Flat Load Cell, Diaphragm Type, 50kg/300kg/1 ton to 10 ton

$142.69
Favorable flat load cell with diaphragm type all-in-one design, large force area, available in a variety of ranges from 50kg/300kg/1 ton/2ton to 10 ton, stable and reliable performance, suitable for all kinds of industrial automation measurement and control systems for force measurement and weighing.
SKU: ATO-LC-102
*
*
*
Free Shipping
Delivery date: 6-12 days

After purchasing one ATO load cell, you can buy a special digital panel meter to obtain readings directly, or buy a transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4-20mA.

Note: The load cell cannot be connected to both the transmitter and the controller at the same time — only one can be selected.

Designed for high performance weighing systems, the flat load cells are offered in ranges from 50kg/100kg/200kg/300kg/500kg/1ton/2ton to 10 tons. The unique design of the load cell has a zero drift and creep error of only 0.1% F.S.. The load cell material is made of high quality alloy steel, together with Φ5*2m tensile cable design, to ensure the long term durability and easy installation of the load cell.

Specification

ModelATO-DYMH-102
Capacity Rang0-50kg/100kg/200kg/300kg/500kg/1 ton/2 ton/3 ton/5 ton/10 ton (optional)
Matched TransmitterATO-LCTR-OA (Click it to the transmitter page)
Matched Display ControllerATO-DPM-DY800 (Click it to the controller page)
Rated Output1.0-2.0±0.05mV/V
Zero Balance±2%F.S.
Non-Linearity0.5%F.S.
Hysteresis0.1%F.S.
Repeatability0.1%F.S.
Creep0.1%F.S. (30min)
Temp Effect on Output0.05%F.S./10°C
Temp Effect on Zero0.05%F.S./10°C
Response frequency10kHz
MaterialAlloy steel
Impedance700Ω
Insulation≥5000MΩ/100VDC
Working Voltage5-15V
Operating Temp Range-20°C~80°C
Safe Overload1.5
Maximum Overload2
Cable SpecificationsΦ5*2m
Cable Ultimate Pull10kg


Dimension (unit: mm)

Flat load celll size

Details

Flat load cell detail

  1. High-quality Alloy Steel: 42CrMo high-strength alloy steel with good hardenability and strong resistance to mechanical fatigue.
  2. Precision Waterproof Connector: 6 angle waterproof connector with spring buffer to prevent wire pulling and breaking.
  3. Industrial High Precision Strain Gauge: Small thermal hysteresis, good heat resistance, small creep, good stability in long-term use.
  4. Planar Structure: The load cell provides a variety of sizes and ranges for selection, with a wide range of applications and high measuring accuracy and good shock resistance.

Load Cell Force Diagram

Flat load cell force diagram

Wiring Drawing

Flat load cell wiring drawing

Note: This is the pressure wiring of the load cell, such as the measurement of tensile force need to be the definition of the green wire and white wire wiring alignment.

Tips: What is a flat load cell?

Flat load cells are compact force measuring devices designed to measure compressive forces or weights. Its flat shape is suitable for installation in places where space is limited. Due to their high accuracy and sensitivity, flat load cells are often used in industrial equipment, automated production lines, test instruments and medical devices.

When installing a flat load cell, make sure its bottom and contact surface are flat and clean to avoid measurement error. The load cell needs to be fixed to the mounting surface by means of screws or adhesives, depending on the application environment. When connecting, use the special signal cable provided by the manufacturer and wire correctly according to the equipment instructions. In addition, avoid applying excessive lateral forces or impacts on the sensor housing to prolong the service life.

In this video, we've shown you how to calibrate the weight transmitter Model 610 by ATO using a compression load cell so that you can make sure you get the most accurate readings possible in your measurement.

In this video, ATO offers a variety of load cells and weigh modules designed for your applications.

Product reviews
Good Quality of Flat Load Cell, Diaphragm Type, 50kg/300kg/1 ton to 10 ton
5
Young
Avatar
1/13/2025 6:46 PM
I am satisfied with this Flat Load Cell, The performance and quality of Diaphragm Type! This sensor offers multiple range options from 50kg to 10 tons, which can be flexibly applied in various scenarios. I used 1-ton and 5-ton models in mechanical force measuring equipment, and the measurement results were accurate and stable. The shell is made of high-quality stainless steel material, which is corrosion-resistant and suitable for various harsh working environments.
Was this review helpful? Yes No (0/0)
Recommendations load cell
5
Paffan
Avatar
5/21/2025 8:12 PM
We need a piezoelectric load cell for impact testing. We would like a load cell with a range of at least 5000 lbf to 10000 lbf and fast data acquisition. Please give me some recommendations.
Was this review helpful? Yes No (0/0)
ATO Responded
1. When performing a drop test, the sensor usually needs to be amplified by 2 times. So if your load is 10,000 lbf, I would recommend a 10 ton range and pair it with this flat film load cell. Part number: ATO-LC-102, range 0-10 tons. 2. We recommend this handheld digital panel meter for load cells, part number: ATO-DPM-920H, which can capture impact forces.
Angle of Use
5
Jurgis
Avatar
9/2/2025 8:40 PM
Does the sensor require the load to be perfectly vertical for proper operation? Is it acceptable if the load is at an angle from true vertical (e.g., approximately 30 degrees)?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the DYMH-102 unit must be perfectly vertical for the sensor to function properly. If it is tilted 30 degrees and subjected to force, the forces will be unbalanced, potentially damaging the sensor and resulting in inaccurate readings.
Scope of application
4
Remiel
Avatar
7/29/2026 12:18 AM
Hello, I would like to know if the "flat-plate load cell" is suitable for Hot Air AC (TVAC) conditions?
Was this review helpful? Yes No (0/0)
ATO Responded
Please tell us what the vacuum pressure and ambient operating temperature range are for these TVAC conditions?
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

After purchasing one ATO load cell, you can buy a special digital panel meter to obtain readings directly, or buy a transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4-20mA.

Note: The load cell cannot be connected to both the transmitter and the controller at the same time — only one can be selected.

Designed for high performance weighing systems, the flat load cells are offered in ranges from 50kg/100kg/200kg/300kg/500kg/1ton/2ton to 10 tons. The unique design of the load cell has a zero drift and creep error of only 0.1% F.S.. The load cell material is made of high quality alloy steel, together with Φ5*2m tensile cable design, to ensure the long term durability and easy installation of the load cell.

Specification

ModelATO-DYMH-102
Capacity Rang0-50kg/100kg/200kg/300kg/500kg/1 ton/2 ton/3 ton/5 ton/10 ton (optional)
Matched TransmitterATO-LCTR-OA (Click it to the transmitter page)
Matched Display ControllerATO-DPM-DY800 (Click it to the controller page)
Rated Output1.0-2.0±0.05mV/V
Zero Balance±2%F.S.
Non-Linearity0.5%F.S.
Hysteresis0.1%F.S.
Repeatability0.1%F.S.
Creep0.1%F.S. (30min)
Temp Effect on Output0.05%F.S./10°C
Temp Effect on Zero0.05%F.S./10°C
Response frequency10kHz
MaterialAlloy steel
Impedance700Ω
Insulation≥5000MΩ/100VDC
Working Voltage5-15V
Operating Temp Range-20°C~80°C
Safe Overload1.5
Maximum Overload2
Cable SpecificationsΦ5*2m
Cable Ultimate Pull10kg


Dimension (unit: mm)

Flat load celll size

Details

Flat load cell detail

  1. High-quality Alloy Steel: 42CrMo high-strength alloy steel with good hardenability and strong resistance to mechanical fatigue.
  2. Precision Waterproof Connector: 6 angle waterproof connector with spring buffer to prevent wire pulling and breaking.
  3. Industrial High Precision Strain Gauge: Small thermal hysteresis, good heat resistance, small creep, good stability in long-term use.
  4. Planar Structure: The load cell provides a variety of sizes and ranges for selection, with a wide range of applications and high measuring accuracy and good shock resistance.

Load Cell Force Diagram

Flat load cell force diagram

Wiring Drawing

Flat load cell wiring drawing

Note: This is the pressure wiring of the load cell, such as the measurement of tensile force need to be the definition of the green wire and white wire wiring alignment.

Tips: What is a flat load cell?

Flat load cells are compact force measuring devices designed to measure compressive forces or weights. Its flat shape is suitable for installation in places where space is limited. Due to their high accuracy and sensitivity, flat load cells are often used in industrial equipment, automated production lines, test instruments and medical devices.

When installing a flat load cell, make sure its bottom and contact surface are flat and clean to avoid measurement error. The load cell needs to be fixed to the mounting surface by means of screws or adhesives, depending on the application environment. When connecting, use the special signal cable provided by the manufacturer and wire correctly according to the equipment instructions. In addition, avoid applying excessive lateral forces or impacts on the sensor housing to prolong the service life.

Product reviews
Good Quality of Flat Load Cell, Diaphragm Type, 50kg/300kg/1 ton to 10 ton
5
Young
Avatar
1/13/2025 6:46 PM
I am satisfied with this Flat Load Cell, The performance and quality of Diaphragm Type! This sensor offers multiple range options from 50kg to 10 tons, which can be flexibly applied in various scenarios. I used 1-ton and 5-ton models in mechanical force measuring equipment, and the measurement results were accurate and stable. The shell is made of high-quality stainless steel material, which is corrosion-resistant and suitable for various harsh working environments.
Was this review helpful? Yes No (0/0)
Recommendations load cell
5
Paffan
Avatar
5/21/2025 8:12 PM
We need a piezoelectric load cell for impact testing. We would like a load cell with a range of at least 5000 lbf to 10000 lbf and fast data acquisition. Please give me some recommendations.
Was this review helpful? Yes No (0/0)
ATO Responded
1. When performing a drop test, the sensor usually needs to be amplified by 2 times. So if your load is 10,000 lbf, I would recommend a 10 ton range and pair it with this flat film load cell. Part number: ATO-LC-102, range 0-10 tons. 2. We recommend this handheld digital panel meter for load cells, part number: ATO-DPM-920H, which can capture impact forces.
Angle of Use
5
Jurgis
Avatar
9/2/2025 8:40 PM
Does the sensor require the load to be perfectly vertical for proper operation? Is it acceptable if the load is at an angle from true vertical (e.g., approximately 30 degrees)?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the DYMH-102 unit must be perfectly vertical for the sensor to function properly. If it is tilted 30 degrees and subjected to force, the forces will be unbalanced, potentially damaging the sensor and resulting in inaccurate readings.
Scope of application
4
Remiel
Avatar
7/29/2026 12:18 AM
Hello, I would like to know if the "flat-plate load cell" is suitable for Hot Air AC (TVAC) conditions?
Was this review helpful? Yes No (0/0)
ATO Responded
Please tell us what the vacuum pressure and ambient operating temperature range are for these TVAC conditions?
Only registered users can write reviews
Customers who bought this item also bought

Compression Load Cell, 300kg/500kg/2 ton/10 ton/15 ton to 30 ton

ATO-LC-TC03
$157.78
Compression load cell is special designed for weight measurement, with compact structure, pouring sealant or welding seal, low height, all stainless steel, good anti-eccentric load performance and corrosion-resistant. Load cell can be applied for platform scale, truck scale, rail weighbridge and automated measurement and control areas.

Digital Load Cell Amplifier, Output 4-20mA/0-10V/RS485

ATO-LCTR-OAR
$109.85
High precision load cell amplifier has a 6 digit LED display, output signal 4-20mA/ 0-5V/ 0-10V/ RS485. There are 3 keys for parameter settings. Digital load cell amplifier can be calibrated on-line by its 3 keys. The setting parameters include zero, capacity, communication rate, division value, decimal digits, etc.