Electromagnetic Relay, 8-pin DPDT, 12V/24V/110V/220V

$53.77
Available for 12V/24V DC, 110V/220V AC coil voltage, electromagnetic relay features DPDT contact configuration, 8 pins with plug-in terminals, contact load 10A/240V AC 28V DC. Favorable price and high quality.
SKU: ATO-EMR-13F2Z
*
Free Shipping
Delivery date: 6-12 days

8-pin DPDT electromagnetic relay is general purpose in compact size with low price and high quality, and has a wide range of applications such as remote control, electronic equipment, communication equipment, automatic control system and tools and so on.

Specification

BasicsModelATO-JQX-13F-2Z (Relay with Socket)
Dimension (L*W*H)27×21×35mm
Weight40g
Ambient Temperature-25℃~+55℃
Terminal TypePlug in
Number of Pins8
Technical ParametersContact FormDPDT
Contact MaterialSilver alloy
Contact Capacity (Resistive load)10A/240V AC 28V DC
Coil PowerDC≤0.9W, AC≤1.2VA
Coil VoltageOptional: 12V DC, 24V DC, 12V AC, 24V AC, 36V AC, 110V AC, 220V AC
Pick-up Voltage at 23℃DC≤75%, AC≤80%
Drop-out Voltage at 23℃DC≥10%, AC≥30%
Contact Resistance @6V DC 1A≤100MΩ
Dielectric StrengthBetween open contact≥1200V AC 50Hz/1min
Between adjacent contact≥1500V AC 50Hz/1min
Between coil & contact≥1500VAC 50Hz/1min
Leakage current≤1mA
Insulation Resistance (MΩ)≥500MΩ at 500V DC
Service lifeElectrical105 Times (Frequency: On 1 Time/1s, Off 1 Time/1s)
Mechanical106 Times (Frequency: 300 Time/1min)

Note: Here just shows the contact form DPDT, and another contact forms 2NO and 2NC are still available. What's more, please kindly note that other coil voltages are also available(DC: 6-220V; AC: 6-380V). If you have any requirments, please don't hesitate to contact us.

Dimensions & Connection Diagram
JQX-13F-2Z Electromangetic Relay Dimensions and Connection Diagram

Details

Electromagnetic Relay,8-pin DPDT Details

Tips: How to test an electromagnetic relay?

  1. Test of coil resistance: use multimeter to measure resistance of relay coil to judge whether the coil is bothered with open circuit. Resistance of the relay coil is closely related to its working voltage and working current. Working voltage and working current of the coil can be calculated according to its resistance.
  2. Test of contact resistance: turn the multimeter to its resistance mode and use it to measure resistance of normally closed contact and movable contact. Their resistance is supposed to be 0. If resistance appears unstable or bigger than the value, that means the contract is bothered with poor contact. If the resistance of the normally open contact and movable contact appears infinite, the condition shall be judged as contact adhesion. By this way, users can distinguish which one is normally closed contact, which one is normally open contact and whether the relay is in good condition (especially for used relay).

Contactors are widely used in industrial equipment. It is a common application to control 110V/120V/220V/240V AC contactors with 12V/24V/36V DC relays. Users can use this method to control unsafe voltages. This video will show you how to use AC contactor with a relay at safe voltage.

Electromagnetic Relay Applications

Electromagnetic relays are key components in electrical engineering and play an important role in various applications. In this video, we will look at why electromagnetic relays are important in our lives.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Perfect 8-pin electromagnetic relay
5
Dezumar
Avatar
10/26/2022 12:07 AM
I was building a custom sound system in my project car requiring the placement of the amp and crossovers in an accessible location. So I incorporated this 8 pin electromagnetic relay to connect the fans to the amp power source when the radio was on. And the system works perfectly.
Was this review helpful? Yes No (0/0)
For my water conditioning system
5
Harless
Avatar
12/15/2022 1:37 AM
I have a water conditioning system in my unheated garage. This electromagnetic relay in conjunction with a old style thermostat and incandescent light keep the enclosure above 40 DegF. I will order more.
Was this review helpful? Yes No (0/0)
About polarity
5
Raoul
Avatar
10/9/2024 12:23 AM
When connecting to the coil at 7 and 8 does polarity matter when connected or no? I’m guessing not since current in either direction will energize the coil either way but not sure if there is a diode for protection in place these connections. Thank you.
Was this review helpful? Yes No (0/0)
ATO Responded
The 24VDC coil of the relay has positive and negative polarity, pin 7 is 0V, and pin 8 is +24VDC.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

8-pin DPDT electromagnetic relay is general purpose in compact size with low price and high quality, and has a wide range of applications such as remote control, electronic equipment, communication equipment, automatic control system and tools and so on.

Specification

BasicsModelATO-JQX-13F-2Z (Relay with Socket)
Dimension (L*W*H)27×21×35mm
Weight40g
Ambient Temperature-25℃~+55℃
Terminal TypePlug in
Number of Pins8
Technical ParametersContact FormDPDT
Contact MaterialSilver alloy
Contact Capacity (Resistive load)10A/240V AC 28V DC
Coil PowerDC≤0.9W, AC≤1.2VA
Coil VoltageOptional: 12V DC, 24V DC, 12V AC, 24V AC, 36V AC, 110V AC, 220V AC
Pick-up Voltage at 23℃DC≤75%, AC≤80%
Drop-out Voltage at 23℃DC≥10%, AC≥30%
Contact Resistance @6V DC 1A≤100MΩ
Dielectric StrengthBetween open contact≥1200V AC 50Hz/1min
Between adjacent contact≥1500V AC 50Hz/1min
Between coil & contact≥1500VAC 50Hz/1min
Leakage current≤1mA
Insulation Resistance (MΩ)≥500MΩ at 500V DC
Service lifeElectrical105 Times (Frequency: On 1 Time/1s, Off 1 Time/1s)
Mechanical106 Times (Frequency: 300 Time/1min)

Note: Here just shows the contact form DPDT, and another contact forms 2NO and 2NC are still available. What's more, please kindly note that other coil voltages are also available(DC: 6-220V; AC: 6-380V). If you have any requirments, please don't hesitate to contact us.

Dimensions & Connection Diagram
JQX-13F-2Z Electromangetic Relay Dimensions and Connection Diagram

Details

Electromagnetic Relay,8-pin DPDT Details

Tips: How to test an electromagnetic relay?

  1. Test of coil resistance: use multimeter to measure resistance of relay coil to judge whether the coil is bothered with open circuit. Resistance of the relay coil is closely related to its working voltage and working current. Working voltage and working current of the coil can be calculated according to its resistance.
  2. Test of contact resistance: turn the multimeter to its resistance mode and use it to measure resistance of normally closed contact and movable contact. Their resistance is supposed to be 0. If resistance appears unstable or bigger than the value, that means the contract is bothered with poor contact. If the resistance of the normally open contact and movable contact appears infinite, the condition shall be judged as contact adhesion. By this way, users can distinguish which one is normally closed contact, which one is normally open contact and whether the relay is in good condition (especially for used relay).
Product reviews
Perfect 8-pin electromagnetic relay
5
Dezumar
Avatar
10/26/2022 12:07 AM
I was building a custom sound system in my project car requiring the placement of the amp and crossovers in an accessible location. So I incorporated this 8 pin electromagnetic relay to connect the fans to the amp power source when the radio was on. And the system works perfectly.
Was this review helpful? Yes No (0/0)
For my water conditioning system
5
Harless
Avatar
12/15/2022 1:37 AM
I have a water conditioning system in my unheated garage. This electromagnetic relay in conjunction with a old style thermostat and incandescent light keep the enclosure above 40 DegF. I will order more.
Was this review helpful? Yes No (0/0)
About polarity
5
Raoul
Avatar
10/9/2024 12:23 AM
When connecting to the coil at 7 and 8 does polarity matter when connected or no? I’m guessing not since current in either direction will energize the coil either way but not sure if there is a diode for protection in place these connections. Thank you.
Was this review helpful? Yes No (0/0)
ATO Responded
The 24VDC coil of the relay has positive and negative polarity, pin 7 is 0V, and pin 8 is +24VDC.
Only registered users can write reviews
Customers who bought this item also bought

Proximity Sensor, Inductive, M18, 3 Wire, 120V

ATO-PROS-I18
$39.45
M18 inductive proximity sensor can detect a variety of metals, small size, long life, cheap price, unshielded type installation, anti-interference ability, 8mm detection distance, supply voltage AC 120V, manufacturer direct sale. The delay distance of the inductive proximity sensor is ≤10% of the detection range, and the protection level reaches IP67, which can operate reliably in harsh industrial environments.