Control Transformers
The control transformer is a step up or step down isolation transformer, and also a multi-tap transformer that
has multiple taps on either the primary winding or the secondary winding. ATO offers single phase control transformer from 500VA to 10kVA power rating, AC primary supply from 110-480 volt, multiple secondary voltages applicable to AC 50Hz or 60Hz circuits, and can work continuously for a long time under rated load. Multi tap control transformers are usually used in machine tools and mechanical equipment as electrical control lighting and indicator lights power supply. Below is a list of all the single phase control transformer we provide. Find the right primary and secondary voltage you need, and other voltages that are not in the drop-down box can be customized.
3 Points for Buying a Control Power Transformers
When we purchase control transformers, we should pay attention to these safety requirements:
- Insulation resistance: The insulation resistance of the control transformer in the cold state shall not be lower than 10 MΩ; the insulation resistance of the control transformer in the hot and wet state shall not be lower than 2 MΩ.
- Dielectric strength: The electrical insulation strength of the control power transformer should be able to withstand the withstand voltage test of AC 50 Hz, 2 000 V sinusoidal AC voltage, and no breakdown or flashover occurs for 1 minute.
- Leakage current: The leakage current of the control transformer shall not exceed 3mA.
Step Up & Down Control Transformers Working Principle
The control transformer works according to the principle of electromagnetic induction. A transformer has two sets of coils: A primary coil and a secondary coil. The secondary coil is just outside the primary coil. When alternating current is applied to the primary coil, the iron core of the transformer generates an alternating magnetic field, and then the secondary coil generates an induced electromotive force. The primary winding and the secondary winding are commonly covered on the iron core so that they can be coupled with each other through magnetic circuits and circuit coupling, so that energy is transmitted from the primary winding to the secondary winding.
Relatively speaking, the main functions of more sophisticated equipment include: Preventing electric shock to workers, preventing interference, and obtaining appropriate voltage. Its working principle picture is as follows:
Functions of 500VA~10kVA Industrial Control transformers
A control transformer is a small dry-type transformer. It has the following three functions.
- Control transformers can facilitate access to the right voltage, but also change the voltage of AC power while changing the impedance.
- When the design power is not exceeded, the control transformer can also change the current.
- In different environments, the transformer is used for different purposes. The control transformer also has the function of anti-interference.
Control transformers are mainly used in AC 50Hz (or 60Hz), voltage 1000V and below in the circuit, under the rated load can work continuously for a long time. ATO control transformers are usually used in machine tools, machinery and equipment the control electrical appliances lighting, and indicator power.