3 Phase Voltage Monitor Relay, 3-wire 220V-460V/4-wire 127V-265V

$68.39
The three-phase voltage monitoring relay has SPDT (2 C/O) contacts, accurate pressure measurement, and is suitable for quickly cutting off or connecting the circuit when the power supply voltage exceeds or falls below the set range for 3-wire AC 220V-460V/ 4-wire AC 127V-265V to ensure the safe and reliable operation of the power system. The 3-phase relay is equipped with LED lights to indicate the working status and is lightweight and easy to install.
SKU: ATO-MR-GRV810
*
Free Shipping
Delivery date: 6-12 days

The 3-phase voltage monitor relay has an LED indicator to indicate the working status, with a normal/ emergency power switch, which can effectively detect voltage imbalance and protect the equipment from accidents caused by the reverse operation. There are two open and two closed contacts, and the flame-retardant shell is reinforced. This three-phase relay has 8 rated voltages that are adjustable, with a wide range of applications, and can be used for field equipment, agricultural equipment, refrigerated vehicle lights, and mobile equipment connection control.

Feature

  • Controls its own supply voltage (True RMS measurement).
  • Set 8-level rated operating voltage through the knob.
  • Set the reset delay time through the knob.
  • 2C/O output.
  • Measuring frequency range: 45Hz-65Hz.
  • Voltage measurement accuracy <1%.
  • Relay status is indicated by LED.
  • 2-MODULE, DIN rail mounting.
  • Ultra-small size, only 36mm width, 35mm rail installation.

Specification

ModelATO-GRV8-10M265ATO-GRV8-10M460
FunctionMonitor L-N voltage (3-phase 4-wire system)Monitor L-L voltage (3-phase 3-wire)
Monitoring TerminalsL1-L2-L3-NL1-L2-L3
Supply TerminalsL1-L2-L3-NL1-L2-L3
Voltage Range127-132-138-220-230-240-254-265 (P-N)220-230-240-380-400-415-440-460 (P-P)
Rated Surge Withstand Voltage2.5kV
Rated Insulation Voltage500
Rated Supply Frequency45-65Hz
Measuring Range101-318V176-552V
Threshold Adjustment Voltage2%-20% of unselected
Adjustment of Asymmetry Threshold5%-15%
Hysteresis2%
Phase Failure Voltage70% of the rated voltage
Supply IndicationGreen LED
Time DelayAdjustable 0.1 s - 10 s, 10%
Measurement Error≤1%
Run-up Delay at Power-upAdjustable 0.1 s - 10 s, 10%
Konb Setting Accuracy10% of scale value
Reset TimeAdjustable 0.1 s - 10 s, 10%
Temperature Coefficient0.05%°C, at=20°C (0.05%°F, at=68°F)
Output2×SPDT
Current Rating8A/AC1
Switching Voltage250VAC/ 24VDC
Min. breaking Capacity DC500MW
Output IndicationRed LED
Mechanical Life1×107
Electrical Life (AC1)1×105
Operating Temperature-20°℃ to +55℃ (-4°F to 131°F)
Storage Temperature-35℃ to +75℃ (-22°F to 158°F)
Mounting/ DIN railDin rail EN/ IEC 60715
Protection DegreelP40 for front panel/ IP20 terminals
Installation35mm rail installation
Operating PositionAny
Overvoltage CathegoryIII.
Pollution Degree2
Max. cable Size (mm2)Solid wire max.1×2.5 or 2×1.5/ with sleeve max.1×2.5 (AWG 12)
Dimensions90mm×36mm×64mm
Weight100g
StandardsEN 60255-1, lEC60947-5-1


Wiring Diagram

3-phase voltage monitor relay phase wiring

Panel Diagram

3-phase voltage monitor relay phase panel

Function Diagram

  • Phase failure and phase sequence function diagram

3-phase voltage monitor relay phase failure and sequence

  • Asymmetry function diagram

3-phase voltage monitor relay phase asymmetry function

To: Overvoltage threshold tripping delay.
Tu: Undervoltage threshold tripping delay.
Ta: Asymmetry threshold tripping delay.
Tr: Power-up delay.

  • Overvoltage and undervoltage function diagram

3-phase voltage monitor relay phase overvoltage and undervoltage

Dimensions (mm)

3-phase voltage monitor relay dimension mm

Tips: Maintenance of 3-Phase voltage monitor relay

Use a soft brush or air blow gun to remove dust from the outside and inside of the relay and maintain a dry and clean environment.

Tighten the screws and regularly replace aging parts such as worn contacts or coils to keep the relay in normal working condition. Regularly check the contact point pressure and arc marks of the relay to ensure that the contact point pressure is appropriate and there is no abnormal wear or corrosion.

Ensure that the power supply voltage is stable to prevent the relay from bearing a current load exceeding the rated capacity to prevent overload damage. The working environment temperature should be appropriate. If it exceeds the specified temperature range, heat dissipation measures need to be taken.

3-Phase Monitoring Relay Phase Failure & Phase Sequence Testing

In this video, we will give you a test of ATO 3-phase monitoring relay on phase failure and phase sequence, and the relay does the job at such these cases to protect the motor. In addition, this multi-purpose monitoring relay has other monitoring functions such as undervoltage, overvoltage, voltage unbalance, timer & counter.

Working Principles 3-Phase Monitoring Relay 

3-phase Monitoring Relay Phase Failure and Sequence Test

In this video, the phase failure and sequence test of the 3-phase monitoring relay is introduced.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Useful 3 Phase Voltage Monitor Relay
5
Lorraine
Avatar
6/6/2024 3:46 AM
I referred to the data on many pages before deciding to buy this three-phase voltage monitoring relay, because the original electrical wiring in the house was installed many years ago when I moved in, and it is not easy to change it over time. However, because I recently purchased a solar panel, I decided to install a monitor for safety reasons. This 3-phase voltage relay can monitor the AC voltage before connecting to the grid, ensure voltage stability during the switching process, and prevent equipment damage or safety accidents due to voltage fluctuations. The high quality of the relay saved me a lot of trouble later.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The 3-phase voltage monitor relay has an LED indicator to indicate the working status, with a normal/ emergency power switch, which can effectively detect voltage imbalance and protect the equipment from accidents caused by the reverse operation. There are two open and two closed contacts, and the flame-retardant shell is reinforced. This three-phase relay has 8 rated voltages that are adjustable, with a wide range of applications, and can be used for field equipment, agricultural equipment, refrigerated vehicle lights, and mobile equipment connection control.

Feature

  • Controls its own supply voltage (True RMS measurement).
  • Set 8-level rated operating voltage through the knob.
  • Set the reset delay time through the knob.
  • 2C/O output.
  • Measuring frequency range: 45Hz-65Hz.
  • Voltage measurement accuracy <1%.
  • Relay status is indicated by LED.
  • 2-MODULE, DIN rail mounting.
  • Ultra-small size, only 36mm width, 35mm rail installation.

Specification

ModelATO-GRV8-10M265ATO-GRV8-10M460
FunctionMonitor L-N voltage (3-phase 4-wire system)Monitor L-L voltage (3-phase 3-wire)
Monitoring TerminalsL1-L2-L3-NL1-L2-L3
Supply TerminalsL1-L2-L3-NL1-L2-L3
Voltage Range127-132-138-220-230-240-254-265 (P-N)220-230-240-380-400-415-440-460 (P-P)
Rated Surge Withstand Voltage2.5kV
Rated Insulation Voltage500
Rated Supply Frequency45-65Hz
Measuring Range101-318V176-552V
Threshold Adjustment Voltage2%-20% of unselected
Adjustment of Asymmetry Threshold5%-15%
Hysteresis2%
Phase Failure Voltage70% of the rated voltage
Supply IndicationGreen LED
Time DelayAdjustable 0.1 s - 10 s, 10%
Measurement Error≤1%
Run-up Delay at Power-upAdjustable 0.1 s - 10 s, 10%
Konb Setting Accuracy10% of scale value
Reset TimeAdjustable 0.1 s - 10 s, 10%
Temperature Coefficient0.05%°C, at=20°C (0.05%°F, at=68°F)
Output2×SPDT
Current Rating8A/AC1
Switching Voltage250VAC/ 24VDC
Min. breaking Capacity DC500MW
Output IndicationRed LED
Mechanical Life1×107
Electrical Life (AC1)1×105
Operating Temperature-20°℃ to +55℃ (-4°F to 131°F)
Storage Temperature-35℃ to +75℃ (-22°F to 158°F)
Mounting/ DIN railDin rail EN/ IEC 60715
Protection DegreelP40 for front panel/ IP20 terminals
Installation35mm rail installation
Operating PositionAny
Overvoltage CathegoryIII.
Pollution Degree2
Max. cable Size (mm2)Solid wire max.1×2.5 or 2×1.5/ with sleeve max.1×2.5 (AWG 12)
Dimensions90mm×36mm×64mm
Weight100g
StandardsEN 60255-1, lEC60947-5-1


Wiring Diagram

3-phase voltage monitor relay phase wiring

Panel Diagram

3-phase voltage monitor relay phase panel

Function Diagram

  • Phase failure and phase sequence function diagram

3-phase voltage monitor relay phase failure and sequence

  • Asymmetry function diagram

3-phase voltage monitor relay phase asymmetry function

To: Overvoltage threshold tripping delay.
Tu: Undervoltage threshold tripping delay.
Ta: Asymmetry threshold tripping delay.
Tr: Power-up delay.

  • Overvoltage and undervoltage function diagram

3-phase voltage monitor relay phase overvoltage and undervoltage

Dimensions (mm)

3-phase voltage monitor relay dimension mm

Tips: Maintenance of 3-Phase voltage monitor relay

Use a soft brush or air blow gun to remove dust from the outside and inside of the relay and maintain a dry and clean environment.

Tighten the screws and regularly replace aging parts such as worn contacts or coils to keep the relay in normal working condition. Regularly check the contact point pressure and arc marks of the relay to ensure that the contact point pressure is appropriate and there is no abnormal wear or corrosion.

Ensure that the power supply voltage is stable to prevent the relay from bearing a current load exceeding the rated capacity to prevent overload damage. The working environment temperature should be appropriate. If it exceeds the specified temperature range, heat dissipation measures need to be taken.

Product reviews
Useful 3 Phase Voltage Monitor Relay
5
Lorraine
Avatar
6/6/2024 3:46 AM
I referred to the data on many pages before deciding to buy this three-phase voltage monitoring relay, because the original electrical wiring in the house was installed many years ago when I moved in, and it is not easy to change it over time. However, because I recently purchased a solar panel, I decided to install a monitor for safety reasons. This 3-phase voltage relay can monitor the AC voltage before connecting to the grid, ensure voltage stability during the switching process, and prevent equipment damage or safety accidents due to voltage fluctuations. The high quality of the relay saved me a lot of trouble later.