Current Monitoring Relay, Over/ Under Current, 1A/2A/5A/8A/16A, AC/DC24V-240V

$61.24
The current monitoring relay has 1 SPDT switch, suitable for rated voltage AC/DC 24V-240V range, with undercurrent/over current protection. The current limiting relay has an LED indicator to display the operating status, mainly used to monitor whether the current in the circuit exceeds the preset value and take corresponding measures when it exceeds the preset value. It has a built-in isolated current transformer, and an external current transformer can be connected to expand the monitoring current range. In addition, it can be flexibly adjusted through a potentiometer, with 6 current specifications to choose from.
SKU: ATO-MR-GRI8
*
*
Free Shipping
Delivery date: 6-12 days

The current monitoring relay is a protection device in the power system, which can monitor the current in the circuit in real-time, such as monitoring the heating conditions in the track switch, heating cables, and the consumption of single-phase motors, to prevent circuit overload, short circuit, and other faults from causing equipment damage or fire and other safety accidents. It is compact, only 18mm wide, and easy to install on the 35mm rail.

Feature

  • Adjustable delay 0.1-10 s to eliminate short current peaks, to avoid starting current of motor loads.
  • Flexible adjustment by potentiometer, choice of 6 ranges: AC 0.05-0.5A; AC 0.1-1A; AC 0.2-2A; AC 0.5-5A; AC 0.8-8A; AC 1.6-16A-Power up delay.
  • Possible to use it for current scanning from the current transformer.
  • Universal supply AC/DC 24V-240V.
  • Relay status is indicated by LED.
  • 1-MoDULE, DIN rail mounting.

Technical Parameters

ModelATO-GRI8-01ATO-GRI8-02
FunctionOver CurrentUnder Current
Supply TerminalsA1-A2
Rated Supply VoltageAC/DC 24V-240V
Rated Supply Frequency50/60Hz, 0
BurdenMax 25VA
Supply Voltage Tolerance-15%, +10%
Current Range (Optional)0.5A (0.05~0.5A); 1A (0.1~1A); 2A (0.2~2A); 5A (0.5~5A); 8A (0.8~8A); 16A (1.6~16A)
Current FrequencyAC 50Hz
Max. operating Current1A, 2A, 5A, 8A, 12A, 22A
Current AdjustmentPotentiometer
Time DelayAdjustable 0.1-10 s
Power Up DelayAdjustable 0.1-10 s
Supply IndicationGreen LED
Setting Accuracy10%
Repeat Accuracy<1%
Temperature Dependence<0.1%/°C
Limit Values Tolerance5% (10% for 0.05 - 0.5A range)
Hysteresis5%
Temperature Coefficient0.05%/°C, at=20°C (0.05%°F, at=68°F)
Output1×SPDT
Current Rating10A/AC1
Switching Voltage250VAC/ 24VDC
Min. breaking Capacity DC500mW
Output IndicationRed LED
Mechanical Life1×107
Electrical Life (AC1)1×105
Operating Temperature-20°C to +55°C (-4°F to 131°F)
Storage Temperature-35℃ to +75°C (-22°F to 158°F)
Installation35mm rail installation
Mounting/ DIN railDin rail EN/ IEC 60715
Protection DegreelP40 for front panel/ IP20 terminals
Operating PositionAny
Overvoltage CathegoryIII.
Pollution Degree2
Max. cable Size (mm2 )Solid wire max. 1×2.5 or 2×1.5/ with sleeve max. 1×2.5 (AwG 12)
Dimensions90mm×18mm×64mm
Weight64g
StandardsEN 60255-1


Wiring Diagram

Current monitoring relay witing samll

Current monitoring relay witing 2

Panel Diagram

Current monitoring relay panel diagram GRI8

Function Diagram

  • GRI8-01

Current monitoring relay function GRI801

  • GRI8-02

Current monitoring relay function GRI802

Dimensions (mm)

Current monitoring relay dimension

Tips: How to choose a suitable current monitoring relay?

The first is the electrical parameters, including rated voltage, rated current, action time release time, etc. These parameters must meet the needs of the actual application scenario. It is best to be able to combine the working environment, and environmental factors such as temperature, humidity, vibration, etc. must be considered to select the size that meets the installation space requirements.

The second is the relay type, which requires selecting the appropriate relay type and function according to the load type and control requirements, such as AC relay, DC relay, solid-state relay, etc. In addition, some additional functions cannot be ignored. Some relays may have additional functions, such as fault indication, remote control, communication interface, etc.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The current monitoring relay is a protection device in the power system, which can monitor the current in the circuit in real-time, such as monitoring the heating conditions in the track switch, heating cables, and the consumption of single-phase motors, to prevent circuit overload, short circuit, and other faults from causing equipment damage or fire and other safety accidents. It is compact, only 18mm wide, and easy to install on the 35mm rail.

Feature

  • Adjustable delay 0.1-10 s to eliminate short current peaks, to avoid starting current of motor loads.
  • Flexible adjustment by potentiometer, choice of 6 ranges: AC 0.05-0.5A; AC 0.1-1A; AC 0.2-2A; AC 0.5-5A; AC 0.8-8A; AC 1.6-16A-Power up delay.
  • Possible to use it for current scanning from the current transformer.
  • Universal supply AC/DC 24V-240V.
  • Relay status is indicated by LED.
  • 1-MoDULE, DIN rail mounting.

Technical Parameters

ModelATO-GRI8-01ATO-GRI8-02
FunctionOver CurrentUnder Current
Supply TerminalsA1-A2
Rated Supply VoltageAC/DC 24V-240V
Rated Supply Frequency50/60Hz, 0
BurdenMax 25VA
Supply Voltage Tolerance-15%, +10%
Current Range (Optional)0.5A (0.05~0.5A); 1A (0.1~1A); 2A (0.2~2A); 5A (0.5~5A); 8A (0.8~8A); 16A (1.6~16A)
Current FrequencyAC 50Hz
Max. operating Current1A, 2A, 5A, 8A, 12A, 22A
Current AdjustmentPotentiometer
Time DelayAdjustable 0.1-10 s
Power Up DelayAdjustable 0.1-10 s
Supply IndicationGreen LED
Setting Accuracy10%
Repeat Accuracy<1%
Temperature Dependence<0.1%/°C
Limit Values Tolerance5% (10% for 0.05 - 0.5A range)
Hysteresis5%
Temperature Coefficient0.05%/°C, at=20°C (0.05%°F, at=68°F)
Output1×SPDT
Current Rating10A/AC1
Switching Voltage250VAC/ 24VDC
Min. breaking Capacity DC500mW
Output IndicationRed LED
Mechanical Life1×107
Electrical Life (AC1)1×105
Operating Temperature-20°C to +55°C (-4°F to 131°F)
Storage Temperature-35℃ to +75°C (-22°F to 158°F)
Installation35mm rail installation
Mounting/ DIN railDin rail EN/ IEC 60715
Protection DegreelP40 for front panel/ IP20 terminals
Operating PositionAny
Overvoltage CathegoryIII.
Pollution Degree2
Max. cable Size (mm2 )Solid wire max. 1×2.5 or 2×1.5/ with sleeve max. 1×2.5 (AwG 12)
Dimensions90mm×18mm×64mm
Weight64g
StandardsEN 60255-1


Wiring Diagram

Current monitoring relay witing samll

Current monitoring relay witing 2

Panel Diagram

Current monitoring relay panel diagram GRI8

Function Diagram

  • GRI8-01

Current monitoring relay function GRI801

  • GRI8-02

Current monitoring relay function GRI802

Dimensions (mm)

Current monitoring relay dimension

Tips: How to choose a suitable current monitoring relay?

The first is the electrical parameters, including rated voltage, rated current, action time release time, etc. These parameters must meet the needs of the actual application scenario. It is best to be able to combine the working environment, and environmental factors such as temperature, humidity, vibration, etc. must be considered to select the size that meets the installation space requirements.

The second is the relay type, which requires selecting the appropriate relay type and function according to the load type and control requirements, such as AC relay, DC relay, solid-state relay, etc. In addition, some additional functions cannot be ignored. Some relays may have additional functions, such as fault indication, remote control, communication interface, etc.