Coriolis Mass Flow Meter for Air/Gas/Liquid, DN20-DN150

$6,684.56
High quality coriolis mass flowmeter good price for sale, this flowmeter is a new type of flow measurement instrument developed according to coriolis working principle, support DN20 to DN150 pass size optional, can real-time monitor the flow rate, density and temperature, especially suitable for the accurate measurement of air, gas and liquid.
SKU: ATO-FLOW-FCC
*
Free Shipping
Delivery date: 6-12 days

ATO coriolis mass flow meter can directly measure the mass flow of fluids, suitable for DN20-DN150 pass diameter, wide measuring range and high accuracy. Temperature range from -40°C~60°C, pressure range up to 4MPa, using 4-20mA output, support RS485 and MODBUS-RTU communication protocol to ensure stable and reliable data transmission. Coriolis flow meter has favorable price, now in hot sale, welcome to add the purchase.

Specification

ModelATO-FCC300
Nominal DiameterU type: DN20~DN150
Measuring VariableMass flow, density, temperature
Flow Measurement RangeReference Table Flow Meter Range
Density Measurement Range0.3~3000g/cm3
Temperature Range-200°C~300°C
Outputs4-20mA, output load 250~600Ω
Communication OutputsRS485 interface, MODBUS-RTU communication protocol, Hart
High Frequency (Pulse) OutputPulse width: 50%
Active: Output current 10mA, open circuit voltage 24V
Power Supply24VDC/220VAC
Power Consumption≤15W
Electrical InterfaceM20*1.5
Flow Rate0.2 grade, 0.5 grade
Density±0.002g/cm3
Temperature±1°C
Repeatability1/2 of measurement error
Process ConditionsStandard: -50°C~200°C, -20°C~200°C
Process Pressure0~4MPa
Pressure LossMaximum flow rate corresponds to pressure loss 100kPa (with water as medium)
Temperature-40°C~+60°C
Humidity35%RH~95%RH
Protection ClassIP67


Flow Meter Flow Range

Diameter (mm)Conventional Flow Meter Flow Range (kg/h)Zero Stability (kg/h)
DN200~6000~90000.6
DN250~9600~144000.96
DN320~18000~270001.8
DN400~30000~450003
DN500~48000~720004.8
DN800~120000~18000012
DN1000~192000~30000019.2
DN1500~360000036


Feature

  1. Coriolis flow meter principle is can directly measure the mass flow of fluid, wide measuring range, high accuracy.
  2. Coriolis flow meter installation requirements are low, no front and rear straight pipe section requirements.
  3. In addition to normal fluid measurement can also measure the general fluid measurement instrument is more difficult to measure the industrial media, such as high-viscosity fluids, slurries, suspensions and so on.
  4. On-line measurement of the measured medium density, temperature and other parameters, and thus derived from the measurement of the concentration of solutes in solution, reliable operation, low maintenance.

Dimension (unit: mm)

Coriolis mass flow meter size

Nominal DiameterA (mm)B (mm)C (mm)D (mm)E (mm)Weight (kg)
DN2054047846810824517
DN2554049246810824517.5
DN3254451746810824524
DN4060063550014026732
DN5060665350014026736
DN8086685777921931687.5
DN100950977833273340165
DN150130012231144324340252

Note: E represents the dimensions of the increase in center height with the integrated mounting of the converter.

Terminal Block Instructions

Coriolis mass flow meter terminal block instructions

SymbolDescription
RS485+, RS485-RS485 serial communication interface
mA1+, mA1-First 4~20mA output interface
mA2+, mA2-Second 4~20mA output interface
HartHart output interface (optional)
Freq+, Freq-Frequency (pulse) output interface
Power+, Power-Power supply interface
Ground SymbolConverter instrument protection interface


Drip Protection Schematic

Coriolis mass flow meter drip protection schematic

Attention

  • All housing screws, housing covers and cable entry glands must be tightened.
  • The mass flow meter housing gasket must be clean and intact when inserted into the sealing groove. The gasket may be dried, cleaned and replaced if necessary.
  • All wiring should be drip-protected, i.e. the cable inlet of the meter, the cable and the feed-through pipe should have a downward bend to avoid water ingress and short-circuiting.
  • All cable inlets must not face upwards without protection.
  • Unwanted cable inlets need to be sealed with plugs.

Application

Coriolis mass flow meter applications

Tips: What is a coriolis mass flow meter?

A coriolis mass flow meter is an instrument used to measure the flow of a fluid, based on the principle of the coriolis effect. Coriolis flow meter working principle that when a fluid flows through a pair of vibrating pipes, the flow of the fluid has an effect on the vibration of the pipes.

The mass flow rate of the fluid is directly proportional to the change in this vibration, so by detecting the change in vibration the mass flow rate of the fluid can be accurately calculated. Coriolis flow measurement is widely used for flow measurement of gases, liquids and steam.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

ATO coriolis mass flow meter can directly measure the mass flow of fluids, suitable for DN20-DN150 pass diameter, wide measuring range and high accuracy. Temperature range from -40°C~60°C, pressure range up to 4MPa, using 4-20mA output, support RS485 and MODBUS-RTU communication protocol to ensure stable and reliable data transmission. Coriolis flow meter has favorable price, now in hot sale, welcome to add the purchase.

Specification

ModelATO-FCC300
Nominal DiameterU type: DN20~DN150
Measuring VariableMass flow, density, temperature
Flow Measurement RangeReference Table Flow Meter Range
Density Measurement Range0.3~3000g/cm3
Temperature Range-200°C~300°C
Outputs4-20mA, output load 250~600Ω
Communication OutputsRS485 interface, MODBUS-RTU communication protocol, Hart
High Frequency (Pulse) OutputPulse width: 50%
Active: Output current 10mA, open circuit voltage 24V
Power Supply24VDC/220VAC
Power Consumption≤15W
Electrical InterfaceM20*1.5
Flow Rate0.2 grade, 0.5 grade
Density±0.002g/cm3
Temperature±1°C
Repeatability1/2 of measurement error
Process ConditionsStandard: -50°C~200°C, -20°C~200°C
Process Pressure0~4MPa
Pressure LossMaximum flow rate corresponds to pressure loss 100kPa (with water as medium)
Temperature-40°C~+60°C
Humidity35%RH~95%RH
Protection ClassIP67


Flow Meter Flow Range

Diameter (mm)Conventional Flow Meter Flow Range (kg/h)Zero Stability (kg/h)
DN200~6000~90000.6
DN250~9600~144000.96
DN320~18000~270001.8
DN400~30000~450003
DN500~48000~720004.8
DN800~120000~18000012
DN1000~192000~30000019.2
DN1500~360000036


Feature

  1. Coriolis flow meter principle is can directly measure the mass flow of fluid, wide measuring range, high accuracy.
  2. Coriolis flow meter installation requirements are low, no front and rear straight pipe section requirements.
  3. In addition to normal fluid measurement can also measure the general fluid measurement instrument is more difficult to measure the industrial media, such as high-viscosity fluids, slurries, suspensions and so on.
  4. On-line measurement of the measured medium density, temperature and other parameters, and thus derived from the measurement of the concentration of solutes in solution, reliable operation, low maintenance.

Dimension (unit: mm)

Coriolis mass flow meter size

Nominal DiameterA (mm)B (mm)C (mm)D (mm)E (mm)Weight (kg)
DN2054047846810824517
DN2554049246810824517.5
DN3254451746810824524
DN4060063550014026732
DN5060665350014026736
DN8086685777921931687.5
DN100950977833273340165
DN150130012231144324340252

Note: E represents the dimensions of the increase in center height with the integrated mounting of the converter.

Terminal Block Instructions

Coriolis mass flow meter terminal block instructions

SymbolDescription
RS485+, RS485-RS485 serial communication interface
mA1+, mA1-First 4~20mA output interface
mA2+, mA2-Second 4~20mA output interface
HartHart output interface (optional)
Freq+, Freq-Frequency (pulse) output interface
Power+, Power-Power supply interface
Ground SymbolConverter instrument protection interface


Drip Protection Schematic

Coriolis mass flow meter drip protection schematic

Attention

  • All housing screws, housing covers and cable entry glands must be tightened.
  • The mass flow meter housing gasket must be clean and intact when inserted into the sealing groove. The gasket may be dried, cleaned and replaced if necessary.
  • All wiring should be drip-protected, i.e. the cable inlet of the meter, the cable and the feed-through pipe should have a downward bend to avoid water ingress and short-circuiting.
  • All cable inlets must not face upwards without protection.
  • Unwanted cable inlets need to be sealed with plugs.

Application

Coriolis mass flow meter applications

Tips: What is a coriolis mass flow meter?

A coriolis mass flow meter is an instrument used to measure the flow of a fluid, based on the principle of the coriolis effect. Coriolis flow meter working principle that when a fluid flows through a pair of vibrating pipes, the flow of the fluid has an effect on the vibration of the pipes.

The mass flow rate of the fluid is directly proportional to the change in this vibration, so by detecting the change in vibration the mass flow rate of the fluid can be accurately calculated. Coriolis flow measurement is widely used for flow measurement of gases, liquids and steam.