High performance portable gas detector has humanized operation functions such as one-key security detection, one-key storage, automatic image flipping, as well as the man down alarm function. The compact design makes it easy carrying.
Functions
- The portable gas detector can effectively resist a three-meter drop, has passed the EMC anti-static interference test and can work normally in the walkie-talkie environment.
- Password protection function prevents non-operators from modifying menu parameters. With safety reminder function, sound and light vibration alarm function, let operators work without worries. The high and low alarm latched function allows the operator to better capture the sudden change of the gas concentration value.
- Real-time value, TWA, STEL, MAX, MIN multiple numerical display, and the screen can be automatically turned 180 degrees, which is convenient for viewing in special operating environments.
- Built-in powerful sampling pump, fast detection speed. It can be connected 20m sampling tube externally, which is convenient for long-distance or confined space detection.
- Pump suction and diffusion dual use, to provide operators with more reliable protection. With a water trap filter, it can effectively filter water, oil, dust and other impurities. It can also be used in harsh industrial environments such as coal mines and petroleum fields.
- Beautiful and friendly user interface, reasonable and easy-to-use interactive mode. Standard storage function, one-click data export, convenient for users to analyze.
- Unique modifiable ID identification function, convenient for users to allocate and manage the instrument. A full range of automatic detection functions, automatic prompts for voltage, pump failure alarms, etc., more comfortable to use.
- One-key open storage, automatic image flip. It supports each channel sensor to restore the factory setting separately and multi-language including English, Chinese and etc.
Specification
| Model | GD400-4GAS |
| Sampling Method | Pump suction & diffusion dual-use type |
| Gas Type | CO, H2S, O2, LEL |
| Principle | Catalytic combustion (LEL), Electrochemistry (CO, H2S, O2) |
| Measuring Range | CO: 0-500/1000/2000ppm, H2S: 0-100/200/500ppm, O2: 0-25% VOL/0-30% VOL, EX/LEL: 0-100% LEL |
| Resolution | CO: 1ppm, H2S: 0.1ppm, O2: 0.1% VOL, EX/LEL: 1% LEL |
| Response Time | ≤30 seconds |
| Precision | ≤±2%F.S except for special gases |
| Language | Chinese/English (More languages can be customized) |
| Automatically Test and Calibrate After Power-on | Including reset, maximum value (MAX), minimum value (MIN), STEL, TWA value |
| Unit | PPM and mg/m3 can be switched and displayed by one key, and the concentration value is automatically converted by the system. |
| Display | Monochrome graphics (160 x 96), screen can be automatically flipped. |
| Backlight | The backlight time can be manually set and will be turned on automatically when an alarm is issued. |
| Data Record | Can store 100,000 sets of data, the storage interval is adjustable from 5 to 3600 seconds, data can be exported, with a data cable |
| Alarm | 95dB buzzer (@30cm), vibration alarm and flashing red LED and alarm status indication on the screen, alarm latched; diagnostic alarm and battery undervoltage alarm, pump block alarm; man down alarm, with early warning and optional real-time remote Bluetooth notification function |
| Battery | 3.7V rechargeable lithium battery, battery capacity 2200mA |
| Working Hours | More than 15 hours in continuous pumping mode |
| Charger | Travel charger with DC interface, charging time ≥ 4 hours |
| Explosion-proof Grade | II 1G Ex da ia IIC T4 Ga |
| Certification (EU Regulations) | CE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014) |
| Protection Grade | IP67 |
| Working Temperature | -20℃~+50℃ |
| Humidity | 0~90%RH (no condensation) |
| Environmental Pressure | 86~106Kpa |
| Size | 157*84.5*59.5mm (including the back clip/water trap filter) (length*width*height) |
| Weight | 365g (including battery, belt clip and filter) |
| Extension Probe | About 480mm (Total Length), About 300mm (Probe Head) |
| Package Included | 1 piece gas detector, 1 piece 12V/1A DC power adapter, 1 piece USB cable, 1 piece user manual, 1 piece warranty card, 1 piece filter, 1 piece aluminum suitcase |
Note 1:
If you require a gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.
- We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.
Note 2:
Regarding the flow rate for gas detectors, there are 2 types:
- Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
- Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)
If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.
Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.
Details

Applications

Tips for using explosion-proof multi gas detector
- Pay attention to the measuring range of the portable gas detector used:
Any gas detector has a fixed detection range, and the measurement can only be completed within this range, otherwise the measured result is much lower than the value of your environment. In addition, measuring over the range for a long time will cause damage to the sensor, so that the correct result cannot be obtained in the measurement range later. - Pay attention to the service life of the sensor in the gas detector used:
Gas detectors have a limited service life, and portable gas detectors are no exception. Even if they are not used frequently, they will still experience aging. In general, among the portable gas detectors, the photoionization detector has the longest lifespan of about four years; the lifespan of the LEL sensor is the second, which can be used for more than three years; the lifespan of the electrochemical specific gas sensor is relatively short, Generally within one to two years; the oxygen sensor can only be used for about one year.
Therefore, be sure to read the instruction carefully before use, and use it within the validity period of the sensor. If it is found to be expired, it needs to be replaced immediately.
The detector needs to be calibrated and tested frequently.
Portable gas detectors generally adopt a relative comparison method for measurement, and the measurement method is as follows:
- First calibrate the instrument with a standard concentration of gas and a zero gas, and obtain the standard curve and store it in the instrument;
- Compare the electrical signal of the standard concentration with the electrical signal generated by the concentration of the gas to be measured, and obtain an accurate gas concentration value after calculation.
I'm contacting you to enquire about <explosion-proof multi gas detector>.
I'm interested in your product and I want to use it to measure O2 in the air. So I have questions about your product.
1) Is this machine high precision? It's said that there is about 21% O2 in the air, so I wonder whether this machine can measure by after the decimal point.
2)Were there any people who bought it to measure the O2 in the air? If you know about that or thesis, please tell me about that.
Can the first item control another item such as a pump, etc.
Can you give me some more details of item 11 on your list 10m tube ?