14-pin electromagnetic relay with 4PDT contact form in compact size and transparent housing, can adjust automatically, protect and transform the electric circuit and widely used in electronic equipment, communication equipment, automatic equipment and tools etc.

Specification

BasicsModelATO-HH54P/MY4NJ (Relay with Socket)
Dimension (L*W*H)27×21×35mm
Weight40g
Ambient Temperature-25℃~+55℃
Terminal TypePlug-in
Number of Pins14
Technical ParametersContact Form4PDT
Contact MaterialSilver alloy
Contact Capacity (Resistive load)3A/28V DC, 3A/240V AC
Coil PowerDC≤0.9W, AC≤1.2VA
Coil Voltage (Optional)12V DC, 24VDC, 110V AC, 220V AC
Pick-up Voltage at 23℃DC≤75%, AC≤80%
Drop-out Voltage at 23℃DC≥10%, AC≥30%
Contact Resistance @6V DC 1A≤100MΩ
Dielectric StrengthBetween open contact≥1000V AC 50Hz/1min
Between adjacent contact≥1000V AC 50Hz/1min
Between coil & contact≥1500VAC 50Hz/1min
Leakage current≤1mA
Insulation Resistance (MΩ)≥500MΩ at 500V DC
Service lifeElectrical105 Times (Frequency: On 1 Time/1s, Off 1 Time/1s)
Mechanical106 Times (Frequency: 300 Time/1min)

Note: Here just shows the contact form 4PDT, and another contact forms 4NO and 4NC are still available. What's more, please kindly note that other coil voltages are also available(DC: 6-220V; AC: 6-380V). If you have any requirments, please don't hesitate to contact us.

Dimensions & Connection Diagram
HH54PL electromangetic relay dimensions connection diagramDetails

Electromagnetic Relay,4PDT Details

Tips: Structure of electromagnetic relay

Three core parts of electromagnetic relay are electromagnetic system, contact system, transmission mechanism and restoration mechanism.

  1. Electromagnetic system: it is also known as induction mechanism. The electromagnetic system consists of iron core which is made of soft magnetic material, magnetic circuit which is composed with yoke and armature, as well as the coil. When powering on, the electromagnetic system will be provided with magnetism. It is a core part of the electromagnetic relay.
  2. Contact system: it is also known as actuation mechanism. The contract system is assembled by different types of contact springs or contact chips in an insulated way to decide conducting part of the circuit.
  3. Transmission and restoration mechanism: they are also known as intermediate comparison mechanisms. The transmission mechanism is designed to transmit movement of armature to contact spring when the coil is powered on. Contact spring is moved by the contact spring which is connected to the armature or moved by the armature.

Contactors are widely used in industrial equipment. It is a common application to control 110V/120V/220V/240V AC contactors with 12V/24V/36V DC relays. Users can use this method to control unsafe voltages. This video will show you how to use AC contactor with a relay at safe voltage.

Electromagnetic Relay Applications

Electromagnetic relays are key components in electrical engineering and play an important role in various applications. In this video, we will look at why electromagnetic relays are important in our lives.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Small unit, but works well.
5
Richard
Avatar
5/16/2019 1:16 AM
Bought two of this small relay. Once received the units, I installed it and the connection was no problem. I use the relays to control the LED lights.  Works as expected. Great!
Was this review helpful? Yes No (0/0)
Reasonable price for 4PDT electromagnetic relay
5
Drosy
Avatar
10/31/2022 9:16 PM
Hard to find 4PDT electromagnetic relay at a great price! It works great for 24 V DC applications. I use them for converting intercom doorbells over to video doorbells for my customers, but keeping the intercom chime in use.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

14-pin electromagnetic relay with 4PDT contact form in compact size and transparent housing, can adjust automatically, protect and transform the electric circuit and widely used in electronic equipment, communication equipment, automatic equipment and tools etc.

Specification

BasicsModelATO-HH54P/MY4NJ (Relay with Socket)
Dimension (L*W*H)27×21×35mm
Weight40g
Ambient Temperature-25℃~+55℃
Terminal TypePlug-in
Number of Pins14
Technical ParametersContact Form4PDT
Contact MaterialSilver alloy
Contact Capacity (Resistive load)3A/28V DC, 3A/240V AC
Coil PowerDC≤0.9W, AC≤1.2VA
Coil Voltage (Optional)12V DC, 24VDC, 110V AC, 220V AC
Pick-up Voltage at 23℃DC≤75%, AC≤80%
Drop-out Voltage at 23℃DC≥10%, AC≥30%
Contact Resistance @6V DC 1A≤100MΩ
Dielectric StrengthBetween open contact≥1000V AC 50Hz/1min
Between adjacent contact≥1000V AC 50Hz/1min
Between coil & contact≥1500VAC 50Hz/1min
Leakage current≤1mA
Insulation Resistance (MΩ)≥500MΩ at 500V DC
Service lifeElectrical105 Times (Frequency: On 1 Time/1s, Off 1 Time/1s)
Mechanical106 Times (Frequency: 300 Time/1min)

Note: Here just shows the contact form 4PDT, and another contact forms 4NO and 4NC are still available. What's more, please kindly note that other coil voltages are also available(DC: 6-220V; AC: 6-380V). If you have any requirments, please don't hesitate to contact us.

Dimensions & Connection Diagram
HH54PL electromangetic relay dimensions connection diagramDetails

Electromagnetic Relay,4PDT Details

Tips: Structure of electromagnetic relay

Three core parts of electromagnetic relay are electromagnetic system, contact system, transmission mechanism and restoration mechanism.

  1. Electromagnetic system: it is also known as induction mechanism. The electromagnetic system consists of iron core which is made of soft magnetic material, magnetic circuit which is composed with yoke and armature, as well as the coil. When powering on, the electromagnetic system will be provided with magnetism. It is a core part of the electromagnetic relay.
  2. Contact system: it is also known as actuation mechanism. The contract system is assembled by different types of contact springs or contact chips in an insulated way to decide conducting part of the circuit.
  3. Transmission and restoration mechanism: they are also known as intermediate comparison mechanisms. The transmission mechanism is designed to transmit movement of armature to contact spring when the coil is powered on. Contact spring is moved by the contact spring which is connected to the armature or moved by the armature.
Product reviews
Small unit, but works well.
5
Richard
Avatar
5/16/2019 1:16 AM
Bought two of this small relay. Once received the units, I installed it and the connection was no problem. I use the relays to control the LED lights.  Works as expected. Great!
Was this review helpful? Yes No (0/0)
Reasonable price for 4PDT electromagnetic relay
5
Drosy
Avatar
10/31/2022 9:16 PM
Hard to find 4PDT electromagnetic relay at a great price! It works great for 24 V DC applications. I use them for converting intercom doorbells over to video doorbells for my customers, but keeping the intercom chime in use.
Was this review helpful? Yes No (0/0)