Step down control transformer converts single phase 240V AC to 110/36/24V AC, input/ output voltage can be customized as your requirement. In general, for the 500VA control electric transformer, input rated voltage less than 500V, output rated voltage less than 240V, worked as control power supply for mechanical equipment and general electrical appliance and as power supply for work lighting and signal lamp.
Specifications
| Product Name | Single phase control transformer |
| Product Model | ATOBK-500VA |
| Winding Material* | Enameled copper wire or enameled aluminum wire (Optional) |
| Total Output Capacity | 500VA Note: (If your output includes multiple voltage levels, please email us with the capacity of each output. The total capacity should be the sum of all individual outputs. For example, if your outputs are aV and bV, then aV (capacity) + bV (capacity) = 500VA). |
| Primary Voltage* (VAC) | 110, 120, 208, 220, 230, 240, 380, 400, 480, 110/220, 120/240, 240/480...(Optional and Customized) |
| Secondary Voltage* (VAC) | 6, 12, 24, 36, 48, 110/48, 120/24, 208/36, 220/48, 230/36, 240/120, 120/24/12, 110/36/24, 127/36/6, 208/48/36/24...(Optional and Customized) |
| Frequency | 50 / 60Hz |
| Insulation Level | F / H |
| Withstand Voltage Test | Primary to secondary 2.5KV/min |
| Primary to safety ground 2.5KV/min | |
| Secondary to safety ground 1.5KV/min | |
| Insulation Resistance | Primary to secondary 2500V>100 megohm |
| Primary to safety ground 2500V>100 megohm | |
| Secondary to safety ground 1500V>100 megohm | |
| Induction Withstand Voltage Test | 125Hz/ 800V/min |
| Ground Resistance | 25A<80 milliohm |
| Cooling Method | Natural or air cooling |
| Transformation Ratio | <3% |
| Air Carrying Current | <6% |
| Impedance Voltage | about 6% |
| Total Losses | 0.1 |
| Efficiency | 80%~99% |
| Operating Temperature | -25℃~40℃ (40℃, 93% RH, 56 days) |
| Storage Temperature | -25℃~100℃ (40℃, 93% RH, 56 days) |
| Certificate | CE, ISO |
| Warranty | 12 months |
| Size | Overall size: 132*135*140mm, Hold distance for installation: 100*105mm, Installation hold: 12*7mm |
| Weight | 10kg |
Schematic diagram illustration

Control transformer dimension

| Overall size (mm) | Hole distance for installation (mm) | Installation hole (mm) | |||
| B | E | D | A | C | K x J |
| 132 | 135 | 140 | 100 | 105 | 12 x 7 |
Tips: ATO 500VA-10kVA control transformers working environment
- Ambient air temperature: -5℃~+40℃, the highest monthly mean temperature should not exceed +30℃.
- Altitude for installing place should not exceed 1000m.
- When the ambient air temperature is +40℃, the relative humidity should not exceed 50%, and it allows higher relative humidity under lower temperature. Max average humidity in the dampest month is 90%, meanwhile the lowest average temperature of this month is +25℃, and condensation on the product surface caused by temperature change should be taken into consideration.
Product reviews
Safe 500VA control transformer
Nathan
2/24/2021 1:10 AM
This 500VA control transformer can be used safely, its primary and secondary sides can be completely isolated, and the 240V input voltage can be reduced to 110/36/24V. High quality is trustworthy, and safety accidents such as leakage will not occur.
Was this review helpful? (0/0)
Control transformer has been used for a long time
Dillon
6/14/2022 3:14 AM
Control transformer quality workmanship as always, very satisfied with the ATO products, the use of very safe, voltage and power are very accurate, before buying 2 500VA control transformer, this time to buy back.
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
3000VA Control Transformer, 440/460/480V to 120/24V
ATO-T-BK3000VA
$897.69
This best industrial control transformer has 3000VA power rating, 1- phase, and step down the 440/460/480V three sets of primary voltages to 120/24V dual secondary voltage, it is usually used in machine tool working as local lighting, power of indicator light or the machine control electric appliance.