Metal Tube Variable Area Flow Meter for Water/Gas/Liquid

$713.96
Metal tube variable area flow meter is used for the detection of water, gases and liquids, supports multiple output protocols with data backup, and power failure protection. Metal tube variable area flow meters offer excellent repeatability and help to accurately measure and precisely control complex industrial processes.
SKU: ATO-FLOW-MT
*
*
*
*
*
Free Shipping
Delivery date: 6-12 days

Metal tube variable area flow meter for sale, 4-20MA output, RS485, HART communication output optional. The flow meters can be used to detect the flow of liquids, gases and steam and are particularly suitable for flow measurement of low flow and small flow media.

Specification

ModelATO-LZ-20
Measuring RangeWater (20°C) (01-200000) L/h Air 20°C.0.1013MPa): (0.5~2000)m3/h
Range RatioStandard type 10:1 special type 20:1
Accuracy ClassStandard type 1.5 class, special type 1 class, gas type 1.5 class
Pressure LevelStandard type: DN15~DN50≤4.0MPa DN65~DN200≤ 1.6MPa
High Pressure TypeTemperature range: -80°C~200°C, DN15~DN100≤10MPa
Connection MethodFlange type,sanitary clamp type,common thread type,sanitary thread type
Medium TemperatureStandard type -20°C~120°C PTFE 0°C~80°C, high temperature type 120°C~450*C low temperature type -80°C-20°C
Ambient TemperatureRemote type: -40°C~+70°C (LCD will not be damaged) LCD normal operation at -20°C~+70°C, local pointer type, local alarm type: -40°C~+80°C
Power SupplyStandard type: 24VDC 2-wire (4 20) mA (12VDC ~32VDC)
Alarm Type24VDC multi-wire (4 20)mA (12VDC~32VDC)
AC Type(100~240) VAC 50Hz -60Hz
Battery Type3.6V@9AH lithium battery, can last for three years
Load CharacteristicsRLmax: 600 Intrinsically safe: 5000
Alarm OutputUpper and lower limit instantaneous flow alarm, optocoupler signal isolation Darlington tube output (internal 24VDC power supply maximum current 8mA. External power supply 250mA@36VDC)
Local alarm type: upper limit, lower limit or upper and lower limit instantaneous flow alarm Reed switch switch alarm (contact capacity 1A@30VDC) optional normally open and normally closed
The upper limit and lower limit alarm hold range is up to 60% of the range, and the minimum interval between the upper and lower limit alarms is 10% of the range
Pulse OutputThe cumulative pulse output is an optocoupler signal isolated Darlington tube output (internal 24VDC power supply, maximum current 8mA)
Protection ClassIP65
Intrinsically Safe ParametersUi≤28V li≤100mA Pi≤0.7W Ci≤0.021 μF Li≈0mH


Dimension (unit:mm)

Metal tube variable area flow meter sizes

Line SizeABWeight
DN151331393.6kg
DN251211395.5kg
DN321211396.1kg
DN401211396.6kg
DN501061589.6kg
DN809315813.35kg
DN10083.517916.9kg
DN15064.523423.4kg
DN2002923448.6kg


Details

Metal tube variable area flow meter details

Installation Method

  • Horizontal installation

Metal tube variable area flow meter horizontal installation

  • Parallel installation

Metal tube variable area flow meter parallel installation

Applications

Metal tube variable area flow meter application

Tips: What is the working principle of a metal tube variable area flow meter?

The metal tube variable area flow meter float is in the measuring tube. With the change of flow, the float moves upward, and the buoyancy of the float and the gravity of the float reach a balance at a certain position. At this time, the flow annulus area between the float and the orifice plate (or cone tube) remains constant. The area of the annular gap is proportional to the rising height of the float, that is, the rising position of the float in the measuring tube represents the flow rate, and the position of the changing float is transmitted by the internal magnet to the external indicator so that the indicator can correctly indicate the flow value at this time. . This makes the indicator housing, not in direct contact with the measuring tube, so even if limit switches or transmitters are installed, the instrument can be used under high temperature and high pressure working conditions.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Metal tube variable area flow meter for sale, 4-20MA output, RS485, HART communication output optional. The flow meters can be used to detect the flow of liquids, gases and steam and are particularly suitable for flow measurement of low flow and small flow media.

Specification

ModelATO-LZ-20
Measuring RangeWater (20°C) (01-200000) L/h Air 20°C.0.1013MPa): (0.5~2000)m3/h
Range RatioStandard type 10:1 special type 20:1
Accuracy ClassStandard type 1.5 class, special type 1 class, gas type 1.5 class
Pressure LevelStandard type: DN15~DN50≤4.0MPa DN65~DN200≤ 1.6MPa
High Pressure TypeTemperature range: -80°C~200°C, DN15~DN100≤10MPa
Connection MethodFlange type,sanitary clamp type,common thread type,sanitary thread type
Medium TemperatureStandard type -20°C~120°C PTFE 0°C~80°C, high temperature type 120°C~450*C low temperature type -80°C-20°C
Ambient TemperatureRemote type: -40°C~+70°C (LCD will not be damaged) LCD normal operation at -20°C~+70°C, local pointer type, local alarm type: -40°C~+80°C
Power SupplyStandard type: 24VDC 2-wire (4 20) mA (12VDC ~32VDC)
Alarm Type24VDC multi-wire (4 20)mA (12VDC~32VDC)
AC Type(100~240) VAC 50Hz -60Hz
Battery Type3.6V@9AH lithium battery, can last for three years
Load CharacteristicsRLmax: 600 Intrinsically safe: 5000
Alarm OutputUpper and lower limit instantaneous flow alarm, optocoupler signal isolation Darlington tube output (internal 24VDC power supply maximum current 8mA. External power supply 250mA@36VDC)
Local alarm type: upper limit, lower limit or upper and lower limit instantaneous flow alarm Reed switch switch alarm (contact capacity 1A@30VDC) optional normally open and normally closed
The upper limit and lower limit alarm hold range is up to 60% of the range, and the minimum interval between the upper and lower limit alarms is 10% of the range
Pulse OutputThe cumulative pulse output is an optocoupler signal isolated Darlington tube output (internal 24VDC power supply, maximum current 8mA)
Protection ClassIP65
Intrinsically Safe ParametersUi≤28V li≤100mA Pi≤0.7W Ci≤0.021 μF Li≈0mH


Dimension (unit:mm)

Metal tube variable area flow meter sizes

Line SizeABWeight
DN151331393.6kg
DN251211395.5kg
DN321211396.1kg
DN401211396.6kg
DN501061589.6kg
DN809315813.35kg
DN10083.517916.9kg
DN15064.523423.4kg
DN2002923448.6kg


Details

Metal tube variable area flow meter details

Installation Method

  • Horizontal installation

Metal tube variable area flow meter horizontal installation

  • Parallel installation

Metal tube variable area flow meter parallel installation

Applications

Metal tube variable area flow meter application

Tips: What is the working principle of a metal tube variable area flow meter?

The metal tube variable area flow meter float is in the measuring tube. With the change of flow, the float moves upward, and the buoyancy of the float and the gravity of the float reach a balance at a certain position. At this time, the flow annulus area between the float and the orifice plate (or cone tube) remains constant. The area of the annular gap is proportional to the rising height of the float, that is, the rising position of the float in the measuring tube represents the flow rate, and the position of the changing float is transmitted by the internal magnet to the external indicator so that the indicator can correctly indicate the flow value at this time. . This makes the indicator housing, not in direct contact with the measuring tube, so even if limit switches or transmitters are installed, the instrument can be used under high temperature and high pressure working conditions.