Door Limit Switch, 24VDC, 1NO+1NC, IP67

$195.55
Precision 24VDC door limit switches with 1NO+1NC contacts in PA66 flame retardant housing with green indicator light, rated at 1mA, protection class IP67, long life of up to one million mechanical operations, and a wide range of operating key options. The door limit switch is suitable for various safety and different door limit switch applications.
SKU: ATO-LS-DLS1
*
Free Shipping
Delivery date: 6-12 days

The safety door limit switch has a 24VDC voltage rating and a 1NO+1NC contact configuration. Its green indicator current is only 1mA to ensure low power operation. The solenoid has a rated operating voltage of DC24V, an initial current of 200mA, a power of 4.8W, and an insulation class of Class B (130℃). The shell material is PA66 flame retardant material, protection grade IP67, mechanical life over 1 million times, electrical life over 150,000 times. The rated insulation voltage is 300V for AC-15 and DC-13 categories, and can withstand a maximum short circuit current of 1000A. This safety limit switch can be used in an environment with humidity lower than 85%Rh. It is easy to operate and suitable for various industrial environments.

Specification

ModelATO-DX-W2
Rated Voltage24VDC
Indicator Lamp Rated Current1mA
Indicator Light Source ColorGreen
Solenoid Rated Working VoltageDC24V±10%
Solenoid Rated Current200mA (initial value)
Solenoid Rated Power4.8W
Solenoid Insulation RatingClass B (130℃)
Housing MaterialPA66 flame retardant
Conduit Port SizeM20
Contact MaterialSilver Alloy Plated
Protection ClassIP67
Operating KeyK1/K2/K3/K4 (optional)
Service LifeMechanical more than 1 million times
Electrical more than 150,000 times
Tensile Strength at Locking1300N
Rated Insulation Voltage300V
Rated Impulse Withstand Voltage2.5kV
Rated Open Thermal Current10A
Use CategoryAC-15/DC-13
Rated Working VoltageAC-15: 240V; DC-13: 30V
Rated Working CurrentAC-15: 3A; DC-13: 2.3A
Rated Limit Short Circuit Current1000A
Forced Disengagement Distance Action Force≥80N
Forced Disengagement Distance≥10mm
Allowable Operating Speed0.05-0.5m/s
Allowable Operating FrequencyMax. 20 operations/min
Ambient Temperature-20℃-60℃ without icing
Ambient HumidityBelow 85%Rh
Weight≤1000g

Note: If you need to match the key with the unlocking parts, and the individual details of the key installation please click on the PDF document to view.

Detail

Door limit switch details

The safety limit switch is compact and lightweight, easy to install, with a variety of contact configurations, a locking function is the lowest cost solution, and a variety of operating keys are available for a wide range of applications as mounting options on protective doors.

Size (unit:mm)

Door limit switch size

Connection

Door limit switch connections

Applications

Door limit switch applications

Tips: Installing the door limit switch correctly

  1. Select the Location: Determine where the door will be when it is fully closed and install the limit switch there. Ensure that the switch can be fully depressed by the door.
  2. Fixed Installation: Securely fix the limit switch to the door frame using screws or adhesive to ensure it is stable and will not come loose.
  3. Commissioning and Testing: After installation, open and close the door several times to ensure that the limit switch can be accurately triggered and restored.
  4. Wiring Connection: Correctly connect the wires of the limit switch according to the circuit diagram provided by the manufacturer, make sure the wiring is firm and avoid short circuit.
  5. Safety Protection: When installing and wiring, make sure to cut off the power supply to avoid the risk of electric shock. These tips can help you install the door limit switch better and ensure its stable and reliable operation.

VFD Emergency Stop with Limit Switches

In this video, you will learn about the setup and operation of emergency stopping a motor by using limit switches and a variable frequency drive (VFD). By combining the limit switches of the emergency stop function with the VFD GK3000, a strong safety measure can be established that can quickly stop the motor operation in an emergency.

Automatic Material Trolley Control with Limit Switch

In this video, the method of applying limit switches to automatic material trolley control is demonstrated.

Roller Limit Switch NO NC Contact Wiring and Detection

In this video, the roller limit switch NO NC contact wiring and detection operation are shown.

Product reviews
Useful door limit switch
5
Perth
Avatar
4/15/2025 1:43 AM
I used this door limit switch in the automatic door control system, mainly used to detect the opening and closing status of the door and control the stop position of the motor. The delivery speed was very fast, the appearance and workmanship were also very solid, the wiring terminals were clear and clear, and the installation was very smooth.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The safety door limit switch has a 24VDC voltage rating and a 1NO+1NC contact configuration. Its green indicator current is only 1mA to ensure low power operation. The solenoid has a rated operating voltage of DC24V, an initial current of 200mA, a power of 4.8W, and an insulation class of Class B (130℃). The shell material is PA66 flame retardant material, protection grade IP67, mechanical life over 1 million times, electrical life over 150,000 times. The rated insulation voltage is 300V for AC-15 and DC-13 categories, and can withstand a maximum short circuit current of 1000A. This safety limit switch can be used in an environment with humidity lower than 85%Rh. It is easy to operate and suitable for various industrial environments.

Specification

ModelATO-DX-W2
Rated Voltage24VDC
Indicator Lamp Rated Current1mA
Indicator Light Source ColorGreen
Solenoid Rated Working VoltageDC24V±10%
Solenoid Rated Current200mA (initial value)
Solenoid Rated Power4.8W
Solenoid Insulation RatingClass B (130℃)
Housing MaterialPA66 flame retardant
Conduit Port SizeM20
Contact MaterialSilver Alloy Plated
Protection ClassIP67
Operating KeyK1/K2/K3/K4 (optional)
Service LifeMechanical more than 1 million times
Electrical more than 150,000 times
Tensile Strength at Locking1300N
Rated Insulation Voltage300V
Rated Impulse Withstand Voltage2.5kV
Rated Open Thermal Current10A
Use CategoryAC-15/DC-13
Rated Working VoltageAC-15: 240V; DC-13: 30V
Rated Working CurrentAC-15: 3A; DC-13: 2.3A
Rated Limit Short Circuit Current1000A
Forced Disengagement Distance Action Force≥80N
Forced Disengagement Distance≥10mm
Allowable Operating Speed0.05-0.5m/s
Allowable Operating FrequencyMax. 20 operations/min
Ambient Temperature-20℃-60℃ without icing
Ambient HumidityBelow 85%Rh
Weight≤1000g

Note: If you need to match the key with the unlocking parts, and the individual details of the key installation please click on the PDF document to view.

Detail

Door limit switch details

The safety limit switch is compact and lightweight, easy to install, with a variety of contact configurations, a locking function is the lowest cost solution, and a variety of operating keys are available for a wide range of applications as mounting options on protective doors.

Size (unit:mm)

Door limit switch size

Connection

Door limit switch connections

Applications

Door limit switch applications

Tips: Installing the door limit switch correctly

  1. Select the Location: Determine where the door will be when it is fully closed and install the limit switch there. Ensure that the switch can be fully depressed by the door.
  2. Fixed Installation: Securely fix the limit switch to the door frame using screws or adhesive to ensure it is stable and will not come loose.
  3. Commissioning and Testing: After installation, open and close the door several times to ensure that the limit switch can be accurately triggered and restored.
  4. Wiring Connection: Correctly connect the wires of the limit switch according to the circuit diagram provided by the manufacturer, make sure the wiring is firm and avoid short circuit.
  5. Safety Protection: When installing and wiring, make sure to cut off the power supply to avoid the risk of electric shock. These tips can help you install the door limit switch better and ensure its stable and reliable operation.
Product reviews
Useful door limit switch
5
Perth
Avatar
4/15/2025 1:43 AM
I used this door limit switch in the automatic door control system, mainly used to detect the opening and closing status of the door and control the stop position of the motor. The delivery speed was very fast, the appearance and workmanship were also very solid, the wiring terminals were clear and clear, and the installation was very smooth.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews