Fixed Combustible Gas Detector, 0 to 100%LEL

$526.67
Combustible gas detector is fixed to detect the flammable gas leakage and gives the alarm with sound and light. With real-time display and remote control, flammable gas detector is available with signal output 4-20mA and RS485, fast response and high accuracy.
SKU: GD300-EX
*
*
*
*
Free Shipping
Delivery date: 6-12 days

Fixed combustible gas detector is 24-hour oneline to monitor the leakage of combustible gas 0 to 100% LEL, widely applied in the confined space, gas pipeline area, gas station, material spraying workshop, chemical industry, and other flammable and explosive gas storage area.

Features

  • Adopting high precision sensor for accurate gas leak detection.
  • Equipped with 3-wire system 4-20mA and RS485 output, relay output, (optional).
  • Compatible with various controlled alarms, PLC, DCS and other control system, and can be remote monitored.
  • Explosion-proof design, fast, relaible and stable.
  • Infrared ray controller can remote control the alarm point settings, zero calibration, and address modification.
  • Two-stage alarm with sound and light, and the alarm point is settable.
  • With self-calibration function, and three standard keys will be used to realize on-site maintenance.
  • Can output one or two on-off signals, can drive ventilator, solenoid valve or other external devices.

Specification

ModelGD300-EX
Detection PrincipleCatalytic Combustion
GasCombustible Gas (EX)
Range (Optional)0 to 100% LEL
Resolution1% LEL
Calibration KitGas pressure regulator (calibration gas cylinder NOT included)
Accuracy≤±3% F.S.
Responce Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Signal Output (Optional)4-20mA and RS485
Relay output: one group of relay output (1NO+1NC, 5A/30V) for one alarm (default), or two groups of relay output (2NO+2NC, 5A/30V) for high/low alarm (optional).
AlarmsSound, light
DisplayHigh light nixie tube display
InstallationWall-mounted, piping type, flow-type (according to the detected environment)
ConnectionG1/2 is the inlet and outlet for power and signal lines
Pipe-mounted type: The installation thread size of the instrument is M45*P2.0
Operating Time24h
Explosion-proof GradeII 2G Ex db IIC T4 Gb
Protection GradeIP65
CertificationCE, ATEX
Working Voltage12~36V DC
Case MaterialDie-casting aluminum housing
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Dimension206*179*90mm
Weight≤1.6kg
Power AdapterInput 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug, AU plug or UK plug)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube


Notes

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

Dimensions (Unit: mm)

Fixed gas detector dimensions

Installation Guide

The following precautions apply when connecting the GD300 series fixed gas detector to a pipeline:

  1. Working pressure should be stable at 1 bar ±10%, and the flow rate should be controlled at 300 mL/min.
  2. Working temperature is -20°C to +50°C.
  3. Working humidity is 0–95% RH. When the humidity is above 60% RH, it is recommended to use a dehumidifier or add a filter. When the humidity is above 95% RH, the gas is essentially saturated with water, making measurement impossible.
  4. The gas detector should be installed indoors. If it is installed outdoors, a rain cover should be added to protect the entire instrument.
  5. For the second pipeline connection method of the GD300 gas detector, the pipe-mounted installation, the detector mounting thread size is M45 × P2.0. During installation, hold the detector with both hands, keeping the sensor parallel to the mounting thread. Align it with the threaded port, rotate the detector clockwise, and install it in the desired position. To prevent gas leakage at the threaded connection, an appropriate amount of thread seal tape can be wrapped around the sensor head thread before installation.

***Other Common Gases and Ranges Available for Fixed Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/10/50/100/200/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/9999ppm, 0-2/5/10/20/25/30/50/100%VOL0.1ppm/1ppm/0.001%VOL/0.01%VOL/0.1%VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Combustible Gas (EX)0-100%LEL1%LEL
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100%LEL1%LEL
Hydrogen (H2)0-10/20/500/1000/2000/5000/9999ppm, 0-2/4% VOL, 0-100% LEL0.1ppm/1ppm/0.001%VOL/1%LEL
Hydrogen Chloride (HCL)0-10/20/50/100/200ppm0.01ppm/0.1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Sulfide (H2S)0-5/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Methane (CH4)0-50/100%VOL, 0-100%LEL0.01%VOL/0.1%VOL/1%LEL
Nitric Oxide (NO)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99/0-100%VOL0.01%VOL/0.1%VOL
Nitrogen Dioxide (NO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen Oxides (NOX)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25/30/100%VOL0.01%VOL/0.1%VOL
Ozone (O3)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm

Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.

Details

Fixed Combustible Gas Detector Details

Tips: Installation of Fixed Combustible Gas Detector

The combustible gas detector is used for flammable gas leak detection and alarming. When the combustible gas leaks and the detector monitors that the gas concentration reaches the set critical point, the flammable gas detector will sound an alarm to remind the staff of taking measures, to prevent explosions, fires, and poisoning accidents, thus ensuring safe production. Once fixed combustible gas detector is installed in place, its position is not easy to change. Therefore, something should be noted before installing the detector.

  1. First of all, it is necessary to find out the place to be monitored where may be leaking points or prone to gas leakage, such as the interface of the pipeline, etc., and analyze the leakage pressure, direction and other factors.
  2. It also needs to judge the direction of leakage of combustible gas when a large number of leakage occurs according to the air flow direction, wind direction and other specific factors on site.
  3. According to the density of the leaked gas (greater or less than air) and the trend of air flow, the downstream position of the gas flow can be considered as the initial installation point.
  4. Figure out the leakage state of the leak point, micro leak or spray-like leak. If it is micro leakage, the combustible gas detector should be installed closer to the leakage point. If the leakage is spray-like, it should be installed slightly away from the leak point.
  5. The installation height of the outdoor gas detector can be selected according to the density of the measured gas. A very important thing to understand is that the detector should be installed on the downwind side.

Gas Detector 3-Wire System

In the realm of gas detection systems, the 3-wire configuration offers a robust wiring solution, especially for applications requiring analog output. This video will show you the 3-wire gas detector wiring.

Gas Detector 4-Wire System

The wiring of the 4-wire gas detector supports the RS485 interface Modbus RTU communication mode. This video will show you the 4-wire gas detector wiring.

Using Cloud Data and 4G for Fixed Gas Detectors

This video will show you about the applications of cloud data and 4G transmission for fixed gas detectors.

Monitoring Combustible Gas in Pipelines

This video will show you how to monitoring combustible gas in pipelines.

Fixed Combustible Gas Detector Remote Control Setup

In this video, it will be discussed how to implement remote control of this instrument. If you want a reliable gas detector to check for any kind of gas smell or anything around your property, you can incorporate this combustible gas detector into your gas connection.

Unboxing, Wiring and Alarm Testing of Fixed Combustible Gas Detector

The fixed combustible gas detector is a life-saving device and it should be an important addition to your protection system. This is a fixed gas detector that is used to help you track down any potential leaks of flammable and toxic gases, and we will show how this thing works by doing some tests.

Product reviews
My questions about the gas detector
5
Emmam
Avatar
9/1/2021 3:15 AM
I am interested in the H2 analyzer you offer and would like to ask a few questions regarding the product:
1. Do you know what the minimum flow rate is that the instrument operates at?
2. Is the accuracy of the instrument with operating range 0-100% the same as what is described in the product description?
3. Is there any cross sensitivity for other gases we should be aware of?
4. Do you know what detection technology is used and how the calibration should be performed?
Could I get a quote for the instrument that has an analysis range 0-100% please?
Was this review helpful? Yes No (0/0)
ATO Responded
For your inquires below, here are the answers:
1. The minimum flow rate is 500mL/min.
2. Yes, the 0-100% accuracy of the instrument working range is as described in the product description.
3. For the range 0-100%VOL, it can only be used in a single hydrogen environment, no other gas exists.
4. Measurement technology is sensor semiconductor principle, calibration is with pure hydrogen 99.999%VOL standard gas calibration.
Can I buy the sensor head separately?
5
Isrealg
Avatar
1/18/2022 1:13 AM
Can we buy the sensor head separately if needed in the future?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you can, but the price is approximately 80% of the whole sensor price.
Good fixed combustible gad detector
5
Mar
Avatar
6/30/2022 3:31 AM
The gas detector is fairly easy to use and understand. The C02 reads around 400ppm with my windows open and about 1500ppm after an 8 hour sleep with the windows closed so it seems fairly accurate.
Was this review helpful? Yes No (0/0)
Perfect fixed combustible gas detector
5
Farrah
Avatar
7/26/2022 9:22 PM
This fixed combustible gas detector is perfect, both in terms of shape and performance, it is the best. I've been using this gas detector for three months and haven't found any problems so far.
Was this review helpful? Yes No (0/0)
Can we install the sensor 30 feet from the transmitter?
5
DeLisle
Avatar
12/12/2022 8:22 PM
I wanna know if I buy one gas detector LEL 0-100% with remote,also needs a calibration kit, the sensor can be replaced only? Can we install the sensor 30 feet from the transmitter?
Was this review helpful? Yes No (0/0)
ATO Responded
Fixed Combustible Gas Detector 0 to 100% LEL, with remote control (the remote control distance is about 8-10 meters), and the sensor can be replaced individually. The calibration kit that comes with the Detector is a brass pressure-reducing valve.
Would this gas detector need to be protected against weather conditions?
5
Hahn
Avatar
3/2/2023 12:36 AM
The gas detector would be mounted outside in various conditions, would not be mounted to the gas skid, but be mounted on its own stand to compensate for wind direction when in operation. Oil and gas drilling and completions operations. Would this gas detector need to be protected against weather conditions?
Was this review helpful? Yes No (0/0)
ATO Responded
When installing a fixed gas detector outdoors, we recommend that you install a rain shield against weather conditions.
Refrigerant Leak Detection
4
Donas
Avatar
5/26/2026 9:00 PM
Does your company have a leak detector similar to the GD300-EX? We are looking for a detector for R290 refrigerant leak detection to use on our production line.
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, our current gas detectors cannot be used to detect refrigerant leaks. No suitable recommendations are available.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Fixed combustible gas detector is 24-hour oneline to monitor the leakage of combustible gas 0 to 100% LEL, widely applied in the confined space, gas pipeline area, gas station, material spraying workshop, chemical industry, and other flammable and explosive gas storage area.

Features

  • Adopting high precision sensor for accurate gas leak detection.
  • Equipped with 3-wire system 4-20mA and RS485 output, relay output, (optional).
  • Compatible with various controlled alarms, PLC, DCS and other control system, and can be remote monitored.
  • Explosion-proof design, fast, relaible and stable.
  • Infrared ray controller can remote control the alarm point settings, zero calibration, and address modification.
  • Two-stage alarm with sound and light, and the alarm point is settable.
  • With self-calibration function, and three standard keys will be used to realize on-site maintenance.
  • Can output one or two on-off signals, can drive ventilator, solenoid valve or other external devices.

Specification

ModelGD300-EX
Detection PrincipleCatalytic Combustion
GasCombustible Gas (EX)
Range (Optional)0 to 100% LEL
Resolution1% LEL
Calibration KitGas pressure regulator (calibration gas cylinder NOT included)
Accuracy≤±3% F.S.
Responce Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Signal Output (Optional)4-20mA and RS485
Relay output: one group of relay output (1NO+1NC, 5A/30V) for one alarm (default), or two groups of relay output (2NO+2NC, 5A/30V) for high/low alarm (optional).
AlarmsSound, light
DisplayHigh light nixie tube display
InstallationWall-mounted, piping type, flow-type (according to the detected environment)
ConnectionG1/2 is the inlet and outlet for power and signal lines
Pipe-mounted type: The installation thread size of the instrument is M45*P2.0
Operating Time24h
Explosion-proof GradeII 2G Ex db IIC T4 Gb
Protection GradeIP65
CertificationCE, ATEX
Working Voltage12~36V DC
Case MaterialDie-casting aluminum housing
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Dimension206*179*90mm
Weight≤1.6kg
Power AdapterInput 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug, AU plug or UK plug)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube


Notes

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

Dimensions (Unit: mm)

Fixed gas detector dimensions

Installation Guide

The following precautions apply when connecting the GD300 series fixed gas detector to a pipeline:

  1. Working pressure should be stable at 1 bar ±10%, and the flow rate should be controlled at 300 mL/min.
  2. Working temperature is -20°C to +50°C.
  3. Working humidity is 0–95% RH. When the humidity is above 60% RH, it is recommended to use a dehumidifier or add a filter. When the humidity is above 95% RH, the gas is essentially saturated with water, making measurement impossible.
  4. The gas detector should be installed indoors. If it is installed outdoors, a rain cover should be added to protect the entire instrument.
  5. For the second pipeline connection method of the GD300 gas detector, the pipe-mounted installation, the detector mounting thread size is M45 × P2.0. During installation, hold the detector with both hands, keeping the sensor parallel to the mounting thread. Align it with the threaded port, rotate the detector clockwise, and install it in the desired position. To prevent gas leakage at the threaded connection, an appropriate amount of thread seal tape can be wrapped around the sensor head thread before installation.

***Other Common Gases and Ranges Available for Fixed Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/10/50/100/200/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/9999ppm, 0-2/5/10/20/25/30/50/100%VOL0.1ppm/1ppm/0.001%VOL/0.01%VOL/0.1%VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Combustible Gas (EX)0-100%LEL1%LEL
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100%LEL1%LEL
Hydrogen (H2)0-10/20/500/1000/2000/5000/9999ppm, 0-2/4% VOL, 0-100% LEL0.1ppm/1ppm/0.001%VOL/1%LEL
Hydrogen Chloride (HCL)0-10/20/50/100/200ppm0.01ppm/0.1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Sulfide (H2S)0-5/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Methane (CH4)0-50/100%VOL, 0-100%LEL0.01%VOL/0.1%VOL/1%LEL
Nitric Oxide (NO)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99/0-100%VOL0.01%VOL/0.1%VOL
Nitrogen Dioxide (NO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen Oxides (NOX)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25/30/100%VOL0.01%VOL/0.1%VOL
Ozone (O3)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm

Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.

Details

Fixed Combustible Gas Detector Details

Tips: Installation of Fixed Combustible Gas Detector

The combustible gas detector is used for flammable gas leak detection and alarming. When the combustible gas leaks and the detector monitors that the gas concentration reaches the set critical point, the flammable gas detector will sound an alarm to remind the staff of taking measures, to prevent explosions, fires, and poisoning accidents, thus ensuring safe production. Once fixed combustible gas detector is installed in place, its position is not easy to change. Therefore, something should be noted before installing the detector.

  1. First of all, it is necessary to find out the place to be monitored where may be leaking points or prone to gas leakage, such as the interface of the pipeline, etc., and analyze the leakage pressure, direction and other factors.
  2. It also needs to judge the direction of leakage of combustible gas when a large number of leakage occurs according to the air flow direction, wind direction and other specific factors on site.
  3. According to the density of the leaked gas (greater or less than air) and the trend of air flow, the downstream position of the gas flow can be considered as the initial installation point.
  4. Figure out the leakage state of the leak point, micro leak or spray-like leak. If it is micro leakage, the combustible gas detector should be installed closer to the leakage point. If the leakage is spray-like, it should be installed slightly away from the leak point.
  5. The installation height of the outdoor gas detector can be selected according to the density of the measured gas. A very important thing to understand is that the detector should be installed on the downwind side.

Product reviews
My questions about the gas detector
5
Emmam
Avatar
9/1/2021 3:15 AM
I am interested in the H2 analyzer you offer and would like to ask a few questions regarding the product:
1. Do you know what the minimum flow rate is that the instrument operates at?
2. Is the accuracy of the instrument with operating range 0-100% the same as what is described in the product description?
3. Is there any cross sensitivity for other gases we should be aware of?
4. Do you know what detection technology is used and how the calibration should be performed?
Could I get a quote for the instrument that has an analysis range 0-100% please?
Was this review helpful? Yes No (0/0)
ATO Responded
For your inquires below, here are the answers:
1. The minimum flow rate is 500mL/min.
2. Yes, the 0-100% accuracy of the instrument working range is as described in the product description.
3. For the range 0-100%VOL, it can only be used in a single hydrogen environment, no other gas exists.
4. Measurement technology is sensor semiconductor principle, calibration is with pure hydrogen 99.999%VOL standard gas calibration.
Can I buy the sensor head separately?
5
Isrealg
Avatar
1/18/2022 1:13 AM
Can we buy the sensor head separately if needed in the future?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you can, but the price is approximately 80% of the whole sensor price.
Good fixed combustible gad detector
5
Mar
Avatar
6/30/2022 3:31 AM
The gas detector is fairly easy to use and understand. The C02 reads around 400ppm with my windows open and about 1500ppm after an 8 hour sleep with the windows closed so it seems fairly accurate.
Was this review helpful? Yes No (0/0)
Perfect fixed combustible gas detector
5
Farrah
Avatar
7/26/2022 9:22 PM
This fixed combustible gas detector is perfect, both in terms of shape and performance, it is the best. I've been using this gas detector for three months and haven't found any problems so far.
Was this review helpful? Yes No (0/0)
Can we install the sensor 30 feet from the transmitter?
5
DeLisle
Avatar
12/12/2022 8:22 PM
I wanna know if I buy one gas detector LEL 0-100% with remote,also needs a calibration kit, the sensor can be replaced only? Can we install the sensor 30 feet from the transmitter?
Was this review helpful? Yes No (0/0)
ATO Responded
Fixed Combustible Gas Detector 0 to 100% LEL, with remote control (the remote control distance is about 8-10 meters), and the sensor can be replaced individually. The calibration kit that comes with the Detector is a brass pressure-reducing valve.
Would this gas detector need to be protected against weather conditions?
5
Hahn
Avatar
3/2/2023 12:36 AM
The gas detector would be mounted outside in various conditions, would not be mounted to the gas skid, but be mounted on its own stand to compensate for wind direction when in operation. Oil and gas drilling and completions operations. Would this gas detector need to be protected against weather conditions?
Was this review helpful? Yes No (0/0)
ATO Responded
When installing a fixed gas detector outdoors, we recommend that you install a rain shield against weather conditions.
Refrigerant Leak Detection
4
Donas
Avatar
5/26/2026 9:00 PM
Does your company have a leak detector similar to the GD300-EX? We are looking for a detector for R290 refrigerant leak detection to use on our production line.
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, our current gas detectors cannot be used to detect refrigerant leaks. No suitable recommendations are available.
Only registered users can write reviews
Customers who bought this item also bought

Fixed Hydrogen Sulfide (H2S) Gas Detector, 0 to 50/100/200 ppm

GD300-H2S
$486.77
Fixed H2S gas detector is 24 hours online to detect the hydrogen sulfide and gives sound and light alarm with measuring range from 0 to 50 ppm, 0 to 100 ppm, or 0 to 200 ppm. High accuracy and reliability hydrogen sulfide detector has real-time display and infrared remote control with optional output signal 4-20mA and RS485.

Fixed Ammonia (NH3) Gas Detector, 0 to 50/100/200 ppm

GD300-NH3
$754.13
Fixed ammonia gas detector is used to detect the concentration of NH3 with selectable measuring range of 0 to 50/100/200/500/1000/2000/5000 ppm. NH3 detector with sound and light alarm and real-time display, signal output 4-20mA and RS485, high accuracy, high reliability and low price.

Fixed Hydrogen (H2) Gas Detector, 0 to 1000/2000/5000 ppm

GD300-H2
$634.77
Affordable price hydrogen gas detector for sale. Optional measuring range 0-1000/2000/5000 ppm, max 10000 ppm, supports remote control with output signal 4-20mA and RS485, high accuracy 3% F.S. H2 gas leak detector for hydrogen concentration detecting with sound & light alarm, fixed design, compact structure.

Fixed Carbon Dioxide (CO2) Gas Detector, 0 to 9999 ppm

GD300-CO2
$757.85
Economical price fixed gas detector from ideal supplier, for carbon dioxide detection. Measuring range 0-1000/2000/5000/9999 ppm for selection, remote control output signal 4-20mA and RS485, monitor CO2 concentration and sound & light alarm, high accuracy 3% F.S, fast response within 10s, 24h work and real-time display.

Fixed Nitrogen (N2) Gas Detector, 0 to 100% Vol

GD300-N2
$742.46
Buy nitrogen gas detector from high-quality manufacturer at good price. Measuring range 0-100% Vol, supports remote control, optional output signal 4-20mA and RS485, high accuracy 3% F.S, fast response within 10s. N2 gas detector for nitrogen concentration detecting and leak monitor, sound and light alarm, 24h online, real-time display, fixed mounting.