1 hp NEMA AC Induction Motor, Three Phase 230/460V, ODP/TEFC

$676.43
Three phase 230/460V AC induction with 1hp, 2 pole, 1.25 SF, C face footed mounting, 3450 rpm, 143TC frame with open drip proof (ODP) enclosure, you may choose totally enclosed fan cooled (TEFC) enclosure as well. It features NEMA B design which providing low starting current and high locked rotor torque, suited for a broad variety of applications.
SKU: ATO-IM-RT12
*
Free Shipping
Delivery date: 6-12 days

1 hp 3 phase AC Induction Motor Features

  • 1 horsepower 2 pole 1.25 service factor 143TC frame size AC electric motor
  • 3 phase small AC general purpose asynchronous motor running at 60Hz 230/460V AC
  • Has aluminum windings for conductivity and energy efficiency and has a operating speed of 3450 rpm
  • Available with open drip proof (ODP) enclosure motor and totally enclosed fan cooled (TEFC) enclosure motor
  • Double shielded bearings and Class F insulation

1 hp 3 phase AC Induction Motor Specification

BasicsModelATORT12D11ATORT12T11
EnclosureODPTEFC
TypeGeneral Purpose Asynchronous Motor
Item Weight39 Ibs
Motor Length14.6 inch
Frame143TC Frame
DesignNEMA Design B
CertificationCE, UL
Motor MaterialRoll Steel
Technical ParametersService Factor1.151.25
Horsepower1 hp
Rated Frequency60 Hz
PhaseThree Phase
Pole2 pole
Voltage230/460V AC
Full Load Amps3.13/1.57A
Speed3450 RPM
Efficiency77%
DutyContinuous
Isulation ClassClass F
Protection ClassIP54/ IP55
Mounting MethodC Face, Footed
EnvironmentAmbient temperature-15℃≤θ≤40℃
AltitudeAltitude should be lower than 1000 meters above sea level

1 hp 3 phase AC Induction Motor Dimension

3 phase nema ac induction motor dimension
Unit: inch

Frame
Size
ABBAMax
A
Max
B
Max
BB
Max
BD
CDE2FHN-WOPRSUMin
ES
Min
AA
AHBFBCAJAKMin
V
143TC5.62.7576.180.166.514.63.52.7540.342.256.77.080.7710.1880.8751.413/42.121/2-13+0.125.8754.52

NEMA AC Induction Motor Connection Diagram

Nema induction motor connection diagram

Details

1 hp NEMA AC Induction Motor Details

Tips: Induction motor doesn’t revolve, why and how to do?

  1. The power source is not connected.
    If the power source is not connected or bad contact, the motor will not revolve. At this moment, the electrician must inspect the switch, fuse, various contacts and connection wires. Thus, the fault will be gradually troubleshooting for maintenance.
  2. The fuse is blown out when starting.
    Find the reason for the fuse blown, troubleshoot the fault and then fit the proper fuse for the motor.
  3. The setting current of the over-current relay is too low.
    For this problem, just regulate higher properly.
  4. The load is too large or the transmission mechanism blocks.
    In this case, choose an induction motor with bigger capacity or relieve the load, and also check the condition of the transmission mechanism.
  5. The stator or rotor winding is in open circuit.
    Open the terminal box and check if the motor winding is broken (leads breakage) with the Ohm gear of the multi-meter. If any open circuit occurs, the resistance value might be abnormal. It is required to open the motor to make further inspection and connect the breakage point.

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

1 hp 3 phase AC Induction Motor Features

  • 1 horsepower 2 pole 1.25 service factor 143TC frame size AC electric motor
  • 3 phase small AC general purpose asynchronous motor running at 60Hz 230/460V AC
  • Has aluminum windings for conductivity and energy efficiency and has a operating speed of 3450 rpm
  • Available with open drip proof (ODP) enclosure motor and totally enclosed fan cooled (TEFC) enclosure motor
  • Double shielded bearings and Class F insulation

1 hp 3 phase AC Induction Motor Specification

BasicsModelATORT12D11ATORT12T11
EnclosureODPTEFC
TypeGeneral Purpose Asynchronous Motor
Item Weight39 Ibs
Motor Length14.6 inch
Frame143TC Frame
DesignNEMA Design B
CertificationCE, UL
Motor MaterialRoll Steel
Technical ParametersService Factor1.151.25
Horsepower1 hp
Rated Frequency60 Hz
PhaseThree Phase
Pole2 pole
Voltage230/460V AC
Full Load Amps3.13/1.57A
Speed3450 RPM
Efficiency77%
DutyContinuous
Isulation ClassClass F
Protection ClassIP54/ IP55
Mounting MethodC Face, Footed
EnvironmentAmbient temperature-15℃≤θ≤40℃
AltitudeAltitude should be lower than 1000 meters above sea level

1 hp 3 phase AC Induction Motor Dimension

3 phase nema ac induction motor dimension
Unit: inch

Frame
Size
ABBAMax
A
Max
B
Max
BB
Max
BD
CDE2FHN-WOPRSUMin
ES
Min
AA
AHBFBCAJAKMin
V
143TC5.62.7576.180.166.514.63.52.7540.342.256.77.080.7710.1880.8751.413/42.121/2-13+0.125.8754.52

NEMA AC Induction Motor Connection Diagram

Nema induction motor connection diagram

Details

1 hp NEMA AC Induction Motor Details

Tips: Induction motor doesn’t revolve, why and how to do?

  1. The power source is not connected.
    If the power source is not connected or bad contact, the motor will not revolve. At this moment, the electrician must inspect the switch, fuse, various contacts and connection wires. Thus, the fault will be gradually troubleshooting for maintenance.
  2. The fuse is blown out when starting.
    Find the reason for the fuse blown, troubleshoot the fault and then fit the proper fuse for the motor.
  3. The setting current of the over-current relay is too low.
    For this problem, just regulate higher properly.
  4. The load is too large or the transmission mechanism blocks.
    In this case, choose an induction motor with bigger capacity or relieve the load, and also check the condition of the transmission mechanism.
  5. The stator or rotor winding is in open circuit.
    Open the terminal box and check if the motor winding is broken (leads breakage) with the Ohm gear of the multi-meter. If any open circuit occurs, the resistance value might be abnormal. It is required to open the motor to make further inspection and connect the breakage point.