800VA Control Transformer, 220/380V to 120/48V

$425.69
Control and lighting purposed mini dry type air automatic mode transformer with 800VA capacity, single phase, 2 groups of 220/380V primary voltages and 2 groups of 120/48V sencondary voltage. Step down control transformer is suitable for circuit of AC 50/60Hz.
SKU: ATO-T-BK800VA
*
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 6-12 days

1-phase 800VA control transformer on sales, step down 220/380V AC input to 120/48V AC output in 50Hz or 60Hz system. Primary and secondary voltages are customizable and but should note that primary voltage not exceed 500V, secondary voltage not exceed 240V.

Specifications

Product NameSingle phase control transformer
Product ModelATOBK-800VA
Winding Material*Enameled copper wire or enameled aluminum wire (Optional)
Total Output Capacity800VA
Note: (If your output includes multiple voltage levels, please email us with the capacity of each output. The total capacity should be the sum of all individual outputs. For example, if your outputs are aV and bV, then aV (capacity) + bV (capacity) = 800VA).
Primary Voltage* (VAC)110, 120, 208, 220, 230, 240, 380, 400, 480, 110/220, 120/240, 240/480...(Optional and Customized)
Secondary Voltage* (VAC)6, 12, 24, 36, 48, 110/48, 120/24, 208/36, 220/48, 230/36, 240/120, 120/24/12, 110/36/24, 127/36/6, 208/48/36/24...(Optional and Customized)
Frequency50 / 60Hz
Insulation LevelF / H
Withstand Voltage TestPrimary to secondary 2.5KV/min
Primary to safety ground 2.5KV/min
Secondary to safety ground 1.5KV/min
Insulation ResistancePrimary to secondary 2500V>100 megohm
Primary to safety ground 2500V>100 megohm
Secondary to safety ground 1500V>100 megohm
Induction Withstand Voltage Test125Hz/ 800V/min
Ground Resistance25A<80 milliohm
Cooling MethodNatural or air cooling
Transformation Ratio<3%
Air Carrying Current<6%
Impedance Voltageabout 6%
Total Losses0.1
Efficiency80%~99%
Operating Temperature-25℃~40℃ (40℃, 93% RH, 56 days)
Storage Temperature-25℃~100℃ (40℃, 93% RH, 56 days)
CertificateCE, ISO
Warranty12 months
SizeOverall size: 150*135*155mm, Hold distance for installation: 120*115mm, Installation hold: 12*7mm
Weight13kg

Schematic diagram illustration

Control transformer schematic diagram illustration

 Control transformer dimension

Control transformer dimension

Overall size (mm)Hole distance for installation (mm)Installation hole (mm)
BEDACK x J
15013515512011512 x 7

Tips: 2 points should be noted when using 800VA control transformers

The control transformer is a kind of small dry-type transformer, which is often used as the power supply of local lighting, signal lamp or indicator lamp, and as the power supply of control circuit in electrical equipment. Two points should be paid attention to when using the control transformer: One is the power of the transformer, the other is the correct wiring.

  1. The total power of the load connected to the secondary side shall not be greater than the power of the control transformer, and short circuit is not allowed. Otherwise, the temperature will be too high, and transformer will be burned if it is serious.
  2. The primary and secondary wiring of the control transformer shall not be wrongly connected, especially the primary side wiring. The voltage value of the primary side shall be marked on its terminal. It is not allowed to connect the 380V power line to the 220V terminal, but the 220V power line can be connected to the 380V terminal. At this time, all the output voltage of the secondary side will be reduced by 1.73 times. The secondary side load shall be connected to the corresponding terminal according to its rated voltage, for example, the 6.3V indicator light shall be connected to the 6.3V terminal, the 36V lighting bulb of the machine tool shall be connected to the 36V terminal, and the 127V AC contactor coil of the machine tool shall be connected to the 127V terminal.
Product reviews
Excellent quality industrial control transformer
5
Bradlee
Avatar
3/16/2020 9:29 PM
Excellent quality industrial control transformer. It was a great price and was delivered quickly and saved me from resorting to more expensive options. I used this on my industrial saw machine. It fit perfect (I bought it to replace the old original) and works perfectly.
Was this review helpful? Yes No (0/0)
Received my specially customized control transformer
5
Gael
Avatar
6/14/2022 3:18 AM
Received my specially customized all-copper control transformer, the material is thick, the details of the treatment of good taste, even if a long time running will not appear heat phenomenon, stable voltage, reliable quality, the output voltage is also very accurate.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

1-phase 800VA control transformer on sales, step down 220/380V AC input to 120/48V AC output in 50Hz or 60Hz system. Primary and secondary voltages are customizable and but should note that primary voltage not exceed 500V, secondary voltage not exceed 240V.

Specifications

Product NameSingle phase control transformer
Product ModelATOBK-800VA
Winding Material*Enameled copper wire or enameled aluminum wire (Optional)
Total Output Capacity800VA
Note: (If your output includes multiple voltage levels, please email us with the capacity of each output. The total capacity should be the sum of all individual outputs. For example, if your outputs are aV and bV, then aV (capacity) + bV (capacity) = 800VA).
Primary Voltage* (VAC)110, 120, 208, 220, 230, 240, 380, 400, 480, 110/220, 120/240, 240/480...(Optional and Customized)
Secondary Voltage* (VAC)6, 12, 24, 36, 48, 110/48, 120/24, 208/36, 220/48, 230/36, 240/120, 120/24/12, 110/36/24, 127/36/6, 208/48/36/24...(Optional and Customized)
Frequency50 / 60Hz
Insulation LevelF / H
Withstand Voltage TestPrimary to secondary 2.5KV/min
Primary to safety ground 2.5KV/min
Secondary to safety ground 1.5KV/min
Insulation ResistancePrimary to secondary 2500V>100 megohm
Primary to safety ground 2500V>100 megohm
Secondary to safety ground 1500V>100 megohm
Induction Withstand Voltage Test125Hz/ 800V/min
Ground Resistance25A<80 milliohm
Cooling MethodNatural or air cooling
Transformation Ratio<3%
Air Carrying Current<6%
Impedance Voltageabout 6%
Total Losses0.1
Efficiency80%~99%
Operating Temperature-25℃~40℃ (40℃, 93% RH, 56 days)
Storage Temperature-25℃~100℃ (40℃, 93% RH, 56 days)
CertificateCE, ISO
Warranty12 months
SizeOverall size: 150*135*155mm, Hold distance for installation: 120*115mm, Installation hold: 12*7mm
Weight13kg

Schematic diagram illustration

Control transformer schematic diagram illustration

 Control transformer dimension

Control transformer dimension

Overall size (mm)Hole distance for installation (mm)Installation hole (mm)
BEDACK x J
15013515512011512 x 7

Tips: 2 points should be noted when using 800VA control transformers

The control transformer is a kind of small dry-type transformer, which is often used as the power supply of local lighting, signal lamp or indicator lamp, and as the power supply of control circuit in electrical equipment. Two points should be paid attention to when using the control transformer: One is the power of the transformer, the other is the correct wiring.

  1. The total power of the load connected to the secondary side shall not be greater than the power of the control transformer, and short circuit is not allowed. Otherwise, the temperature will be too high, and transformer will be burned if it is serious.
  2. The primary and secondary wiring of the control transformer shall not be wrongly connected, especially the primary side wiring. The voltage value of the primary side shall be marked on its terminal. It is not allowed to connect the 380V power line to the 220V terminal, but the 220V power line can be connected to the 380V terminal. At this time, all the output voltage of the secondary side will be reduced by 1.73 times. The secondary side load shall be connected to the corresponding terminal according to its rated voltage, for example, the 6.3V indicator light shall be connected to the 6.3V terminal, the 36V lighting bulb of the machine tool shall be connected to the 36V terminal, and the 127V AC contactor coil of the machine tool shall be connected to the 127V terminal.
Product reviews
Excellent quality industrial control transformer
5
Bradlee
Avatar
3/16/2020 9:29 PM
Excellent quality industrial control transformer. It was a great price and was delivered quickly and saved me from resorting to more expensive options. I used this on my industrial saw machine. It fit perfect (I bought it to replace the old original) and works perfectly.
Was this review helpful? Yes No (0/0)
Received my specially customized control transformer
5
Gael
Avatar
6/14/2022 3:18 AM
Received my specially customized all-copper control transformer, the material is thick, the details of the treatment of good taste, even if a long time running will not appear heat phenomenon, stable voltage, reliable quality, the output voltage is also very accurate.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews