Compression Load Cell, 300kg/500kg/2 ton/10 ton/15 ton to 30 ton

$157.78
Compression load cell is special designed for weight measurement, with compact structure, pouring sealant or welding seal, low height, all stainless steel, good anti-eccentric load performance and corrosion-resistant. Load cell can be applied for platform scale, truck scale, rail weighbridge and automated measurement and control areas.
SKU: ATO-LC-TC03
*
Free Shipping
Delivery date: 6-12 days

After purchasing one ATO load cell, you can buy a special digital panel meter to obtain readings directly, or buy a transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4-20mA.

Note: The load cell cannot be connected to both the transmitter and the controller at the same time — only one can be selected.

Compression load cells have capacity range from 300kg, 500kg, 1000kg, 10 ton, 15 ton to 30 ton. Load cell capacity can be customized according to customer requirements.

The compression button load cell is a high-precision measuring device mainly used to measure small weight or pressure changes. The low profile and compact design make it ideal for use in tight spaces, and the all-stainless steel construction provides corrosion resistance and reliability in harsh industrial environments. Unique button design ensures accurate load distribution.

Specification

ModelATO-LCC-TJH-14
Shipping Weight1.3~6.3kg
Capacity Range *300 kg~30 ton
Matched Display ControllerATO-TY5DA3 (Click it to the controller page)
Matched TransmitterATO-LCTR-NTB3K (Click it to the transmitter page)
Accuracy0.03%F.S (linearity + hysteresis + repeatability)
Sensitivity2.0±0.1mV/V
Creep±0.03~±0.05%F.S/30min
Zero Output±1%F.S
Temperature Effect on Zero±0.03%F.S/10℃
Temperature Effect on Output±0.03%F.S/10℃
Operating Temperature-20℃~+65℃
Input Impedance380±10Ω, 750±15Ω
Output Impedance350±3Ω, 700±5Ω
Insulation Resistance≥5000MΩ
Safety Overload150%F.S
Bridge Voltage (excitation voltage)DC 10V
MaterialStainless steel
Protection ClassIP67
Cable length3m (<5 ton), 6m (≥5 ton)
WiringEXC+: Red, EXC-: Black, SIG+: Green, SIG-: White


Feature

Compression load cell 200kg to 30 ton feature

  • High-Quality Stainless Steel Construction: Made from durable stainless steel, ensuring strength and resistance to wear and tear in demanding environments.
  • Strong Anti-Corrosion Ability: The product is designed to withstand harsh conditions with superior resistance to corrosion, making it suitable for various industrial and outdoor applications.
  • Dual Seals for Protection: Equipped with double seals for enhanced protection against dust, moisture, and contaminants, ensuring longevity and reliable performance.
  • Versatile Force Measurement: Ideal for a wide range of force measurement applications, including industrial weighing systems, automotive platforms, and conveyor systems.
  • Suitable for Harsh Environments: Engineered to perform accurately in challenging environments, making it perfect for use in factories, construction sites, and other harsh conditions.
  • Applications in Automation and Control Systems: Commonly used in automotive, rail, and automation control systems, ensuring precise and accurate force monitoring for operational efficiency.

Dimension

CapacityDimension (mm)
ΦAΦBΦCHEMSR
300~1000kg7864154032M640
2~10 ton8266224432M850
15~30 ton12790257062M1060

Compression load cell 200kg to 30 ton dimension

Wiring Method

Load cell wiring method

Application

Compression load cell 200kg to 30 ton application

Tips: What factors can affect the performance of a Compression Load Cell?

Several factors can impact the performance of a Compression Load Cell:

  • Temperature Variations: Extreme temperature fluctuations can cause measurement inaccuracies due to changes in the load cell’s material properties. Many compression load cells are designed with temperature compensation to mitigate this issue, but temperatures outside the specified operating range may still affect accuracy.
  • Improper Alignment: If the load cell is not correctly aligned with the applied load (i.e., if it experiences side loading or bending), it can lead to inaccurate readings or even damage to the cell.
  • Overloading: Exceeding the rated capacity of the load cell can cause permanent damage and affect the accuracy of measurements. Regular calibration and careful attention to the maximum rated load are necessary to avoid overloading.
  • Vibration and Shock: Mechanical shock or vibrations from surrounding machinery can impact the accuracy of measurements. It's important to install the load cell in an environment where vibrations and shock are minimized, or use damping materials to absorb impacts.
  • Electrical Interference: External electrical sources, such as motors or other machinery, can generate electromagnetic interference (EMI) that affects the signal output. Using proper shielding and grounding techniques can minimize this issue.

How to Choose the Right Load Cell

Load cells are sensors used to measure the weight of an object. Their working principle is based on physical phenomena such as elastic deformation, electromagnetic force and pressure change, with high accuracy and reliability. These sensors can accurately measure the weight of an object for monitoring, control and recording. This video will help you choose the right load cell through six factors: Application, operating environment, material type and sealing technology, capacity/resolution requirements and output signal type.

In this video, we've shown you how to calibrate the weight transmitter Model 610 by ATO using a compression load cell so that you can make sure you get the most accurate readings possible in your measurement.

Product reviews
Will the compression load cell be calibrated before shipment?
5
Metcalf
Avatar
5/7/2021 2:01 AM
If I order the load cell and the digital controller, would the equipment be ready to operate when received? I am aware that it need to be calibrated.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the load cell and digital controller will be well calibrated before shipping out, so you can use once received.
Specification of load cell
5
Supur
Avatar
9/16/2021 8:10 PM
Looking for a disc type compressive load cell capable of a max load of ~300kg. What outputs do your load cells have? What is the resolution/accuracy?
Was this review helpful? Yes No (0/0)
ATO Responded
The output of our load cell is 0-20mV.
After purchasing our ATO load cell, you can buy our special digital panel meter to obtain readings directly, or buy our transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4 -20mA.
ATO-LC-TC03
5
Wade
Avatar
11/12/2021 8:53 AM
I would like to purchase 10 of these.   Which readout would you recommend for use with this?
Was this review helpful? Yes No (0/0)
ATO Responded
We know the range of the load cell you need, so we can recommend the load cell that suits you.
Can you tailor your load cell to our requirements?
5
Lindsay
Avatar
12/28/2021 11:23 PM
Can you tailor your load cell to our requirements?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can. Just tell us required specs/dims.
Any additional charges for the 0-5V Customized output signal?
5
Daniel
Avatar
1/6/2023 12:26 PM
Hi I would like to know if there's any additional charges for all the variants from 300KG to 30 Ton with 0-5V output signal. Thank you!
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you need to buy an additional transmitter (ATO-LCTR-OA). Please go to the page https://www.ato.com/load-cell-transmitter-output-0-5v-4-20ma.
High accuracy load cell
5
kerri
Avatar
2/5/2023 6:48 PM
"The 300kg load cell and its reader well received today , According to the manual calibration instruction, I quickly adjust the load cell and it works as description that high accuracy. Highly recommend this product.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

After purchasing one ATO load cell, you can buy a special digital panel meter to obtain readings directly, or buy a transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4-20mA.

Note: The load cell cannot be connected to both the transmitter and the controller at the same time — only one can be selected.

Compression load cells have capacity range from 300kg, 500kg, 1000kg, 10 ton, 15 ton to 30 ton. Load cell capacity can be customized according to customer requirements.

The compression button load cell is a high-precision measuring device mainly used to measure small weight or pressure changes. The low profile and compact design make it ideal for use in tight spaces, and the all-stainless steel construction provides corrosion resistance and reliability in harsh industrial environments. Unique button design ensures accurate load distribution.

Specification

ModelATO-LCC-TJH-14
Shipping Weight1.3~6.3kg
Capacity Range *300 kg~30 ton
Matched Display ControllerATO-TY5DA3 (Click it to the controller page)
Matched TransmitterATO-LCTR-NTB3K (Click it to the transmitter page)
Accuracy0.03%F.S (linearity + hysteresis + repeatability)
Sensitivity2.0±0.1mV/V
Creep±0.03~±0.05%F.S/30min
Zero Output±1%F.S
Temperature Effect on Zero±0.03%F.S/10℃
Temperature Effect on Output±0.03%F.S/10℃
Operating Temperature-20℃~+65℃
Input Impedance380±10Ω, 750±15Ω
Output Impedance350±3Ω, 700±5Ω
Insulation Resistance≥5000MΩ
Safety Overload150%F.S
Bridge Voltage (excitation voltage)DC 10V
MaterialStainless steel
Protection ClassIP67
Cable length3m (<5 ton), 6m (≥5 ton)
WiringEXC+: Red, EXC-: Black, SIG+: Green, SIG-: White


Feature

Compression load cell 200kg to 30 ton feature

  • High-Quality Stainless Steel Construction: Made from durable stainless steel, ensuring strength and resistance to wear and tear in demanding environments.
  • Strong Anti-Corrosion Ability: The product is designed to withstand harsh conditions with superior resistance to corrosion, making it suitable for various industrial and outdoor applications.
  • Dual Seals for Protection: Equipped with double seals for enhanced protection against dust, moisture, and contaminants, ensuring longevity and reliable performance.
  • Versatile Force Measurement: Ideal for a wide range of force measurement applications, including industrial weighing systems, automotive platforms, and conveyor systems.
  • Suitable for Harsh Environments: Engineered to perform accurately in challenging environments, making it perfect for use in factories, construction sites, and other harsh conditions.
  • Applications in Automation and Control Systems: Commonly used in automotive, rail, and automation control systems, ensuring precise and accurate force monitoring for operational efficiency.

Dimension

CapacityDimension (mm)
ΦAΦBΦCHEMSR
300~1000kg7864154032M640
2~10 ton8266224432M850
15~30 ton12790257062M1060

Compression load cell 200kg to 30 ton dimension

Wiring Method

Load cell wiring method

Application

Compression load cell 200kg to 30 ton application

Tips: What factors can affect the performance of a Compression Load Cell?

Several factors can impact the performance of a Compression Load Cell:

  • Temperature Variations: Extreme temperature fluctuations can cause measurement inaccuracies due to changes in the load cell’s material properties. Many compression load cells are designed with temperature compensation to mitigate this issue, but temperatures outside the specified operating range may still affect accuracy.
  • Improper Alignment: If the load cell is not correctly aligned with the applied load (i.e., if it experiences side loading or bending), it can lead to inaccurate readings or even damage to the cell.
  • Overloading: Exceeding the rated capacity of the load cell can cause permanent damage and affect the accuracy of measurements. Regular calibration and careful attention to the maximum rated load are necessary to avoid overloading.
  • Vibration and Shock: Mechanical shock or vibrations from surrounding machinery can impact the accuracy of measurements. It's important to install the load cell in an environment where vibrations and shock are minimized, or use damping materials to absorb impacts.
  • Electrical Interference: External electrical sources, such as motors or other machinery, can generate electromagnetic interference (EMI) that affects the signal output. Using proper shielding and grounding techniques can minimize this issue.
Product reviews
Will the compression load cell be calibrated before shipment?
5
Metcalf
Avatar
5/7/2021 2:01 AM
If I order the load cell and the digital controller, would the equipment be ready to operate when received? I am aware that it need to be calibrated.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the load cell and digital controller will be well calibrated before shipping out, so you can use once received.
Specification of load cell
5
Supur
Avatar
9/16/2021 8:10 PM
Looking for a disc type compressive load cell capable of a max load of ~300kg. What outputs do your load cells have? What is the resolution/accuracy?
Was this review helpful? Yes No (0/0)
ATO Responded
The output of our load cell is 0-20mV.
After purchasing our ATO load cell, you can buy our special digital panel meter to obtain readings directly, or buy our transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4 -20mA.
ATO-LC-TC03
5
Wade
Avatar
11/12/2021 8:53 AM
I would like to purchase 10 of these.   Which readout would you recommend for use with this?
Was this review helpful? Yes No (0/0)
ATO Responded
We know the range of the load cell you need, so we can recommend the load cell that suits you.
Can you tailor your load cell to our requirements?
5
Lindsay
Avatar
12/28/2021 11:23 PM
Can you tailor your load cell to our requirements?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can. Just tell us required specs/dims.
Any additional charges for the 0-5V Customized output signal?
5
Daniel
Avatar
1/6/2023 12:26 PM
Hi I would like to know if there's any additional charges for all the variants from 300KG to 30 Ton with 0-5V output signal. Thank you!
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you need to buy an additional transmitter (ATO-LCTR-OA). Please go to the page https://www.ato.com/load-cell-transmitter-output-0-5v-4-20ma.
High accuracy load cell
5
kerri
Avatar
2/5/2023 6:48 PM
"The 300kg load cell and its reader well received today , According to the manual calibration instruction, I quickly adjust the load cell and it works as description that high accuracy. Highly recommend this product.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

5 Digit Display Controller for Load Cells

ATO-DPM-LC5D
$210.80
Digital panel meter can cooperate with load cells, force sensors and weighing sensors, two outputs for data comparison, digital panel meter can display gross, net, peak and valley value alternately.

Load Cell Transmitter, Output 0-5V/0-10V/4-20mA

ATO-LCTR-OA
$81.27
Load cell transmitter is made of aluminum alloy, output standard signal 0-5V/0-10V/4-20mA, has linear compensation, humidity compensation, external zero debugging, external span debugging, input overload protection and output short circuit protection functions.

Digital Load Cell Amplifier, Output 4-20mA/0-10V/RS485

ATO-LCTR-OAR
$109.85
High precision load cell amplifier has a 6 digit LED display, output signal 4-20mA/ 0-5V/ 0-10V/ RS485. There are 3 keys for parameter settings. Digital load cell amplifier can be calibrated on-line by its 3 keys. The setting parameters include zero, capacity, communication rate, division value, decimal digits, etc.

Load Cell Junction Box for Scales, 2/3/4/6/8/10 Inlets to 1 Outlet

ATO-LCBOX-10I
$66.67
Multi-channel load cell junction box has 2/3/4/6/8/10 inlets and 1 outlet, aluminum alloy casing, good anti-interference, special for waterproof sealing joint, waterproof and dustproof rubber gasket for cover, easy to assemble and debug. Each channel can be adjusted balance to prevent damage to the sensor caused by inductive lightning and surge signals.

Strain Gauge Load Cell, S type, 5kg/50kg/1000kg/3 ton to 20 ton

ATO-LC-S01
$88.41
S type load cell can bear both tension and pressure, with good output symmetry, high accuracy, compact structure and complete specifications. Strain gauge load cell can be applied for batching scale, electronic-mechanical scale, crane scales and other force value measurement and control.