30 kVA Isolation Transformer, 3 phase, 480 Volt to 415 Volt

$5,129.37
High efficiency 30kVA solation transformer is dry type air self cooling one, which is available in the circuit of AC 50Hz/60Hz and convert 3 phase voltage 480V to 415V, step up 415V to 480V is optional, low cost and manufactured direct sale.
SKU: ATO-T-SG30KVA
*
*
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 10-16 days

30 kVA Isolation Transformer Features

  • 3-phase unit with 30 kVA power rating.
  • Primary voltage of 480V AC on the primary side and secondary voltage of 415V AC on the secondary side.
  • Have a minimum 1 year warranty.
  • Better protection, high quality workmanship.

Specifications

BasicsModelATO-SG30KVA
Phase3 phase
Capacity30 kVA
Weight of Aluminium Wire TransformerOpen type: 160kg
Protected type: 185kg
Weight of Copper Wire TransformerOpen type: 160kg
Protected type: 185kg
Technical ParametersPrimary Voltage480V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Secondary Voltage415V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Voltage ConvertThree phase to three phase
Frequency50Hz / 60 Hz
Winding MaterialAluminium/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength3000V AC/1 min
Noise<35-65dB (1 meter)
Insulation GradeH level
Wiring ModeDyn11
Cooling ModeDry type air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 4 hours
Enclosure Protection GradeIP 24
CertificateCE, ISO
Warranty12 months
Working EnvironmentTemperature-15℃~+40℃
Humidity≤90%RH, without condensation
Altitude<1000m, non corrosive gas and conductive dust

Note:

Transformer can only convert voltage and CANNOT convert frequency.
Transformer CANNOT convert single phase voltage to 3 phase voltage.
Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients' requirements.

3 Phase Isolation Transformer Schematic Diagram

ATO isolation transformers schematic diagram

3 Phase Isolation Transformer Details

3-phase isolation transformer details

30 kVA Isolation Transformer Installation Dimension

3 phase isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=440*350*430mmOpen type: a*b*c=440*340*420mm
Mouting size: d*e=300*205mmMouting size: d*e=300*195mm
Protected type: A*B*C=420*610*610mmProtected type: A*B*C=420*610*610mm

Tips: Characteristics of ATO isolation transformer at the AC power input

  1. If the third harmonic and interference signal of the Grid is severe, use isolation transformer to remove the third harmonic and reduce the interference signal.
  2. The use of isolation transformers can generate a new neutral line to avoid the abnormal operation of equipment caused by unfit neutral power line.
  3. The current waveform distortion(such as third harmonic) caused by nonlinear load can be isolated without affecting the Grid.

How to Test Step Up & Step Down Isolation Transformer?

Need more detail of ATO isolation transformer? Here is a good explanation about it in this video. To test the accuracy of the transformer voltage, we take a 3000 VA single phase 220V iuput to 110V output isolation transformer as an example.

Product reviews
Solid isolation transformer, good package
5
Naviathan
Avatar
1/8/2019 2:15 AM
I had to modify this transformer to use it for my purpose. I am using it as a safety device on my electronics service bench. It is a solid, well built unit.
Was this review helpful? Yes No (0/0)
Update invoice info
5
Andrey
Avatar
4/23/2019 1:50 AM
My order of 30kVA Isolation Transformer was shipped out and the invoice is in my name, is it possible to make an invoice in the company name?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we will modify and resend you.
Can ATO supply the isolation transformer we need?
5
Tpe
Avatar
1/26/2022 1:00 AM
Can you provide a 70kVA isolation transformer with 3 inputs (460V, 480V, 690V) and 1 output (440V)?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

30 kVA Isolation Transformer Features

  • 3-phase unit with 30 kVA power rating.
  • Primary voltage of 480V AC on the primary side and secondary voltage of 415V AC on the secondary side.
  • Have a minimum 1 year warranty.
  • Better protection, high quality workmanship.

Specifications

BasicsModelATO-SG30KVA
Phase3 phase
Capacity30 kVA
Weight of Aluminium Wire TransformerOpen type: 160kg
Protected type: 185kg
Weight of Copper Wire TransformerOpen type: 160kg
Protected type: 185kg
Technical ParametersPrimary Voltage480V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Secondary Voltage415V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Voltage ConvertThree phase to three phase
Frequency50Hz / 60 Hz
Winding MaterialAluminium/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength3000V AC/1 min
Noise<35-65dB (1 meter)
Insulation GradeH level
Wiring ModeDyn11
Cooling ModeDry type air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 4 hours
Enclosure Protection GradeIP 24
CertificateCE, ISO
Warranty12 months
Working EnvironmentTemperature-15℃~+40℃
Humidity≤90%RH, without condensation
Altitude<1000m, non corrosive gas and conductive dust

Note:

Transformer can only convert voltage and CANNOT convert frequency.
Transformer CANNOT convert single phase voltage to 3 phase voltage.
Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients' requirements.

3 Phase Isolation Transformer Schematic Diagram

ATO isolation transformers schematic diagram

3 Phase Isolation Transformer Details

3-phase isolation transformer details

30 kVA Isolation Transformer Installation Dimension

3 phase isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=440*350*430mmOpen type: a*b*c=440*340*420mm
Mouting size: d*e=300*205mmMouting size: d*e=300*195mm
Protected type: A*B*C=420*610*610mmProtected type: A*B*C=420*610*610mm

Tips: Characteristics of ATO isolation transformer at the AC power input

  1. If the third harmonic and interference signal of the Grid is severe, use isolation transformer to remove the third harmonic and reduce the interference signal.
  2. The use of isolation transformers can generate a new neutral line to avoid the abnormal operation of equipment caused by unfit neutral power line.
  3. The current waveform distortion(such as third harmonic) caused by nonlinear load can be isolated without affecting the Grid.
Product reviews
Solid isolation transformer, good package
5
Naviathan
Avatar
1/8/2019 2:15 AM
I had to modify this transformer to use it for my purpose. I am using it as a safety device on my electronics service bench. It is a solid, well built unit.
Was this review helpful? Yes No (0/0)
Update invoice info
5
Andrey
Avatar
4/23/2019 1:50 AM
My order of 30kVA Isolation Transformer was shipped out and the invoice is in my name, is it possible to make an invoice in the company name?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we will modify and resend you.
Can ATO supply the isolation transformer we need?
5
Tpe
Avatar
1/26/2022 1:00 AM
Can you provide a 70kVA isolation transformer with 3 inputs (460V, 480V, 690V) and 1 output (440V)?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can.
Only registered users can write reviews