75 kVA Isolation Transformer Features

  • 3-phase unit with 75 kVA power rating.
  • Primary voltage of 480V AC on the primary side and secondary voltage of 230V AC on the secondary side.
  • enclosure is IP 24 protection grade.
  • Better protection, high quality workmanship.

Specifications

BasicsModelATO-SG75KVA
Phase3 phase
Capacity75 kVA
Weight of Aluminium Wire TransformerOpen type: 312kg
Protected type: 367kg
Weight of Copper Wire TransformerOpen type: 310kg
Protected type: 358kg
Technical ParametersPrimary Voltage480V (Optional: 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Secondary Voltage220V (Optional: 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Voltage ConvertThree phase to three phase
Frequency50Hz / 60 Hz
Winding MaterialAluminium/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength3000V AC/1 min
Noise<35-65dB (1 meter)
Insulation GradeH level
Wiring ModeDyn11
Cooling ModeDry type air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 4 hours
Enclosure Protection GradeIP 24
CertificateCE, ISO
Warranty12 months
Working EnvironmentTemperature-15℃~+40℃
Humidity≤90%RH, without condensation
Altitude<1000m, non corrosive gas and conductive dust

Note:

Transformer can only convert voltage and CANNOT convert frequency.
Transformer CANNOT convert single phase voltage to 3 phase voltage.
Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients' requirements.

3 Phase Isolation Transformer Schematic Diagram

ATO isolation transformers schematic diagram

3 Phase Isolation Transformer Details

60-100 kVA 3 phase isolation transformer details

75 kVA Isolation Transformer Installation Dimension

60kVA 100kVA isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=620*350*600mmOpen type: a*b*c=560*360*530mm
Mouting size: d*e=420*200mmMouting size: d*e=380*210mm
Protected type: A*B*C=600*1050*980mmProtected type: A*B*C=550*950*930mm

Tips: Functions of ATO 3 phase isolation transformer

The main function of three phase isolation transformer on ATO.com is to fully insulate primary and secondary electricity and circuit. In addition, its iron core has great ability of high-frequency clutter rejection with the features of high-frequency and great loss. Isolation transformer commonly known as safety transformer is usually used to isolate high-frequency clutter from entering control loop.
Isolation transformer is designed for personal safety in the use, maintenance and commissioning of certain electrical appliance. Taken fixing a color TV as example, the power supply of the color TV is directly rectified into machine, so the chassis of machine could be charged. If a maintenance man cursorily touches this part circuit, he will get an electric shock that endangers his personal safety. In the process of inspection and testing, if the connection between instrument grounding and chassis may cause power supply short-circuited, resulting in the damage to transistors, integrated circuits and test equipment inside machine. Therefore, 3 phase isolation transformer should be used for the maintenance of certain household appliances.

How to Test Step Up & Step Down Isolation Transformer?

Need more detail of ATO isolation transformer? Here is a good explanation about it in this video. To test the accuracy of the transformer voltage, we take a 3000 VA single phase 220V iuput to 110V output isolation transformer as an example.

Product reviews
Shell rating of 75kVA isolation transformer
5
Tcosgrove
Avatar
7/15/2021 7:33 PM
Can you proivde isolation transformer with enclosure type: NEMA 4X FFT2?
Was this review helpful? Yes No (0/0)
ATO Responded
No, our transformer cannot reach enclosure type: NEMA 4X FFT2, and the outdoor rainproof enclosure can only reach IP24.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Step up or step down isolation transformer is manufactured direct sale and fully compliant with reduced low voltage regulations, is a is a non-ventilated transformer rated for hazardous locations as well as harsh industrial environments.

75 kVA Isolation Transformer Features

  • 3-phase unit with 75 kVA power rating.
  • Primary voltage of 480V AC on the primary side and secondary voltage of 230V AC on the secondary side.
  • enclosure is IP 24 protection grade.
  • Better protection, high quality workmanship.

Specifications

BasicsModelATO-SG75KVA
Phase3 phase
Capacity75 kVA
Weight of Aluminium Wire TransformerOpen type: 312kg
Protected type: 367kg
Weight of Copper Wire TransformerOpen type: 310kg
Protected type: 358kg
Technical ParametersPrimary Voltage480V (Optional: 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Secondary Voltage220V (Optional: 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Voltage ConvertThree phase to three phase
Frequency50Hz / 60 Hz
Winding MaterialAluminium/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength3000V AC/1 min
Noise<35-65dB (1 meter)
Insulation GradeH level
Wiring ModeDyn11
Cooling ModeDry type air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 4 hours
Enclosure Protection GradeIP 24
CertificateCE, ISO
Warranty12 months
Working EnvironmentTemperature-15℃~+40℃
Humidity≤90%RH, without condensation
Altitude<1000m, non corrosive gas and conductive dust

Note:

Transformer can only convert voltage and CANNOT convert frequency.
Transformer CANNOT convert single phase voltage to 3 phase voltage.
Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients' requirements.

3 Phase Isolation Transformer Schematic Diagram

ATO isolation transformers schematic diagram

3 Phase Isolation Transformer Details

60-100 kVA 3 phase isolation transformer details

75 kVA Isolation Transformer Installation Dimension

60kVA 100kVA isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=620*350*600mmOpen type: a*b*c=560*360*530mm
Mouting size: d*e=420*200mmMouting size: d*e=380*210mm
Protected type: A*B*C=600*1050*980mmProtected type: A*B*C=550*950*930mm

Tips: Functions of ATO 3 phase isolation transformer

The main function of three phase isolation transformer on ATO.com is to fully insulate primary and secondary electricity and circuit. In addition, its iron core has great ability of high-frequency clutter rejection with the features of high-frequency and great loss. Isolation transformer commonly known as safety transformer is usually used to isolate high-frequency clutter from entering control loop.
Isolation transformer is designed for personal safety in the use, maintenance and commissioning of certain electrical appliance. Taken fixing a color TV as example, the power supply of the color TV is directly rectified into machine, so the chassis of machine could be charged. If a maintenance man cursorily touches this part circuit, he will get an electric shock that endangers his personal safety. In the process of inspection and testing, if the connection between instrument grounding and chassis may cause power supply short-circuited, resulting in the damage to transistors, integrated circuits and test equipment inside machine. Therefore, 3 phase isolation transformer should be used for the maintenance of certain household appliances.

Product reviews
Shell rating of 75kVA isolation transformer
5
Tcosgrove
Avatar
7/15/2021 7:33 PM
Can you proivde isolation transformer with enclosure type: NEMA 4X FFT2?
Was this review helpful? Yes No (0/0)
ATO Responded
No, our transformer cannot reach enclosure type: NEMA 4X FFT2, and the outdoor rainproof enclosure can only reach IP24.