Mechanical micro limit switches are highly suitable for use in mechanical, robotic, and automation systems, providing precise control and reliable operation. It operates reliably within an ambient temperature range of -25℃ to +85℃.
Features
- Industrial micro limit switch adopts a compact design, saving installation space, improving efficiency and extending service life.
- The open terminal design makes wiring more convenient.
- Its protection level reaches IP65, and the dustproof, waterproof and oil-proof structure ensures reliable operation even in harsh environments.
- The dual-circuit design of the micro limit switch improves the reliability and safety of electrical connections.
- Its aluminum alloy body and plastic shell provide high mechanical strength.
- Micro limit switches are widely used in handling machinery, machine tools and automation systems.
- The micro limit switch has CE and CCC certifications and meets international quality and safety standards.
Specification
| Model | ATO-LZ8 | |
| Rating | 5A 250VAC 0.3A 220VDC | |
| Initial contact resistance | 25mΩ max. | |
| Initial insulation resistance | 100 mΩ min. (at 500VDC) | |
| Dielectric strength | Between non-consecutive terminals | 1000Vrms, 50/60Hz for 1 min |
| Between non-current carrying metal parts and each terminal | 1500Vrms, 50/60Hz for 1 min | |
| Between ground and each terminal | 1500Vrms, 50/60Hz for 1 min | |
| Shock resistance | Mechanical durable | 1000m/s2 max. |
| Malfunction | 300m/s2 max. | |
| Vibration resistance | 10-55Hz, 1.5mm double amplitude | |
| Operating life | Mechanical life | 1,000,000 times min. |
| Electrical life | 200,000 times min. | |
| Ambient temperature | -25℃ to +85℃ | |
| Ambient humidity | 95%RH max. | |
| Operating frequency | Mechanical | 120 times/min |
| Electrical | 30 times/min | |
| Operating speed | 5mm-0.5m/s | |
| Protection degree | IP65 | |
Actuator Operating Characteristic
| Model | LZ8104 (Plastic roller lever) | Model | LZ8112 (Roller plunger) |
| O.F. max. | 750g (7.35N) | O.F. max. | 900g (8.82N) |
| R.F. min. | 100g (0.98N) | R.F. min. | 150g (1.47N) |
| P.T. max. | 20° | P.T. max. | 1.5mm |
| O.T. min. | 50° | O.T. min. | 4.0mm |
| M.D. max. | 10° | M.D. max. | 1.0mm |
| --- | --- | O.P. | 37±0.8mm |
| Model | LZ8167 (Coil spring rod) | Model | LZ8169 (Coil spring wire) |
| O.F. max. | 150g (1.47N) | O.F. max. | 150g |
| P.T. max. | 30mm | P.T. max. | 30mm |
OF: Operating Force
RF: Release Force
PT: Pre-Travel
OT: Over Travel
MD: Movement Differential
OP: Operating Position
FP: Free Position
Contact Form

Actuators
LZ8104 (Plastic roller lever) |
LZ8112 (Roller plunger) |
LZ8167 (Coil spring rod) |
LZ8169 (Coil spring wire) |
Tips: Wiring steps of micro limit switch
- Loosen the cover screws and remove the cover.
- Crossing the lead wire through rubber connector on the cover.
- Loosen the switch terminal screws and insert terminals on lead wire side into the right switch terminals and fasten the terminal screws.
- Installing the rubber connector into the cover and then install the cover. Make sure the rubber sealing strip around the cover on the right position.
- Fasten the cover screws.
Only registered users can write reviews