5 hp NEMA AC Induction Motor, Three Phase 230/460V, ODP/TEFC

$1,072.22
3 phase 5 horsepower 2 pole general purpose NEMA AC induction motor running at 60 hertz 230/460 volt, providng max speed of 3450 rpm, ODP or TEFC enclosure types are available on ATO. High protection class and durability electric motor, low price and directly selling by manufacturer.
SKU: ATO-IM-RT52
*
This product has a minimum quantity of 10
Free Shipping
Delivery date: 6-12 days

NEMA design B electric induction motor or asynchronous motor is 5 hp, three phase, 3450rpm, 1.15SF, 182TC rolled steel frame with double shielded bearings, C face footed mounting. Each features a totally enclosed fan cooled motor enclosure design, which helps resist contamination by preventing air from moving freely between the inside and outside of the frame. You can also choose an open drip proof enclosure motor that runs cooler and does not overheat.

5 hp 3 phase AC Induction Motor Specification

BasicsModelATORT52D11ATORT52T11
EnclosureODPTEFC
TypeGeneral Purpose Asynchronous Motor
Item Weight98 Ibs
Motor Length16.5 inch18.5 inch
Frame182TC Frame184TC Frame
DesignNEMA Design B
CertificationCE, UL
Motor MaterialRoll Steel
Technical ParametersService Factor1.151.25
Horsepower5 hp
Rated Frequency60 Hz
PhaseThree Phase
Pole2 pole
Voltage230/460V AC
Full Load Amps11.8/5.9A11.5/5.77A
Speed3450 RPM
Efficiency88.5%
DutyContinuous
Isulation ClassClass F
Protection ClassIP54/ IP55
Mounting MethodC Face, Footed
EnvironmentAmbient temperature-15℃≤θ≤40℃
AltitudeAltitude should be lower than 1000 meters above sea level

5 hp 3 phase AC Induction Motor Dimension

3 phase nema ac induction motor dimension
Unit: inch

Frame
Size
ABBAMax
A
Max
B
Max
BB
Max
BD
CDE2FHN-WOPRSUMin
ES
Min
AA
AHBFBCAJAKMin
V
182TC7.23.58.56.50.25916.54.53.754.50.412.759.259.650.9860.251.1251.783/42.621/2-13+0.127.258.52.5
184TC7.23.58.56.50.25918.54.53.755.50.412.759.259.650.9860.251.1251.783/42.621/2-13+0.127.258.52.5

NEMA AC Induction Motor Connection Diagram

Nema induction motor connection diagram

Details

5 hp NEMA AC Induction Motor Details

Tips: Variable frequency speed control of AC Induction Motor
According to the speed formula of induction motor, it can be seen that when the slip s remains constant, the motor speed nis basically proportional to the power frequency f. Therefore, changing the frequency f can regulate the speed of induction motor smoothly. Changing the frequency of power supply is a economical speed regulation method, and it is also one of most popular ways of induction motor speed control.
Variable frequency speed control is a way to change the power frequency of motor stator and then change its synchronous speed. The main equipment of variable frequency speed control system is frequency converter or variable frequency drive (VFD) that provides frequency conversion for the power supply. The variable frequency drives can be divided into two categories: AC-DC-AC VFDs and AC-AC VFDs.

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

Product reviews
The 5hp AC induction motor satisfies my needs very well
5
Herner
Avatar
10/22/2021 2:58 AM
I bought this 5hp AC induction motor for general position control. After using it, I think it meets my requirements. I recommend you to buy it.
Was this review helpful? Yes No (0/0)
Installation and use problems of VFD
5
jorel
Avatar
2/5/2023 11:13 PM
I have a few other questions:
1. I am installing the VFD in an IP55 enclosure and I need to add 250V indicator lights on the enclosure door.
Is it ok to connect one leg of  the light to U terminal and the other to neutral to indicate the motor is running?
2. In my country we use PME, that means the neutral is bonded to earth.
Is it ok to connect the earth that has been bonded to neutral to the earth terminal of the VFD unit?
Was this review helpful? Yes No (0/0)
ATO Responded
1. If you want to install a running indicator light on the door panel when the VFD is running, you can use the VFD relay output signal to control it.
The terminal is TA/TB/TC (TA-TB: NO contact), the corresponding parameter is P4.12, set P4.12=0 (VFD running).
2. In this case, you can directly connect your local ground wire to the ground wire of the VFD (terminal marked E), or not ground.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

NEMA design B electric induction motor or asynchronous motor is 5 hp, three phase, 3450rpm, 1.15SF, 182TC rolled steel frame with double shielded bearings, C face footed mounting. Each features a totally enclosed fan cooled motor enclosure design, which helps resist contamination by preventing air from moving freely between the inside and outside of the frame. You can also choose an open drip proof enclosure motor that runs cooler and does not overheat.

5 hp 3 phase AC Induction Motor Specification

BasicsModelATORT52D11ATORT52T11
EnclosureODPTEFC
TypeGeneral Purpose Asynchronous Motor
Item Weight98 Ibs
Motor Length16.5 inch18.5 inch
Frame182TC Frame184TC Frame
DesignNEMA Design B
CertificationCE, UL
Motor MaterialRoll Steel
Technical ParametersService Factor1.151.25
Horsepower5 hp
Rated Frequency60 Hz
PhaseThree Phase
Pole2 pole
Voltage230/460V AC
Full Load Amps11.8/5.9A11.5/5.77A
Speed3450 RPM
Efficiency88.5%
DutyContinuous
Isulation ClassClass F
Protection ClassIP54/ IP55
Mounting MethodC Face, Footed
EnvironmentAmbient temperature-15℃≤θ≤40℃
AltitudeAltitude should be lower than 1000 meters above sea level

5 hp 3 phase AC Induction Motor Dimension

3 phase nema ac induction motor dimension
Unit: inch

Frame
Size
ABBAMax
A
Max
B
Max
BB
Max
BD
CDE2FHN-WOPRSUMin
ES
Min
AA
AHBFBCAJAKMin
V
182TC7.23.58.56.50.25916.54.53.754.50.412.759.259.650.9860.251.1251.783/42.621/2-13+0.127.258.52.5
184TC7.23.58.56.50.25918.54.53.755.50.412.759.259.650.9860.251.1251.783/42.621/2-13+0.127.258.52.5

NEMA AC Induction Motor Connection Diagram

Nema induction motor connection diagram

Details

5 hp NEMA AC Induction Motor Details

Tips: Variable frequency speed control of AC Induction Motor
According to the speed formula of induction motor, it can be seen that when the slip s remains constant, the motor speed nis basically proportional to the power frequency f. Therefore, changing the frequency f can regulate the speed of induction motor smoothly. Changing the frequency of power supply is a economical speed regulation method, and it is also one of most popular ways of induction motor speed control.
Variable frequency speed control is a way to change the power frequency of motor stator and then change its synchronous speed. The main equipment of variable frequency speed control system is frequency converter or variable frequency drive (VFD) that provides frequency conversion for the power supply. The variable frequency drives can be divided into two categories: AC-DC-AC VFDs and AC-AC VFDs.

Product reviews
The 5hp AC induction motor satisfies my needs very well
5
Herner
Avatar
10/22/2021 2:58 AM
I bought this 5hp AC induction motor for general position control. After using it, I think it meets my requirements. I recommend you to buy it.
Was this review helpful? Yes No (0/0)
Installation and use problems of VFD
5
jorel
Avatar
2/5/2023 11:13 PM
I have a few other questions:
1. I am installing the VFD in an IP55 enclosure and I need to add 250V indicator lights on the enclosure door.
Is it ok to connect one leg of  the light to U terminal and the other to neutral to indicate the motor is running?
2. In my country we use PME, that means the neutral is bonded to earth.
Is it ok to connect the earth that has been bonded to neutral to the earth terminal of the VFD unit?
Was this review helpful? Yes No (0/0)
ATO Responded
1. If you want to install a running indicator light on the door panel when the VFD is running, you can use the VFD relay output signal to control it.
The terminal is TA/TB/TC (TA-TB: NO contact), the corresponding parameter is P4.12, set P4.12=0 (VFD running).
2. In this case, you can directly connect your local ground wire to the ground wire of the VFD (terminal marked E), or not ground.
Only registered users can write reviews