3000VA Control Transformer, 440/460/480V to 120/24V

$897.69
This best industrial control transformer has 3000VA power rating, 1- phase, and step down the 440/460/480V three sets of primary voltages to 120/24V dual secondary voltage, it is usually used in machine tool working as local lighting, power of indicator light or the machine control electric appliance.
SKU: ATO-T-BK3000VA
*
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 6-12 days

3kVA single phase control transformer, converting 440/460/480V input to 120/24V output, fully electric isolation between the primary side and secondary sides, is suitable for circuit of AC 50/60Hz and rated voltage 500V and below.

Specifications

Product NameSingle phase control transformer
Product ModelATOBK-3000VA
Winding Material*Enameled copper wire or enameled aluminum wire (Optional)
Total Output Capacity3000VA
Note: (If your output includes multiple voltage levels, please email us with the capacity of each output. The total capacity should be the sum of all individual outputs. For example, if your outputs are aV and bV, then aV (capacity) + bV (capacity) = 3000VA).
Primary Voltage* (VAC)110, 120, 208, 220, 230, 240, 380, 400, 480, 110/220, 120/240, 240/480...(Optional and Customized)
Secondary Voltage* (VAC)6, 12, 24, 36, 48, 110/48, 120/24, 208/36, 220/48, 230/36, 240/120, 120/24/12, 110/36/24, 127/36/6, 208/48/36/24...(Optional and Customized)
Frequency50 / 60Hz
Insulation LevelF / H
Withstand Voltage TestPrimary to secondary 2.5KV/min
Primary to safety ground 2.5KV/min
Secondary to safety ground 1.5KV/min
Insulation ResistancePrimary to secondary 2500V>100 megohm
Primary to safety ground 2500V>100 megohm
Secondary to safety ground 1500V>100 megohm
Induction Withstand Voltage Test125Hz/ 800V/min
Ground Resistance25A<80 milliohm
Cooling MethodNatural or air cooling
Transformation Ratio<3%
Air Carrying Current<6%
Impedance Voltageabout 6%
Total Losses0.1
Efficiency80%~99%
Operating Temperature-25℃~40℃ (40℃, 93% RH, 56 days)
Storage Temperature-25℃~100℃ (40℃, 93% RH, 56 days)
CertificateCE, ISO
Warranty12 months
SizeOverall size: 192*175*190mm, Hold distance for installation: 140*160mm, Installation hold: 17*8mm
Weight30kg

Schematic diagram illustration

Control transformer schematic diagram illustration

 Control transformer dimension

Control transformer dimension

Overall size (mm)Hole distance for installation (mm)Installation hole (mm)
BEDACK x J
19217519014016012 x 8

Tips: Transformer No-load Operation vs. Load Operation

Transformer no-load operation

The no-load operation of the transformer refers to the working state that the primary winding of the transformer is connected to the power supply and the secondary winding is open circuited. At this time, the current in the primary winding is called the no-load current of the transformer. No load current produces no-load magnetic field. The electromotive force is induced in the primary and secondary windings under the action of the main magnetic field (i.e. the magnetic field of the primary and secondary windings are linked at the same time).

During no-load operation of the transformer, although there is no power output at the secondary side, the primary side still draws part of the active power from the grid to compensate for the hysteresis loss and eddy current loss caused in the core due to flux saturation, which is called iron loss for short. The magnitude of the hysteresis loss depends on the frequency of the power supply and the area of the hysteresis loop of the core material; the eddy current loss is proportional to the maximum flux density and the square of the frequency. In addition, there is copper consumption caused by no-load current. For different capacity transformers, the magnitude of no-load current and no-load loss is different. So when using a transformer, we must choose suitable capacity.

Transformer load operation

Load operation of the transformer refers to the working condition when the primary winding is connected to the power supply voltage and the secondary winding is connected to the load. At this time, the secondary side of the transformer also has current flow, the access circuit of the original transformer increases correspondingly compared with no-load, and the voltage of the secondary side will be affected by the load and change.

Product reviews
So far so good!
5
James
Avatar
4/28/2022 8:43 PM
Old control transformer died and I need a replacement. Good making and easy to install. Working good so far. I will buy it again if I need a new one. Highly recommend it, you will be glad.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

3kVA single phase control transformer, converting 440/460/480V input to 120/24V output, fully electric isolation between the primary side and secondary sides, is suitable for circuit of AC 50/60Hz and rated voltage 500V and below.

Specifications

Product NameSingle phase control transformer
Product ModelATOBK-3000VA
Winding Material*Enameled copper wire or enameled aluminum wire (Optional)
Total Output Capacity3000VA
Note: (If your output includes multiple voltage levels, please email us with the capacity of each output. The total capacity should be the sum of all individual outputs. For example, if your outputs are aV and bV, then aV (capacity) + bV (capacity) = 3000VA).
Primary Voltage* (VAC)110, 120, 208, 220, 230, 240, 380, 400, 480, 110/220, 120/240, 240/480...(Optional and Customized)
Secondary Voltage* (VAC)6, 12, 24, 36, 48, 110/48, 120/24, 208/36, 220/48, 230/36, 240/120, 120/24/12, 110/36/24, 127/36/6, 208/48/36/24...(Optional and Customized)
Frequency50 / 60Hz
Insulation LevelF / H
Withstand Voltage TestPrimary to secondary 2.5KV/min
Primary to safety ground 2.5KV/min
Secondary to safety ground 1.5KV/min
Insulation ResistancePrimary to secondary 2500V>100 megohm
Primary to safety ground 2500V>100 megohm
Secondary to safety ground 1500V>100 megohm
Induction Withstand Voltage Test125Hz/ 800V/min
Ground Resistance25A<80 milliohm
Cooling MethodNatural or air cooling
Transformation Ratio<3%
Air Carrying Current<6%
Impedance Voltageabout 6%
Total Losses0.1
Efficiency80%~99%
Operating Temperature-25℃~40℃ (40℃, 93% RH, 56 days)
Storage Temperature-25℃~100℃ (40℃, 93% RH, 56 days)
CertificateCE, ISO
Warranty12 months
SizeOverall size: 192*175*190mm, Hold distance for installation: 140*160mm, Installation hold: 17*8mm
Weight30kg

Schematic diagram illustration

Control transformer schematic diagram illustration

 Control transformer dimension

Control transformer dimension

Overall size (mm)Hole distance for installation (mm)Installation hole (mm)
BEDACK x J
19217519014016012 x 8

Tips: Transformer No-load Operation vs. Load Operation

Transformer no-load operation

The no-load operation of the transformer refers to the working state that the primary winding of the transformer is connected to the power supply and the secondary winding is open circuited. At this time, the current in the primary winding is called the no-load current of the transformer. No load current produces no-load magnetic field. The electromotive force is induced in the primary and secondary windings under the action of the main magnetic field (i.e. the magnetic field of the primary and secondary windings are linked at the same time).

During no-load operation of the transformer, although there is no power output at the secondary side, the primary side still draws part of the active power from the grid to compensate for the hysteresis loss and eddy current loss caused in the core due to flux saturation, which is called iron loss for short. The magnitude of the hysteresis loss depends on the frequency of the power supply and the area of the hysteresis loop of the core material; the eddy current loss is proportional to the maximum flux density and the square of the frequency. In addition, there is copper consumption caused by no-load current. For different capacity transformers, the magnitude of no-load current and no-load loss is different. So when using a transformer, we must choose suitable capacity.

Transformer load operation

Load operation of the transformer refers to the working condition when the primary winding is connected to the power supply voltage and the secondary winding is connected to the load. At this time, the secondary side of the transformer also has current flow, the access circuit of the original transformer increases correspondingly compared with no-load, and the voltage of the secondary side will be affected by the load and change.

Product reviews
So far so good!
5
James
Avatar
4/28/2022 8:43 PM
Old control transformer died and I need a replacement. Good making and easy to install. Working good so far. I will buy it again if I need a new one. Highly recommend it, you will be glad.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

500VA Control Transformer, 240V to 110/36/24V

ATO-T-BK500VA
$373.08
High efficiency single phase 500VA capacity control transformer is applicable for AC 50/60Hz, fully electric isolation between primary side and secondary sides, is designed to step down 240V input voltage to 110/36/24V three sets of output voltages.