60 kVA Isolation Transformer, 3 phase 190V to 3 phase 400V

$7,635.25
ATOSG-60KVA isolation transformers is 50/60 Hz rated, designed to step down 3 phase 400V AC to 3 phase 190V, step up 190V to 400V type is available, and come in a IP24 enclosure for indoor use.
SKU: ATO-T-SG60KVA
*
*
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 10-16 days

60 kVA, 3 phase 190V to 400V isolationt ransformers from ATO that is of superior quality. It is manufactured using high grade components and the latest technology to ensure high durable finish standards, maintenance free working, and high load capacity.

60 kVA Isolation Transformer Specifications

BasicsModelATO-SG60KVA
Phase3 phase
Capacity60 kVA
Weight of Aluminium Wire TransformerOpen type: 268kg
Protected type: 335kg
Weight of Copper Wire TransformerOpen type: 275kg
Protected type: 345kg
Technical ParametersPrimary Voltage190V (Optional: 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Secondary Voltage400V (Optional: 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Voltage ConvertThree phase to three phase
Frequency50Hz / 60 Hz
Winding MaterialAluminium/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength3000V AC/1 min
Noise<35-65dB (1 meter)
Insulation GradeH level
Wiring ModeDyn11
Cooling ModeDry type air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 4 hours
Enclosure Protection GradeIP 24
CertificateCE, ISO
Warranty12 months
Working EnvironmentTemperature-15℃~+40℃
Humidity≤90%RH, without condensation
Altitude<1000m, non corrosive gas and conductive dust

Note:

Transformer can only convert voltage and CANNOT convert frequency.
Transformer CANNOT convert single phase voltage to 3 phase voltage.
Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients' requirements.

3 Phase Isolation Transformer Schematic Diagram

ATO isolation transformers schematic diagram

3 Phase Isolation Transformer Details

60-100 kVA 3 phase isolation transformer details

60 kVA Isolation Transformer Installation Dimension

60kVA 100kVA isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=560*350*550mmOpen type: a*b*c=560*360*530mm
Mouting size: d*e=380*210mmMouting size: d*e=380*210mm
Protected type: A*B*C=550*950*930mmProtected type: A*B*C=550*950*930mm

Tips: Oil make-up of isolation transformer operation, what should be paid attention to?

60 kVA 3 phase isolation transformer oil make-up can be carried out without transformer electricity cut. Pay attention to the following matters during oil make-up:

  1. Pay attention to avoid mixing the oil, the new added oil should pass the test.
  2. Heavy gas protection should be changed to the signal position before oil make-up so as to prevent the gas protection from malfunctioning and tripping the 3 phase transformer.
  3. Pay attention to check the gas relay after oil make-up and release the gas in time. Only after the air of the transformer is exhausted can the heavy gas protection be re-put to the trip position.
  4. Make up the appropriate amount of oil, the oil level should fit the transformer oil temperature.
  5. It is forbidden to make up oil from the lower stop valve of the transformer to prevent the sediment at the bottom of the step up & step down transformer from being washed into the coil, which will affect the insulation and heat dissipation of the transformer.

How to Test Step Up & Step Down Isolation Transformer?

Need more detail of ATO isolation transformer? Here is a good explanation about it in this video. To test the accuracy of the transformer voltage, we take a 3000 VA single phase 220V iuput to 110V output isolation transformer as an example.

Product reviews
Looking for a right 3 phase isolation transformer
5
Roy Stevens
Avatar
9/16/2020 7:06 PM
Looking for a 3 phase isolation transformer 24kva minimum. We have a 240v 3ph service and need to test machinery at 380v (China) 415v (UK) and 480v (US).. Can you proivde?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, sure… you can use our 1-core primary and 3-core secondary transformer, but transformer capacity should be 100kVA, so you can get "100kVA/3" power capacity from each secondary core. Also, you can run the 3 cores in the same time.
100 kVA Isolation Transformer, Aluminium wire, with shell. (https://www.ato.com/100-kva-isolation-transformer)
Primary: 3-phase, 240V.
Secondary: 3 cores, 3-phase, 380V, 415V, 480V
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

60 kVA, 3 phase 190V to 400V isolationt ransformers from ATO that is of superior quality. It is manufactured using high grade components and the latest technology to ensure high durable finish standards, maintenance free working, and high load capacity.

60 kVA Isolation Transformer Specifications

BasicsModelATO-SG60KVA
Phase3 phase
Capacity60 kVA
Weight of Aluminium Wire TransformerOpen type: 268kg
Protected type: 335kg
Weight of Copper Wire TransformerOpen type: 275kg
Protected type: 345kg
Technical ParametersPrimary Voltage190V (Optional: 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Secondary Voltage400V (Optional: 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Voltage ConvertThree phase to three phase
Frequency50Hz / 60 Hz
Winding MaterialAluminium/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength3000V AC/1 min
Noise<35-65dB (1 meter)
Insulation GradeH level
Wiring ModeDyn11
Cooling ModeDry type air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 4 hours
Enclosure Protection GradeIP 24
CertificateCE, ISO
Warranty12 months
Working EnvironmentTemperature-15℃~+40℃
Humidity≤90%RH, without condensation
Altitude<1000m, non corrosive gas and conductive dust

Note:

Transformer can only convert voltage and CANNOT convert frequency.
Transformer CANNOT convert single phase voltage to 3 phase voltage.
Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients' requirements.

3 Phase Isolation Transformer Schematic Diagram

ATO isolation transformers schematic diagram

3 Phase Isolation Transformer Details

60-100 kVA 3 phase isolation transformer details

60 kVA Isolation Transformer Installation Dimension

60kVA 100kVA isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=560*350*550mmOpen type: a*b*c=560*360*530mm
Mouting size: d*e=380*210mmMouting size: d*e=380*210mm
Protected type: A*B*C=550*950*930mmProtected type: A*B*C=550*950*930mm

Tips: Oil make-up of isolation transformer operation, what should be paid attention to?

60 kVA 3 phase isolation transformer oil make-up can be carried out without transformer electricity cut. Pay attention to the following matters during oil make-up:

  1. Pay attention to avoid mixing the oil, the new added oil should pass the test.
  2. Heavy gas protection should be changed to the signal position before oil make-up so as to prevent the gas protection from malfunctioning and tripping the 3 phase transformer.
  3. Pay attention to check the gas relay after oil make-up and release the gas in time. Only after the air of the transformer is exhausted can the heavy gas protection be re-put to the trip position.
  4. Make up the appropriate amount of oil, the oil level should fit the transformer oil temperature.
  5. It is forbidden to make up oil from the lower stop valve of the transformer to prevent the sediment at the bottom of the step up & step down transformer from being washed into the coil, which will affect the insulation and heat dissipation of the transformer.
Product reviews
Looking for a right 3 phase isolation transformer
5
Roy Stevens
Avatar
9/16/2020 7:06 PM
Looking for a 3 phase isolation transformer 24kva minimum. We have a 240v 3ph service and need to test machinery at 380v (China) 415v (UK) and 480v (US).. Can you proivde?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, sure… you can use our 1-core primary and 3-core secondary transformer, but transformer capacity should be 100kVA, so you can get "100kVA/3" power capacity from each secondary core. Also, you can run the 3 cores in the same time.
100 kVA Isolation Transformer, Aluminium wire, with shell. (https://www.ato.com/100-kva-isolation-transformer)
Primary: 3-phase, 240V.
Secondary: 3 cores, 3-phase, 380V, 415V, 480V
Only registered users can write reviews
Customers who bought this item also bought

75 kVA Isolation Transformer, 3 phase, 480 Volt to 220 Volt

ATO-T-SG75KVA
$8,135.41
Safety 75kVA isolation transformer come in a NEMA 3R enclosure, which is available in the circuit of AC 50Hz/60Hz and convert 3 phase voltage 480V to 220V and 220V to 480V version is optional , low noise, lower temperature rise, higher efficiency.