Fixed Chlorine Dioxide (ClO2) Gas Detector, 0 to 1/5/10/20/50/100 ppm

$914.99
Economical price fixed Chlorine Dioxide (ClO2) gas detector for sale, with sound & light alarm, advanced sensor, optional measuring ranges of 0-1/5/10/20/50/100ppm. This Chlorine Dioxide monitor is commonly used in industrial settings where ClO2 gas may be present, such as water treatment plants, paper mills, and chemical processing facilities.
SKU: GD300-CLO2
*
*
*
*
*
Free Shipping
Delivery date: 6-12 days

Fixed Chlorine Dioxide gas detector is equipped with sound & light alarms to notify workers of dangerous ClO2 gas levels, allowing them to take immediate action to mitigate risks and ensure the safety of personnel and the surrounding environment.

Features

  • Fixed ClO2 gas detector adopts high precision sensor for accurate gas leak detection.
  • Chlorine Dioxide detector is equipped with 3-wire system 4-20mA analog output, relay output, RS485 output (optional).
  • The Chlorine Dioxide gas monitor is compatible with various controlled alarms, PLC, DCS and other control system, and can be remote monitored.
  • Explosion-proof design, fast, relaible and stable.
  • Infrared ray controller can remote control the alarm point settings, zero calibration, and address modification.
  • Two-stage alarm with sound and light, and the alarm point is settable.
  • The industrial ClO2 gas detector has self-calibration function, and three standard keys will be used to realize on-site maintenance.
  • Fixed ClO2 gas detector can output one or two on-off signals, can drive ventilator, solenoid valve or other external devices.

Specification

>

ModelGD300-ClO2
Detection PrincipleElectrochemistry
GasChlorine Dioxide (ClO2)
Range (Optional)0 to 1ppm, 0-5ppm, 0 to 10ppm, 0 to 20ppm, 0 to 50ppm, 0 to 100ppm
Resolution0.001ppm (0-1/5ppm), 0.01ppm (0-10/20/50ppm), 0.1ppm (0-100ppm)
Calibration KitGas pressure regulator (calibration gas cylinder NOT included)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Signal Output (Optional)4-20mA and RS485
Relay output: one group of relay output (1NO+1NC, 5A/30V) for one alarm (default), or two groups of relay output (2NO+2NC, 5A/30V) for high/low alarm (optional).
AlarmsSound, light
DisplayHigh light nixie tube display
InstallationWall-mounted, piping type, flow-type (according to the detected environment)
ConnectionPower connection type: G1/2 male thread explosion-proof flexible pipe
Pipe-mounted type: M45*P2.0
Operating Time24h
Explosion-proof GradeII 2G Ex db IIC T4 Gb
Protection GradeIP65
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Working Voltage12-36V DC
Case MaterialDie-casting aluminum housing
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Dimension206*179*90mm
Weight≤1.6kg
Power AdapterInput 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug, AU plug or UK plug)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Stainless steel
  • Input Range of Pressure Gauge: 0-25MPa
  • Output Range of Pressure Gauge: 0-0.6Mpa
  • Gauge Class: 2.5
  • Input Pressure: ≤15MPa
  • Output Pressure: ≤0.45MPa
  • Rated Flow: 0.6 m3/h
  • Connection: Inlet: W21.8-14 teeth/inch (levorotation, dextrorotation) ; Outlet: Ф6 flexible tube


Notes

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

Dimensions (Unit: mm)

Fixed gas detector dimensions

Installation Guide

The following precautions apply when connecting the GD300 series fixed gas detector to a pipeline:

    1. Working pressure should be stable at 1 bar ±10%, and the flow rate should be controlled at 300 mL/min.
    2. Working temperature is -20°C to +50°C.
    3. Working humidity is 0–95% RH. When the humidity is above 60% RH, it is recommended to use a dehumidifier or add a filter. When the humidity is above 95% RH, the gas is essentially saturated with water, making measurement impossible.
    4. The gas detector should be installed indoors. If it is installed outdoors, a rain cover should be added to protect the entire instrument.
    5. For the second pipeline connection method of the GD300 gas detector, the pipe-mounted installation, the detector mounting thread size is M45 × P2.0. During installation, hold the detector with both hands, keeping the sensor parallel to the mounting thread. Align it with the threaded port, rotate the detector clockwise, and install it in the desired position. To prevent gas leakage at the threaded connection, an appropriate amount of thread seal tape can be wrapped around the sensor head thread before installation.

***Other Common Gases and Ranges Available for Fixed Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/10/50/100/200/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/9999ppm, 0-2/5/10/20/25/30/50/100%VOL0.1ppm/1ppm/0.001%VOL/0.01%VOL/0.1%VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Combustible Gas (EX)0-100%LEL1%LEL
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100%LEL1%LEL
Hydrogen (H2)0-10/20/500/1000/2000/5000/9999ppm, 0-2/4% VOL, 0-100% LEL0.1ppm/1ppm/0.001%VOL/1%LEL
Hydrogen Chloride (HCL)0-10/20/50/100/200ppm0.01ppm/0.1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Sulfide (H2S)0-5/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Methane (CH4)0-50/100%VOL, 0-100%LEL0.01%VOL/0.1%VOL/1%LEL
Nitric Oxide (NO)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99/0-100%VOL0.01%VOL/0.1%VOL
Nitrogen Dioxide (NO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen Oxides (NOX)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25/30/100%VOL0.01%VOL/0.1%VOL
Ozone (O3)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm

Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.

Details

Fixed Chlorine Dioxide (ClO2) Gas Detector Details

Tips: What is Chlorine Dioxide (ClO2) and why is it important to detect it?

Chlorine Dioxide gas is a yellow to reddish-yellow gas with a Chlorine-like odor, used primarily as a disinfectant and bleaching agent. It is effective in killing bacteria, viruses, and some types of parasites, making it crucial in water treatment, food processing, and healthcare settings. Detecting ClO2 is essential because of its dual nature: while beneficial in controlled amounts, it poses health risks at high concentrations, including respiratory irritation and oxidative damage. Monitoring ClO2 levels ensures safe usage, protects public health, and complies with environmental regulations. Effective detection helps maintain the delicate balance between its beneficial disinfectant properties and its potential toxicity, ensuring safe and efficient use in various applications.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Fixed Chlorine Dioxide gas detector is equipped with sound & light alarms to notify workers of dangerous ClO2 gas levels, allowing them to take immediate action to mitigate risks and ensure the safety of personnel and the surrounding environment.

Features

  • Fixed ClO2 gas detector adopts high precision sensor for accurate gas leak detection.
  • Chlorine Dioxide detector is equipped with 3-wire system 4-20mA analog output, relay output, RS485 output (optional).
  • The Chlorine Dioxide gas monitor is compatible with various controlled alarms, PLC, DCS and other control system, and can be remote monitored.
  • Explosion-proof design, fast, relaible and stable.
  • Infrared ray controller can remote control the alarm point settings, zero calibration, and address modification.
  • Two-stage alarm with sound and light, and the alarm point is settable.
  • The industrial ClO2 gas detector has self-calibration function, and three standard keys will be used to realize on-site maintenance.
  • Fixed ClO2 gas detector can output one or two on-off signals, can drive ventilator, solenoid valve or other external devices.

Specification

>

ModelGD300-ClO2
Detection PrincipleElectrochemistry
GasChlorine Dioxide (ClO2)
Range (Optional)0 to 1ppm, 0-5ppm, 0 to 10ppm, 0 to 20ppm, 0 to 50ppm, 0 to 100ppm
Resolution0.001ppm (0-1/5ppm), 0.01ppm (0-10/20/50ppm), 0.1ppm (0-100ppm)
Calibration KitGas pressure regulator (calibration gas cylinder NOT included)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Signal Output (Optional)4-20mA and RS485
Relay output: one group of relay output (1NO+1NC, 5A/30V) for one alarm (default), or two groups of relay output (2NO+2NC, 5A/30V) for high/low alarm (optional).
AlarmsSound, light
DisplayHigh light nixie tube display
InstallationWall-mounted, piping type, flow-type (according to the detected environment)
ConnectionPower connection type: G1/2 male thread explosion-proof flexible pipe
Pipe-mounted type: M45*P2.0
Operating Time24h
Explosion-proof GradeII 2G Ex db IIC T4 Gb
Protection GradeIP65
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Working Voltage12-36V DC
Case MaterialDie-casting aluminum housing
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Dimension206*179*90mm
Weight≤1.6kg
Power AdapterInput 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug, AU plug or UK plug)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Stainless steel
  • Input Range of Pressure Gauge: 0-25MPa
  • Output Range of Pressure Gauge: 0-0.6Mpa
  • Gauge Class: 2.5
  • Input Pressure: ≤15MPa
  • Output Pressure: ≤0.45MPa
  • Rated Flow: 0.6 m3/h
  • Connection: Inlet: W21.8-14 teeth/inch (levorotation, dextrorotation) ; Outlet: Ф6 flexible tube


Notes

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

Dimensions (Unit: mm)

Fixed gas detector dimensions

Installation Guide

The following precautions apply when connecting the GD300 series fixed gas detector to a pipeline:

    1. Working pressure should be stable at 1 bar ±10%, and the flow rate should be controlled at 300 mL/min.
    2. Working temperature is -20°C to +50°C.
    3. Working humidity is 0–95% RH. When the humidity is above 60% RH, it is recommended to use a dehumidifier or add a filter. When the humidity is above 95% RH, the gas is essentially saturated with water, making measurement impossible.
    4. The gas detector should be installed indoors. If it is installed outdoors, a rain cover should be added to protect the entire instrument.
    5. For the second pipeline connection method of the GD300 gas detector, the pipe-mounted installation, the detector mounting thread size is M45 × P2.0. During installation, hold the detector with both hands, keeping the sensor parallel to the mounting thread. Align it with the threaded port, rotate the detector clockwise, and install it in the desired position. To prevent gas leakage at the threaded connection, an appropriate amount of thread seal tape can be wrapped around the sensor head thread before installation.

***Other Common Gases and Ranges Available for Fixed Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/10/50/100/200/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/9999ppm, 0-2/5/10/20/25/30/50/100%VOL0.1ppm/1ppm/0.001%VOL/0.01%VOL/0.1%VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Combustible Gas (EX)0-100%LEL1%LEL
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100%LEL1%LEL
Hydrogen (H2)0-10/20/500/1000/2000/5000/9999ppm, 0-2/4% VOL, 0-100% LEL0.1ppm/1ppm/0.001%VOL/1%LEL
Hydrogen Chloride (HCL)0-10/20/50/100/200ppm0.01ppm/0.1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Sulfide (H2S)0-5/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Methane (CH4)0-50/100%VOL, 0-100%LEL0.01%VOL/0.1%VOL/1%LEL
Nitric Oxide (NO)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99/0-100%VOL0.01%VOL/0.1%VOL
Nitrogen Dioxide (NO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen Oxides (NOX)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25/30/100%VOL0.01%VOL/0.1%VOL
Ozone (O3)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm

Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.

Details

Fixed Chlorine Dioxide (ClO2) Gas Detector Details

Tips: What is Chlorine Dioxide (ClO2) and why is it important to detect it?

Chlorine Dioxide gas is a yellow to reddish-yellow gas with a Chlorine-like odor, used primarily as a disinfectant and bleaching agent. It is effective in killing bacteria, viruses, and some types of parasites, making it crucial in water treatment, food processing, and healthcare settings. Detecting ClO2 is essential because of its dual nature: while beneficial in controlled amounts, it poses health risks at high concentrations, including respiratory irritation and oxidative damage. Monitoring ClO2 levels ensures safe usage, protects public health, and complies with environmental regulations. Effective detection helps maintain the delicate balance between its beneficial disinfectant properties and its potential toxicity, ensuring safe and efficient use in various applications.

Only registered users can write reviews