Electromagnetic Relay, 8-pin DPDT, 12V/24V/110V/220V coil

$53.69
Electromagnetic relay with plug-in terminals, 8 pins DPDT, silver alloy contacts, optional coil volatge 12V DC, 24V DC, 110V AC and 220V AC, contact load 10A/250V AC 28V DC, compact size and clear plastic housing.
SKU: ATO-EMR-MK2P1
*
Free Shipping
Delivery date: 6-12 days

8-pin electromagnetic relay with DPDT contact configuration can be widely used in remote control, electronic equipment, communication equipment, automatic control system and tools etc. Low cost and high quality.
This video introduces the MK 2P-I series electromagnetic relay provided by ATO. With its convenient wiring, rapid reset, durable construction, and consistent performance, this relay promises enhanced safety and efficiency in electric circuit management.

Specification

BasicsModelATO-MK2P-1 (Relay with Socket)
Dimension (L*W*H)35×35×53mm
Weight76g
Ambient Temperature-25℃~+55℃
Terminal TypePlug in
Number of Pins8
Technical ParametersContact FormDPDT
Contact MaterialSilver alloy
Contact Capacity (Resistive load)10A/250V AC 28V DC
Coil PowerDC≤2W, AC≤3.5VA
Coil VoltageOptional: 12V DC, 24V DC, 12V AC, 24V AC, 36V AC, 110V AC, 220V AC
Pick-up Voltage at 23℃DC≤75%, AC≤80%
Drop-out Voltage at 23℃DC≥10%, AC≥30%
Contact Resistance @6V DC 1A≤100MΩ
Dielectric StrengthBetween open contact≥1200V AC 50Hz/1min
Between adjacent contact≥1500V AC 50Hz/1min
Between coil & contact≥1500VAC 50Hz/1min
Leakage current≤1mA
Insulation Resistance (MΩ)≥500MΩ at 500V DC
Service lifeElectrical105 Times (Frequency: On 1 Time/1s, Off 1 Time/1s)
Mechanical106 Times (Frequency: 300 Time/1min)

Note: Here just shows the contact form DPDT, and another contact forms 2NO and 2NC are still available. What's more, please kindly note that other coil voltages are also available(DC: 6-220V; AC: 6-380V). If you have any requirments, please don't hesitate to contact us.

Dimensions & Connection Diagram
MK2P electromangetic relay dimensions connection diagramRelay Socket Size
MK2P 1 electromagnetic relay socket sizeDetails

Electromagnetic Relay, 8-pin DPDT Details

Tips: Applications of electromagnetic relays

  1. Flood alarm: open or close a circuit by changes of water level to realize alarm function.
    When the water level exceeds the warning line, the floater will float up. As a result, the circuit will be closed and the electromagnet will attract the armature. Then, alarm indicator is powered on to alarm users.
  2. Automatic temperature alarm: the level of mercury changes with temperature. Its changes could be used to control opening and closing of the circuit and realize function of the automatic temperature alarm. When temperature rises to a threshold value, mercury in the thermometer will rise to the wire. Mercury is a kind of conductor, so it could be used to close the circuit of the electromagnetic system. As a result, the electromagnet will attract the spring and close the alarm circuit to make it ring up. When temperature falls, mercury in the thermometer will be disconnected from the wire. Consequently, the spring will restore its position and the electromagnetic circuit will be opened to silence the alarm.

The Difference Between Solid State Relays and Electromagnetic Relays

SSR and EMR are both commonly used electrical control components. Their main difference is that solid state relays are usually based on semiconductor technology and have no mechanical contacts, while electromagnetic relays rely on electromagnetic effects to control the opening and closing of switches. Taken together, SSR have advantages in response speed, durability, and anti-interference capabilities, and are particularly suitable for application scenarios that require fast response and high precision. The EMR performs better in terms of cost and heat dissipation requirements, and is suitable for cost-sensitive applications with low heat dissipation requirements.

Contactors are widely used in industrial equipment. It is a common application to control 110V/120V/220V/240V AC contactors with 12V/24V/36V DC relays. Users can use this method to control unsafe voltages. This video will show you how to use AC contactor with a relay at safe voltage.

Electromagnetic Relay Applications

Electromagnetic relays are key components in electrical engineering and play an important role in various applications. In this video, we will look at why electromagnetic relays are important in our lives.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Works perfectly
5
sbn
Avatar
4/21/2022 8:23 PM
Needed to get remote power with a 120VAC trigger, for some stage lighting, and these relays are going to work out great! I've had the relay installed for 5 days at the time of writing this review. It has performed as expected. I would buy it again, and look into getting a mounting bracket for easier installation.
Was this review helpful? Yes No (0/0)
Handy electromagnetic relay
5
Jeffy
Avatar
1/9/2023 12:45 AM
Equal in quality to any relays I've used in industry applications. Handy LED indicator.  Electromagnetic relays plug in and out of the socket smoothly and firmly. Highly recommended!!!
Was this review helpful? Yes No (0/0)
8-pin Electromagnetic Relay
4
Dennison
Avatar
12/4/2025 11:33 PM
Control relay, 8-pin double-pole double-throw (DPDT) -P/N- REGP0040 We currently need an 8-pin double-pole double-throw (DPDT) control relay.
Was this review helpful? Yes No (0/0)
ATO Responded
You can take a look at our relay, product number: ATO-EMR-MK2P1. We recommend using our 8-pin double-pole double-throw (DPDT) electromagnetic relay.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

8-pin electromagnetic relay with DPDT contact configuration can be widely used in remote control, electronic equipment, communication equipment, automatic control system and tools etc. Low cost and high quality.
This video introduces the MK 2P-I series electromagnetic relay provided by ATO. With its convenient wiring, rapid reset, durable construction, and consistent performance, this relay promises enhanced safety and efficiency in electric circuit management.

Specification

BasicsModelATO-MK2P-1 (Relay with Socket)
Dimension (L*W*H)35×35×53mm
Weight76g
Ambient Temperature-25℃~+55℃
Terminal TypePlug in
Number of Pins8
Technical ParametersContact FormDPDT
Contact MaterialSilver alloy
Contact Capacity (Resistive load)10A/250V AC 28V DC
Coil PowerDC≤2W, AC≤3.5VA
Coil VoltageOptional: 12V DC, 24V DC, 12V AC, 24V AC, 36V AC, 110V AC, 220V AC
Pick-up Voltage at 23℃DC≤75%, AC≤80%
Drop-out Voltage at 23℃DC≥10%, AC≥30%
Contact Resistance @6V DC 1A≤100MΩ
Dielectric StrengthBetween open contact≥1200V AC 50Hz/1min
Between adjacent contact≥1500V AC 50Hz/1min
Between coil & contact≥1500VAC 50Hz/1min
Leakage current≤1mA
Insulation Resistance (MΩ)≥500MΩ at 500V DC
Service lifeElectrical105 Times (Frequency: On 1 Time/1s, Off 1 Time/1s)
Mechanical106 Times (Frequency: 300 Time/1min)

Note: Here just shows the contact form DPDT, and another contact forms 2NO and 2NC are still available. What's more, please kindly note that other coil voltages are also available(DC: 6-220V; AC: 6-380V). If you have any requirments, please don't hesitate to contact us.

Dimensions & Connection Diagram
MK2P electromangetic relay dimensions connection diagramRelay Socket Size
MK2P 1 electromagnetic relay socket sizeDetails

Electromagnetic Relay, 8-pin DPDT Details

Tips: Applications of electromagnetic relays

  1. Flood alarm: open or close a circuit by changes of water level to realize alarm function.
    When the water level exceeds the warning line, the floater will float up. As a result, the circuit will be closed and the electromagnet will attract the armature. Then, alarm indicator is powered on to alarm users.
  2. Automatic temperature alarm: the level of mercury changes with temperature. Its changes could be used to control opening and closing of the circuit and realize function of the automatic temperature alarm. When temperature rises to a threshold value, mercury in the thermometer will rise to the wire. Mercury is a kind of conductor, so it could be used to close the circuit of the electromagnetic system. As a result, the electromagnet will attract the spring and close the alarm circuit to make it ring up. When temperature falls, mercury in the thermometer will be disconnected from the wire. Consequently, the spring will restore its position and the electromagnetic circuit will be opened to silence the alarm.

The Difference Between Solid State Relays and Electromagnetic Relays

SSR and EMR are both commonly used electrical control components. Their main difference is that solid state relays are usually based on semiconductor technology and have no mechanical contacts, while electromagnetic relays rely on electromagnetic effects to control the opening and closing of switches. Taken together, SSR have advantages in response speed, durability, and anti-interference capabilities, and are particularly suitable for application scenarios that require fast response and high precision. The EMR performs better in terms of cost and heat dissipation requirements, and is suitable for cost-sensitive applications with low heat dissipation requirements.

Product reviews
Works perfectly
5
sbn
Avatar
4/21/2022 8:23 PM
Needed to get remote power with a 120VAC trigger, for some stage lighting, and these relays are going to work out great! I've had the relay installed for 5 days at the time of writing this review. It has performed as expected. I would buy it again, and look into getting a mounting bracket for easier installation.
Was this review helpful? Yes No (0/0)
Handy electromagnetic relay
5
Jeffy
Avatar
1/9/2023 12:45 AM
Equal in quality to any relays I've used in industry applications. Handy LED indicator.  Electromagnetic relays plug in and out of the socket smoothly and firmly. Highly recommended!!!
Was this review helpful? Yes No (0/0)
8-pin Electromagnetic Relay
4
Dennison
Avatar
12/4/2025 11:33 PM
Control relay, 8-pin double-pole double-throw (DPDT) -P/N- REGP0040 We currently need an 8-pin double-pole double-throw (DPDT) control relay.
Was this review helpful? Yes No (0/0)
ATO Responded
You can take a look at our relay, product number: ATO-EMR-MK2P1. We recommend using our 8-pin double-pole double-throw (DPDT) electromagnetic relay.
Only registered users can write reviews