Digital Panel Meter for Displacement Sensor 4 Digit

$174.62
Single channel digital panel meter cooperate with all kinds of analog output sensor and transmitter, realize measurement, conversion, display, transmitting, record and control, zero clearing at any time.
SKU: ATO-DPM-DS4D
*
*
*
Free Shipping
Delivery date: 6-12 days

Intelligent digital panel meter has adjustment and digital filtering function. The digital display controller can be used for various sensors and transmitters, such as temperature sensor, pressure sensor, flow sensor, level sensor, displacement sensor, AC/DC current sensor and transmitter with 4-20mA/0-5V/0-10V analog output, etc.

Specification:

BasicsModelATO-DPM-DS4D-CH6
PDFDigital panel meter user manual
Dimension (W*H*L)D1: 160*80*125mm horizontal, hole size 152*76mm;
D2: 80*160*125mm vertical, hole size 76*152mm;
D3: 96*96*76mm, hole size 92*92mm;
D4: 96*48*82mm horizontal, hole size 92*45mm;
D5: 48*96*82mm vertical, hole size 92*45mm;
D6: 72*72*75mm, hole size 68*68mm;
D7: 48*48*108mm, hole size 45.5*45.5mm.
Shipping weight2 kg
Technical parametersDisplay-1999~9999
Measurement accuracy<0.5%
Measuring speed10 times/second
Display method4 digit LED display; 4 digit LED display + setting
Instrument power supply100-240VAC, 50/60Hz
Universal signal inputDC current 4-20mA, 0-20mA, 0-10mA;
DC voltage 0-5V, 1-5V;
RTD sensor: Pt100 (-200~+500℃), Cu100 (-50~+150℃), Cu50 (-50~+150℃), BA1 (-200~+650℃), BA2 (-200~+500℃), G53 (-50~+150℃);
Thermocouple: K type (-100~+1300℃), S type (0~+1700℃), R type (0~+1700℃), B type (500~1800℃), N type (-100~+1300℃), E type (-100~+800℃), J type (-100~+1100℃), T type (-100~+400℃).
*Note: DC voltage 0-10V input need to be customized and can't be a universal signal input.
AlarmAH and AL alarm (2-channel relay output)
Additional power supply (optional)P0: No power supply;
P1: DC 24V±5%, <50mA;
P2: DC 12V±5%, <50mA.
*Note: Additional power supply can provide DC power supply for other devices such as sensors.
Output signal (optional)T0: No output signal;
T1: Current output (4-20mA), (0-10mA), (0-20mA);
T2: Voltage output (0-5V), (1-5V);
T3: Voltage output (0-10V).
*Note: DC voltage 0-10V output need to be customized.

Tips: How to set digital panel meter for displacement sensor?
The parameters of digital panel meter for displacement sensors generally include the upper limit of measured value, the lower limit of the measured value, the upper limit of deviation, the lower limit of deviation, the absolute value of the deviation. For example, the upper (lower) limit of measured value is used to set the maximum (minimum) measuring range of the displacement. It is used to display the displacement value delivered to the DCS control system.

In this video, ATO will show you how to set the basic parameters of digital panel meter, and how to connect a digital panel meter and a displacement sensor to form a simple displacement measuring system.

Temperature Controller Wiring and Settings

In this video, ATO will show you how to connect a temperature controller with a thermocouple or RTD sensor, and how to set the basic parameters of the temperature controller.

Load Cell Controller Setup and Calibration

In this video, we select an S-type load cell and a 2kg standard weight to complete the setup and calibration. Finally, ATO also shows you how to set the tare value and measure the tare weight.

Product reviews
Highly recommended
5
Daniel
Avatar
3/29/2022 12:11 AM
I bought it to monitor displacement sensor. It performed exactly as expected. Very good product. The screen is very clear and easy to read. Highly recommended.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Intelligent digital panel meter has adjustment and digital filtering function. The digital display controller can be used for various sensors and transmitters, such as temperature sensor, pressure sensor, flow sensor, level sensor, displacement sensor, AC/DC current sensor and transmitter with 4-20mA/0-5V/0-10V analog output, etc.

Specification:

BasicsModelATO-DPM-DS4D-CH6
PDFDigital panel meter user manual
Dimension (W*H*L)D1: 160*80*125mm horizontal, hole size 152*76mm;
D2: 80*160*125mm vertical, hole size 76*152mm;
D3: 96*96*76mm, hole size 92*92mm;
D4: 96*48*82mm horizontal, hole size 92*45mm;
D5: 48*96*82mm vertical, hole size 92*45mm;
D6: 72*72*75mm, hole size 68*68mm;
D7: 48*48*108mm, hole size 45.5*45.5mm.
Shipping weight2 kg
Technical parametersDisplay-1999~9999
Measurement accuracy<0.5%
Measuring speed10 times/second
Display method4 digit LED display; 4 digit LED display + setting
Instrument power supply100-240VAC, 50/60Hz
Universal signal inputDC current 4-20mA, 0-20mA, 0-10mA;
DC voltage 0-5V, 1-5V;
RTD sensor: Pt100 (-200~+500℃), Cu100 (-50~+150℃), Cu50 (-50~+150℃), BA1 (-200~+650℃), BA2 (-200~+500℃), G53 (-50~+150℃);
Thermocouple: K type (-100~+1300℃), S type (0~+1700℃), R type (0~+1700℃), B type (500~1800℃), N type (-100~+1300℃), E type (-100~+800℃), J type (-100~+1100℃), T type (-100~+400℃).
*Note: DC voltage 0-10V input need to be customized and can't be a universal signal input.
AlarmAH and AL alarm (2-channel relay output)
Additional power supply (optional)P0: No power supply;
P1: DC 24V±5%, <50mA;
P2: DC 12V±5%, <50mA.
*Note: Additional power supply can provide DC power supply for other devices such as sensors.
Output signal (optional)T0: No output signal;
T1: Current output (4-20mA), (0-10mA), (0-20mA);
T2: Voltage output (0-5V), (1-5V);
T3: Voltage output (0-10V).
*Note: DC voltage 0-10V output need to be customized.

Tips: How to set digital panel meter for displacement sensor?
The parameters of digital panel meter for displacement sensors generally include the upper limit of measured value, the lower limit of the measured value, the upper limit of deviation, the lower limit of deviation, the absolute value of the deviation. For example, the upper (lower) limit of measured value is used to set the maximum (minimum) measuring range of the displacement. It is used to display the displacement value delivered to the DCS control system.

Product reviews
Highly recommended
5
Daniel
Avatar
3/29/2022 12:11 AM
I bought it to monitor displacement sensor. It performed exactly as expected. Very good product. The screen is very clear and easy to read. Highly recommended.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

Tension Load Cell for Crane, 2 ton/5 ton/30 ton/50 ton to 70 ton

ATO-LC-T01
$153.85
2 ton to 70 ton/100 ton load cell can bear both tension and compression, with high accuracy, strong overload capacity and protection class IP67. Wire ropes can be directly tied to the holes at both ends of the load cell. Tension load cell can be applied for crane, hook scale, port/terminal lifting equipment measurement and control.

Single Point Load Cell, 300g/1kg/3kg/ 10kg/60kg/100kg/200kg to 500kg

ATO-LC-SP01
$79.89
Single point load cell is widely used for weighing scale or pricing scale. Single point load cell is suited to use in flat and low space, with parallel beam structure, good stability, good output symmetry, high accuracy, low temperature drift and overload protection.

Load Cell Transmitter, Output 0-5V/0-10V/4-20mA

ATO-LCTR-OA
$81.27
Load cell transmitter is made of aluminum alloy, output standard signal 0-5V/0-10V/4-20mA, has linear compensation, humidity compensation, external zero debugging, external span debugging, input overload protection and output short circuit protection functions.

Reaction Torque Sensor, Flange to Square Drive, 2/10/30/50/100/200 Nm

ATO-TQS-S03
$134.92
Torque sensor is a strain gauge sensor for static torque measurement or torque wrench calibration. It can measure both forward and reverse torque. Static torque sensor has one end of flange and the other end of square drive. Reaction torque sensors have a capacity range of 2/10/30/50/100/200 Nm.

Micro Reaction Torque Sensor for Static Torque, 0.5-150 Nm

ATO-TQS-S04
$175.93
Micro torque sensor is a reaction torque sensor for static torque measurement. Torque sensor is made of aluminium alloy, 150%FS safety overload, -20°C~+80°C operating temperature, low price. Reaction torque transducers have a capacity range from 0.5 Nm ~ 150 Nm and can measure both forward and reverse torque.