Selling a highly accurate fluoride sensor for water quality with a measurement range from 0 to saturation, 0.01 ppm resolution. The water quality sensor has real-time online monitoring and automatic temperature compensation function. Application for drinking water, wastewater, air quality, chemicals, seawater, soil, food, biological fluids.
SKU: ATO-WQS-IF
Free Shipping
Delivery date: 6-12 days

Highly accurate fluoride sensor with a 0 to saturation range and 0.01 ppm resolution. It supports real-time monitoring and automatic temperature compensation, perfect for drinking water, wastewater, air quality, chemicals.

Specification

Ion Concentration
Measurement Range0~Saturation
Resolution0.01 ppm
Measurement Accuracy±3% FS
Temperature
Measurement Range-10℃~110℃
Resolution0.1 ℃
Measurement Accuracy±0.5 ℃
Temperature TypeThermistor NTC10K
Temperature CompensationAutomatic
Data Transmission
InterfaceRS-485
ProtocolMODBUS-RTU communication protocol
Other Parameters
Working Voltage9~27 VDC
Dielectric Strength2500 Vrms
Power ConsumptionApprox. 0.5 W
MaterialPPS Solid
Installation Method3/4 inch front and rear thread
Slope57 ± 2 mV
Sensitivity± 2%
Ion SelectivityTrivalent metal ions (e.g., Al³⁺, Fe³⁺, Cr³⁺)
Working Temperature Range0~80℃
Pressure Range0~2 atm
Response Time30 seconds to 95% response
StorageLong-term: dry storage, short-term: store in standard electrolyte solution
pH Range5~8 pH
Internal Resistance20~50 MΩ
MaintenanceRinse with distilled water, use standard electrolyte solution
Online MonitoringSupported
Reference Electrode20 ppm Fluoride
ConnectorEnd terminal
ApplicationsDrinking water, wastewater, air quality, chemicals, seawater, soil, food, biological fluids, testing for fluoride


Feature

Ionised water quality sensor features

  • Low Power Consumption: Consuming less than 0.5W, the fluoride sensor is designed to be energy-efficient and cost-effective for long-term use.
  • High Precision Electrodes: Equipped with high-precision ion-selective electrodes, the sensor ensures accurate and stable measurements without the need for trial reagents.
  • RS485 Output: It offers RS485 output, enabling seamless integration with monitoring systems for continuous, real-time data tracking.
  • Automatic Temperature Compensation: The water quality sensor automatically compensates for temperature changes, maintaining reliable and consistent readings.
  • Durability and Environmental Resistance: Designed to withstand external environmental factors, this sensor is suitable for use in both industrial and natural settings.
  • Easy Installation: With a G3/4 pipe thread, easy to install, reducing both setup time and cost.
  • High-Quality Cable: It comes with a 5m (customizable) low-noise cable, ensuring stable and interference-free data transmission.

Dimension (Unit: mm)

Ionised water quality sensor size

Wiring Instructions

FunctionColorDescription
Data TransmissionYellow WireRS-485 Communication T/R+ (A)
White WireRS-485 Communication T/R− (B)
Power SupplyRed WireDC Power Positive
Black WireDC Power Ground


Application

Ionised water quality sensor application

Tips: How does the fluoride sensor work?

The fluoride sensor works by using an ion-selective electrode (ISE) that specifically responds to fluoride ions in the water. When fluoride ions come into contact with the electrode, they generate a voltage that is directly proportional to their concentration in the water. The sensor measures this voltage and converts it into a corresponding fluoride concentration, providing accurate and real-time data.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Highly accurate fluoride sensor with a 0 to saturation range and 0.01 ppm resolution. It supports real-time monitoring and automatic temperature compensation, perfect for drinking water, wastewater, air quality, chemicals.

Specification

Ion Concentration
Measurement Range0~Saturation
Resolution0.01 ppm
Measurement Accuracy±3% FS
Temperature
Measurement Range-10℃~110℃
Resolution0.1 ℃
Measurement Accuracy±0.5 ℃
Temperature TypeThermistor NTC10K
Temperature CompensationAutomatic
Data Transmission
InterfaceRS-485
ProtocolMODBUS-RTU communication protocol
Other Parameters
Working Voltage9~27 VDC
Dielectric Strength2500 Vrms
Power ConsumptionApprox. 0.5 W
MaterialPPS Solid
Installation Method3/4 inch front and rear thread
Slope57 ± 2 mV
Sensitivity± 2%
Ion SelectivityTrivalent metal ions (e.g., Al³⁺, Fe³⁺, Cr³⁺)
Working Temperature Range0~80℃
Pressure Range0~2 atm
Response Time30 seconds to 95% response
StorageLong-term: dry storage, short-term: store in standard electrolyte solution
pH Range5~8 pH
Internal Resistance20~50 MΩ
MaintenanceRinse with distilled water, use standard electrolyte solution
Online MonitoringSupported
Reference Electrode20 ppm Fluoride
ConnectorEnd terminal
ApplicationsDrinking water, wastewater, air quality, chemicals, seawater, soil, food, biological fluids, testing for fluoride


Feature

Ionised water quality sensor features

  • Low Power Consumption: Consuming less than 0.5W, the fluoride sensor is designed to be energy-efficient and cost-effective for long-term use.
  • High Precision Electrodes: Equipped with high-precision ion-selective electrodes, the sensor ensures accurate and stable measurements without the need for trial reagents.
  • RS485 Output: It offers RS485 output, enabling seamless integration with monitoring systems for continuous, real-time data tracking.
  • Automatic Temperature Compensation: The water quality sensor automatically compensates for temperature changes, maintaining reliable and consistent readings.
  • Durability and Environmental Resistance: Designed to withstand external environmental factors, this sensor is suitable for use in both industrial and natural settings.
  • Easy Installation: With a G3/4 pipe thread, easy to install, reducing both setup time and cost.
  • High-Quality Cable: It comes with a 5m (customizable) low-noise cable, ensuring stable and interference-free data transmission.

Dimension (Unit: mm)

Ionised water quality sensor size

Wiring Instructions

FunctionColorDescription
Data TransmissionYellow WireRS-485 Communication T/R+ (A)
White WireRS-485 Communication T/R− (B)
Power SupplyRed WireDC Power Positive
Black WireDC Power Ground


Application

Ionised water quality sensor application

Tips: How does the fluoride sensor work?

The fluoride sensor works by using an ion-selective electrode (ISE) that specifically responds to fluoride ions in the water. When fluoride ions come into contact with the electrode, they generate a voltage that is directly proportional to their concentration in the water. The sensor measures this voltage and converts it into a corresponding fluoride concentration, providing accurate and real-time data.

Only registered users can write reviews