechanical limit switch
5
Nomis
Avatar
7/7/2025 8:10 PM
We are interested in similar products as ATO-LSB-ITS Mechanical Limit Switch Box (400°C - 2 hours): Mechanical Limit Switch Box, 2 Groups SPDT, IP67 Protection.
Was this review helpful? Yes No (0/0)
ATO Responded
It is only a mechanical limit switch box, not a limit switch itself. In addition, this device cannot withstand high temperatures, and its operating temperature range is -20℃ to 60℃.
Limit switch requirements
5
Hendry
Avatar
11/30/2025 8:03 PM
I need a limit switch box like this: 210N 250V, 3A / 125V, 5A (2 single-pole double-throw switches) IP67.
Was this review helpful? Yes No (0/0)
ATO Responded
You can refer to our mechanical limit switch box, 2-SPDT, IP67 protection rating, product number: ATO-LSB-ITS, rated current: DC 250V 0.3A, protection rating: IP67. Does it meet your needs?