Hydrogen Sulfide (H2S) Monitor, 0 to 50/100/200 ppm

$216.84
With a measure range of 0 to 50 ppm, 0 to 100 ppm, 0 to 200 ppm, h2s detector offers the flexibility you need. Optional low alarm, high alarm ,working temperature -20℃~50℃, with a swift response time of under 10 seconds, you'll receive timely data.
SKU: GD800-H2S
*
Free Shipping
Delivery date: 6-12 days

The H2S monitor offers a reliable measurement range from 0 to 100 ppm, allowing you to accurately track H2S levels in your environment. Whether you need to monitor H2S levels in industrial settings, wastewater treatment plants, or confined spaces, our monitor is adaptable to various applications.

Specification

ModelGD800-H2S
Detected gasH2S
Sampling methodDiffusion
Range (optional)
0-50ppm, 0-10ppm, 0-200ppm
Resolution
0.1ppm
Response time≤10S
PrincipleElectrochemical principle
Alarm modeSound, light, vibration alarm, high and low alarm values can be set by yourself
Alarm typeLow alarm, high alarm, STEL, TWA, low battery
Explosion-proof gradeII 1G Ex da ia IIC T4 Ga
Protection classIP68
Working temperature-20℃~55℃
Working humidity0-95%RH (non-condensing)
Working air pressure86~106kpa
Dimensions90*60*33mm (length*width*thickness)
WeightWeight 125g

Note 1:

  • If you require an XX gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

Features

  • Rugged and Secure Design: H2S monitor is built to withstand challenging environments, with an IP68 protection rating that makes it splash-proof, dust-proof, explosion-proof, and shock-proof. Its intrinsically safe circuit design enhances safety in hazardous locations.
  • Customizable Alarm Settings: Throughout the device's lifespan, users have the flexibility to set alarm thresholds according to their specific needs. These settings include high point alarm, low point alarm, TWA, and STEL.
  • Enhanced Safety Features: H2S monitor features an automatic self-test function that continuously verifies its operational status, enhancing safety by providing ongoing self-assessment and reliability in safety-critical situations.
  • Exceptional Battery Life: With remarkably low power consumption, this detector offers a prolonged standby time of up to 2 years, eliminating the need for battery replacement.
  • Maintenance-Free Operation: H2S detector operates continuously without the need for calibration, sensor replacements, or battery charging, ensuring a hassle-free user experience.
  • User-Friendly and Portable: Designed with user-friendliness in mind, the device is compact and lightweight. It features an intuitive two-button operation that minimizes the need for extensive training.
  • Robust Alarm System: The device's alarm system includes an ultra-loud buzzer, two bright red LEDs for both upper and lower alarms, and a combination of sound, light, and vibration alerts. These features ensure that workers are quickly and effectively alerted to potential hazards.
  • Cost-Effective Solution: This detector is not only affordable but also offers a low total cost of ownership, making it a financially prudent choice.
  • Excellent Portability: With its small size and lightweight build, the device is highly portable, allowing for easy transport and deployment.
  • Durability: Crafted from high-strength materials, the device is designed to withstand harsh environmental conditions while ensuring user comfort and longevity.

Structure

Mini portable oxygen gas detector structureApplications

Hydrogen sulfide application

Tips: Why is H2S monitor important?

  1. Safety of Personnel: H2S is a highly toxic gas. Even at low concentrations, exposure to H2S can lead to various health problems, ranging from eye and respiratory irritation to more severe effects, such as nausea, dizziness, and in extreme cases, unconsciousness or even death. By monitoring H2S levels, you can ensure the safety of workers and prevent them from being exposed to hazardous concentrations.

  2. Legal and Regulatory Compliance: Many industries are subject to strict regulations regarding H2S exposure limits. Regulatory bodies set permissible exposure limits (PELs) to protect workers and the environment. Monitoring H2S is essential to maintain compliance with these regulations, helping to avoid legal consequences and fines for non-compliance.

  3. Emergency Response and Evacuation: In cases of sudden gas releases, such as leaks or chemical spills, an H2S monitor provides early detection, allowing for swift emergency responses. Evacuations and other safety measures can be initiated promptly, potentially preventing accidents or injuries.
  4. Health Surveillance: Regular monitoring provides data that can be used for health surveillance programs. It helps in tracking the long-term effects of H2S exposure on workers, enabling early intervention and health management.
  5. Confined Space Entry: In confined space work, where H2S can accumulate and pose immediate threats, monitoring is a fundamental safety practice. It allows personnel to confirm that conditions are safe for entry and to continuously assess the environment during work.

Basic Settings of Gas Detector

This video we're gonna guide you through some basic operational user functions.

How to Test a Small Handheld Single Gas Detector?

In this video, it is shown how to test a small handheld single gas detector. This is a simple safety device that everyone should have. It is small, easy to carry, lightweight and easy to use.

Product reviews
The H2S monitor for oilfield work
5
Elowen
Avatar
9/2/2025 12:30 AM
Great little safety tool!  I use the H2S monitor for oilfield work, and it's been reliable every day.  Simple two-button operation makes it easy, even with gloves on.  I really like that it automatically checks itself and has such a loud alarm system.  It feels durable but isn't bulky, so I don't mind carrying it all shift.  For the price, it's definitely worth it.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The H2S monitor offers a reliable measurement range from 0 to 100 ppm, allowing you to accurately track H2S levels in your environment. Whether you need to monitor H2S levels in industrial settings, wastewater treatment plants, or confined spaces, our monitor is adaptable to various applications.

Specification

ModelGD800-H2S
Detected gasH2S
Sampling methodDiffusion
Range (optional)
0-50ppm, 0-10ppm, 0-200ppm
Resolution
0.1ppm
Response time≤10S
PrincipleElectrochemical principle
Alarm modeSound, light, vibration alarm, high and low alarm values can be set by yourself
Alarm typeLow alarm, high alarm, STEL, TWA, low battery
Explosion-proof gradeII 1G Ex da ia IIC T4 Ga
Protection classIP68
Working temperature-20℃~55℃
Working humidity0-95%RH (non-condensing)
Working air pressure86~106kpa
Dimensions90*60*33mm (length*width*thickness)
WeightWeight 125g

Note 1:

  • If you require an XX gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

Features

  • Rugged and Secure Design: H2S monitor is built to withstand challenging environments, with an IP68 protection rating that makes it splash-proof, dust-proof, explosion-proof, and shock-proof. Its intrinsically safe circuit design enhances safety in hazardous locations.
  • Customizable Alarm Settings: Throughout the device's lifespan, users have the flexibility to set alarm thresholds according to their specific needs. These settings include high point alarm, low point alarm, TWA, and STEL.
  • Enhanced Safety Features: H2S monitor features an automatic self-test function that continuously verifies its operational status, enhancing safety by providing ongoing self-assessment and reliability in safety-critical situations.
  • Exceptional Battery Life: With remarkably low power consumption, this detector offers a prolonged standby time of up to 2 years, eliminating the need for battery replacement.
  • Maintenance-Free Operation: H2S detector operates continuously without the need for calibration, sensor replacements, or battery charging, ensuring a hassle-free user experience.
  • User-Friendly and Portable: Designed with user-friendliness in mind, the device is compact and lightweight. It features an intuitive two-button operation that minimizes the need for extensive training.
  • Robust Alarm System: The device's alarm system includes an ultra-loud buzzer, two bright red LEDs for both upper and lower alarms, and a combination of sound, light, and vibration alerts. These features ensure that workers are quickly and effectively alerted to potential hazards.
  • Cost-Effective Solution: This detector is not only affordable but also offers a low total cost of ownership, making it a financially prudent choice.
  • Excellent Portability: With its small size and lightweight build, the device is highly portable, allowing for easy transport and deployment.
  • Durability: Crafted from high-strength materials, the device is designed to withstand harsh environmental conditions while ensuring user comfort and longevity.

Structure

Mini portable oxygen gas detector structureApplications

Hydrogen sulfide application

Tips: Why is H2S monitor important?

  1. Safety of Personnel: H2S is a highly toxic gas. Even at low concentrations, exposure to H2S can lead to various health problems, ranging from eye and respiratory irritation to more severe effects, such as nausea, dizziness, and in extreme cases, unconsciousness or even death. By monitoring H2S levels, you can ensure the safety of workers and prevent them from being exposed to hazardous concentrations.

  2. Legal and Regulatory Compliance: Many industries are subject to strict regulations regarding H2S exposure limits. Regulatory bodies set permissible exposure limits (PELs) to protect workers and the environment. Monitoring H2S is essential to maintain compliance with these regulations, helping to avoid legal consequences and fines for non-compliance.

  3. Emergency Response and Evacuation: In cases of sudden gas releases, such as leaks or chemical spills, an H2S monitor provides early detection, allowing for swift emergency responses. Evacuations and other safety measures can be initiated promptly, potentially preventing accidents or injuries.
  4. Health Surveillance: Regular monitoring provides data that can be used for health surveillance programs. It helps in tracking the long-term effects of H2S exposure on workers, enabling early intervention and health management.
  5. Confined Space Entry: In confined space work, where H2S can accumulate and pose immediate threats, monitoring is a fundamental safety practice. It allows personnel to confirm that conditions are safe for entry and to continuously assess the environment during work.
Product reviews
The H2S monitor for oilfield work
5
Elowen
Avatar
9/2/2025 12:30 AM
Great little safety tool!  I use the H2S monitor for oilfield work, and it's been reliable every day.  Simple two-button operation makes it easy, even with gloves on.  I really like that it automatically checks itself and has such a loud alarm system.  It feels durable but isn't bulky, so I don't mind carrying it all shift.  For the price, it's definitely worth it.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

Handheld Ammonia (NH3) Gas Detector, 0 to 50/100/500 ppm

GD200-NH3
$828.16
Low price handheld pumping-type gas detector provides the Ammonia (NH3) gas leak monitoring with high accuracy sensor, audible and visual alarm, optional measuring range 0 to 50ppm, 0 to 100ppm, 0 to 200ppm, 0 to 500ppm etc., LCD display, easy readout, small & portable design, convenient to carry.