Digital Temperature Sensor with transmitter, Pt100, 2 Wire

$173.85
RTD sensor with digital meter can directly display high-precision real-time temperature. It converts temperature to 4-20mA standard signal proportional to the electrical signals of thermistor, and outputs to display instrument or DCS system in control room. Built-in small transmitter adopts silicone rubber seal structure, good anti-interference ability, shock and humidity, apply to harsh environments. Measuring temperature range -200~+420 ℃.
SKU: ATO-RTD-D2W
*
*
*
Free Shipping
Delivery date: 6-12 days

RTD temperature sensor can directly provide accurate input signal of temperature changes for display instruments, recording instruments, signal conditioners, scanister and computer.

Specification

1. RTD temperature range and accuracy chart

Type of sensing elementMeasuring rangeAllowable deviation Δt
Pt100-200~420℃Class B (-200~800℃) Permissible deviation ±(0.30+0.005|t|)
Class A (-200~650℃) Permissible deviation ±(0.15+0.002|t|)
Cu50-100~150℃-50~100℃ Permissible deviation ±(0.30+6.0*10-3t)

Note: t is the actual measuring temperature absolute value of the temperature sensing element.
2. Transmitter parameter chart

InputPlatinum thermistor: PT100, PT1000
Output4-20mA
Intrinsic error±0.2%, ±0.5%
Transmission modeTwo wire
Supply voltageDC 12~35V, rated voltage DC 24V
Load resistance0~600Ω (DC 24V), rated load 250Ω
Temperature influence≤0.05/1℃
Working environmentTemperature: -25~+80℃, humidity: 5%~95%, mechanical vibration: f≤55Hz, amplitude<0.15mm
Display3 1/2digital display or LCD display, temperature unit is degree centigrade (℃).


Feature

  • Wide Range of Applications: Digital temperature sensor with transmitter can directly measure the temperature of liquid, steam and gas medium in the range of -200~+420°℃ in various industrial processes, and convert the temperature into a 4-20mA unified output signal proportional to the electrical signal of the thermal resistor. It can be widely used in metallurgy, petroleum, chemical industry, electricity, light industry, textile, food and other fields.
  • Anti-interference: The transmitter component of the digital RTD sensor is miniaturized and can be installed in the junction box of the thermal resistor to become an integrated temperature transmitter. As an integrated temperature transmitter, it directly outputs 4~20mA signals in the industrial field, which improves the anti-interference ability of the signal during long-distance transmission.
  • Corrosion Resistance: RTD sensor with digital meter has high accuracy, low power consumption, wide operating environment temperature range, and stable and reliable operation. Moreover, due to the use of silicone rubber sealing structure, it is shock-resistant and moisture-resistant, and is suitable for use in harsh field environments.
  • Easy to Use: It can directly display the real-time temperature on site with high precision, and directly observe the temperature change of the measured medium. At the same time, it can output a standard 4-20mA current signal to the display instrument in the control room or the DCS system to display the temperature.

Dimension (Unit: mm)


RTD sensor meter and protection head type

Selection

Type of sensing elementMeter typeInstalling formMode of connectionThermowell diameterThermowell total length
T4: Pt100;
T6: Pt1000
P0: No meter;
P2: Meter with digital display (unit: ℃);
P4: Intelligent meter with digital display (unit: ℃)
I1: No fixed device;
I2: Fixed card sets of thread joint (thread M27*2mm);
I3: Movable card sets of thread joint (thread M27*2mm);
I4: Fixed card sets of flange (flang DN 15mm);
I6: Taper thermowell and fixing thread (thread M27*2mm)
C3: Standard waterproof protection head;
C4: Explosion-proof protection head
D0: Φ16mm (when thermowell insertion depth≥300mm);
D1: Φ12mm (when thermowell insertion depth<300mm)
225~2150mm

Note: The sensing element is sheath RTD sensor, thermowell material is stainless steel, and circuit adopts non-isolated type. When ordering products, write the thermowell insertion depth l and the corresponding temperature range for output 4~20mA signal you need.

Application

Application of digital temperature sensor with transmitter pt100 2wire

Tips: Troubleshooting of Pt100 RTD sensor

  1. Fault: Instrument shows negative value.
    Possible cause: Wrong connection between display instrument and Pt100 RTD sensor, or short circuit of Pt100 RTD sensor.
    Processing method: Correct the connection, find out short circuit position and strengthen insulation.
  2. Fault: Instrument shows that the indicated value of Pt100 RTD sensor is lower than the actual value or the indicating value is unstable.
    Possible cause: There are metal chips, dust, dirt among wiring terminal and Pt100 RTD sensor short circuit.
    Processing method: Remove metal chips, clean dust and water drops, find out short circuit position and strengthen insulation.
  3. Fault: Instrument displays infinity.
    Possible reasons: Pt100 RTD sensor or lead wire short circuit, or connection terminal loosening, etc.
    Processing method: Change the resistance body, or welding and tighten the thread screw.
  4. Fault: Relation between Pt100 RTD sensor resistance value and temperature has changed.
    Possible cause: Resistance wire of Pt100 RTD sensor become corrosive and degenerative.
    Processing method: Replace resistance wire of Pt100 RTD sensor.

In this video, ATO will show you how to use RTD PT100 with transmitter and temperature controller to measure temperature.

Fixed Installation Dimension Drawing

Design serial number1
Structure diagramThermocouple RDT sensor dimension
NameFixed thread
SizeM27*2 (default), G3/4", M33*2, G1", other
Protection tubeDiameterφ12mm, φ16mm, other
Texture of material1Cr18Ni9Ti, 2Cr25Ni20, other
Withstand voltage≤10MPa
Design serial number2
Structure diagramThermocouple RDT sensor dimension
NameMovable flange
Protection tubeDiameterφ12mm, φ16mm, other
Texture of material1Cr18Ni9Ti, 2Cr25Ni20, other
Withstand voltageAtmospheric pressure
Design serial number3
Structure diagramThermocouple RDT sensor dimension
NameFixed flange
SizeDN15mm (default)D095mmDN20mm105mm
D165mm75mm
D245mm55mm
φn4-φ14mm4-φ14mm
DN25mmD0115mmDN32mm140mm
D185mm100mm
D265mm78mm
φn4-φ14mm4-φ18mm
DN40mmD0150mmDN50mm165mm
D1110mm125mm
D285mm100mm
φn4-φ18mm4-φ18mm
H12mm
Protection tubeDiameterφ12mm, φ16mm, other
Texture of material1Cr18Ni9Ti, 2Cr25Ni20, other
Withstand voltage≤6.4MPa
Design serial number4
Structure diagramThermocouple RDT sensor dimension
NameConical fixed thread
SizeM27*2 (default), M33*2, G1", other
Protection tubeDiameterφ12mm, φ16mm, other
Texture of material1Cr18Ni9Ti, 2Cr25Ni20, other
Withstand voltage≥30MPa
Product reviews
Good 2-wire digital temperature sensor
5
Rural
Avatar
3/2/2021 6:24 PM
Before shipping, can you send me some photos of this Pt100 digital temperature sensor?
Was this review helpful? Yes No (0/0)
ATO Responded
We hope to get this order. Yes, we will fully support you. And will send you the photos of the Pt100 digital temperature sensor before shipment.
Can the digital temperature sensor be customized?
5
Michelle
Avatar
4/22/2021 1:11 AM
I'm looking a PT 100, class B, RTD sensor probe with protection head, about 60 inches long shealth, fixing thread, but wtihout thermowell, just sensor probe with head. Can you customize based on our specs?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can. Please inform about your specs (sheath length, diameter, 2 or 3 wires etc.), so can quote accordingly.
Product requirements
5
Candace
Avatar
6/9/2026 8:35 PM
We are designing a glove box and require an integrated K-type thermocouple and transmitter assembly, to be mounted inside a secondary protective glove box via a KF flange.
Was this review helpful? Yes No (0/0)
ATO Responded
We recommend our digital temperature sensor (with transmitter), Pt100, DN15 flange mount, 4-20mA output, product number: ATO-RTD-D2W. Please confirm if it meets your requirements.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

RTD temperature sensor can directly provide accurate input signal of temperature changes for display instruments, recording instruments, signal conditioners, scanister and computer.

Specification

1. RTD temperature range and accuracy chart

Type of sensing elementMeasuring rangeAllowable deviation Δt
Pt100-200~420℃Class B (-200~800℃) Permissible deviation ±(0.30+0.005|t|)
Class A (-200~650℃) Permissible deviation ±(0.15+0.002|t|)
Cu50-100~150℃-50~100℃ Permissible deviation ±(0.30+6.0*10-3t)

Note: t is the actual measuring temperature absolute value of the temperature sensing element.
2. Transmitter parameter chart

InputPlatinum thermistor: PT100, PT1000
Output4-20mA
Intrinsic error±0.2%, ±0.5%
Transmission modeTwo wire
Supply voltageDC 12~35V, rated voltage DC 24V
Load resistance0~600Ω (DC 24V), rated load 250Ω
Temperature influence≤0.05/1℃
Working environmentTemperature: -25~+80℃, humidity: 5%~95%, mechanical vibration: f≤55Hz, amplitude<0.15mm
Display3 1/2digital display or LCD display, temperature unit is degree centigrade (℃).


Feature

  • Wide Range of Applications: Digital temperature sensor with transmitter can directly measure the temperature of liquid, steam and gas medium in the range of -200~+420°℃ in various industrial processes, and convert the temperature into a 4-20mA unified output signal proportional to the electrical signal of the thermal resistor. It can be widely used in metallurgy, petroleum, chemical industry, electricity, light industry, textile, food and other fields.
  • Anti-interference: The transmitter component of the digital RTD sensor is miniaturized and can be installed in the junction box of the thermal resistor to become an integrated temperature transmitter. As an integrated temperature transmitter, it directly outputs 4~20mA signals in the industrial field, which improves the anti-interference ability of the signal during long-distance transmission.
  • Corrosion Resistance: RTD sensor with digital meter has high accuracy, low power consumption, wide operating environment temperature range, and stable and reliable operation. Moreover, due to the use of silicone rubber sealing structure, it is shock-resistant and moisture-resistant, and is suitable for use in harsh field environments.
  • Easy to Use: It can directly display the real-time temperature on site with high precision, and directly observe the temperature change of the measured medium. At the same time, it can output a standard 4-20mA current signal to the display instrument in the control room or the DCS system to display the temperature.

Dimension (Unit: mm)


RTD sensor meter and protection head type

Selection

Type of sensing elementMeter typeInstalling formMode of connectionThermowell diameterThermowell total length
T4: Pt100;
T6: Pt1000
P0: No meter;
P2: Meter with digital display (unit: ℃);
P4: Intelligent meter with digital display (unit: ℃)
I1: No fixed device;
I2: Fixed card sets of thread joint (thread M27*2mm);
I3: Movable card sets of thread joint (thread M27*2mm);
I4: Fixed card sets of flange (flang DN 15mm);
I6: Taper thermowell and fixing thread (thread M27*2mm)
C3: Standard waterproof protection head;
C4: Explosion-proof protection head
D0: Φ16mm (when thermowell insertion depth≥300mm);
D1: Φ12mm (when thermowell insertion depth<300mm)
225~2150mm

Note: The sensing element is sheath RTD sensor, thermowell material is stainless steel, and circuit adopts non-isolated type. When ordering products, write the thermowell insertion depth l and the corresponding temperature range for output 4~20mA signal you need.

Application

Application of digital temperature sensor with transmitter pt100 2wire

Tips: Troubleshooting of Pt100 RTD sensor

  1. Fault: Instrument shows negative value.
    Possible cause: Wrong connection between display instrument and Pt100 RTD sensor, or short circuit of Pt100 RTD sensor.
    Processing method: Correct the connection, find out short circuit position and strengthen insulation.
  2. Fault: Instrument shows that the indicated value of Pt100 RTD sensor is lower than the actual value or the indicating value is unstable.
    Possible cause: There are metal chips, dust, dirt among wiring terminal and Pt100 RTD sensor short circuit.
    Processing method: Remove metal chips, clean dust and water drops, find out short circuit position and strengthen insulation.
  3. Fault: Instrument displays infinity.
    Possible reasons: Pt100 RTD sensor or lead wire short circuit, or connection terminal loosening, etc.
    Processing method: Change the resistance body, or welding and tighten the thread screw.
  4. Fault: Relation between Pt100 RTD sensor resistance value and temperature has changed.
    Possible cause: Resistance wire of Pt100 RTD sensor become corrosive and degenerative.
    Processing method: Replace resistance wire of Pt100 RTD sensor.
Product reviews
Good 2-wire digital temperature sensor
5
Rural
Avatar
3/2/2021 6:24 PM
Before shipping, can you send me some photos of this Pt100 digital temperature sensor?
Was this review helpful? Yes No (0/0)
ATO Responded
We hope to get this order. Yes, we will fully support you. And will send you the photos of the Pt100 digital temperature sensor before shipment.
Can the digital temperature sensor be customized?
5
Michelle
Avatar
4/22/2021 1:11 AM
I'm looking a PT 100, class B, RTD sensor probe with protection head, about 60 inches long shealth, fixing thread, but wtihout thermowell, just sensor probe with head. Can you customize based on our specs?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can. Please inform about your specs (sheath length, diameter, 2 or 3 wires etc.), so can quote accordingly.
Product requirements
5
Candace
Avatar
6/9/2026 8:35 PM
We are designing a glove box and require an integrated K-type thermocouple and transmitter assembly, to be mounted inside a secondary protective glove box via a KF flange.
Was this review helpful? Yes No (0/0)
ATO Responded
We recommend our digital temperature sensor (with transmitter), Pt100, DN15 flange mount, 4-20mA output, product number: ATO-RTD-D2W. Please confirm if it meets your requirements.
Only registered users can write reviews
Customers who bought this item also bought

Temp and Humidity Sensor/Transmitter, Duct/Wall Mounted, 0-10V

ATO-TAHT-FG6010
$69.83
Temperature and humidity transmitter adopts a digital temperature and humidity sensor, and converts air temperature and humidity into 0-10V standard signal. Industrial temperature and humidity transmitter has explosion-proof aluminum alloy housing, metal filter screen, wide measuring range, high measurement accuracy in high-low temperature and humidity, fast response, excellent long-term stability and anti-chemical pollution.

Water to Air Brazed Plate Heat Exchanger, 50/60 Plate

ATO-PHE-5060
$341.85
Brazed plate heat exchanger price is competitive. Maximum quantity of plates is 50 or 60 for different models, heat exchange capacity is 14kBTU/17kBTU/6.8k~34kBTU respectively. The product is non-standard, plate specific quantity can be customized. Applicable mediums include water to water, air to air, water to air, oil to water, etc.

Accurate Temperature Humidity Sensor, Stainless Steels Duct

ATO-TAHS-300ATH
$175.88
Accurate temperature and humidity sensors at low cost, with stainless steel duct construction, designed for high accuracy measurement, support RS485, 4-20mA, 0-5V and 0-10V output signals, and measurement temperature can be upgraded from -40°C to 120°C, providing stable and durable temperature and humidity monitoring solutions.