This offered 3hp AC induction motor comes with 182T roll steel frame, NEMA B design which providing low starting current and high locked rotor torque. Single phase, 2 pole, 3450 RPM, 230V AC electric motor, is suitable for compressors, pumps, fans, machine tools, and air conditioning units applications.
SKU: ATO-IM-RS32
*
Free Shipping
Delivery date: 6-12 days

3 hp AC Induction Motor Features

  • 3 hp 2 pole 1SF 182T frame NEMA design B AC induction motor or asynchronous motor
  • Small single phase electric motor running @ 60Hz 230V AC, full load amps is 13.1A
  • Available with open drip proof (ODP) enclosure motor and totally enclosed fan cooled (TEFC) enclosure motor
  • Has aluminum windings for conductivity and energy efficiency and has a operating speed of 3450 rpm
  • Double shielded bearings and Class F insulation
  • Provides for fully automatic operations and excellent functionality

3 hp AC Induction Motor Specification

BasicsModelATORS32D01ATORS32T01
EnclosureODPTEFC
TypeGeneral Purpose Asynchronous Motor
Item Weight81 Ibs
Motor Length18.8 inch
Frame182T Frame
DesignNEMA Design B
CertificationCE, UL
Motor MaterialRoll Steel
Technical ParametersService Factor1.151
Horsepower3 hp
Rated Frequency60 Hz
PhaseSingle Phase
Pole2 pole
Voltage230V AC
Full Load Amps13.1A
Speed3450 RPM
Efficiency78%
DutyContinuous
Isulation ClassClass F
Protection ClassIP54/ IP55
Mounting MethodFoot Mounted
EnvironmentAmbient temperature-15℃≤θ≤40℃
AltitudeAltitude should be lower than 1000 meters above sea level

3 hp AC Induction Motor Dimension
182T Single Phase AC Induction Motor Dimension
Unit: inch

Frame SizeABBAMax AMax BCDE2FHNN-WOPRSUMin VMin ESMin AA
182T7.22.758.56.516.54.53.754.50.412.982.759.259.250.9860.251.1252.51.783/4

NEMA AC Induction Motor Connection Diagram

Nema induction motor connection diagram

Details

3hp NEMA AC Induction Motor Details

Tips: The Application Difference between Synchronous Motor and Asynchronous Motor
Synchronous motor can adjust the power factors flexibly through excitation while the power factors of asynchronous motor are not adjustable. Therefore, in some big factories with high asynchronous motor application, one synchronous motor can be equipped for phase adjustment, so as to adjust the power factors between the factory and network interface. However, since synchronous motor has manufacturing cost and large maintenance work amount, capacitance compensation power factor is generally used now.
Because synchronous motor has field winding and slip ring, the operation workers are required to have a high level to control excitation. In addition, compared with the free-maintenance performance of asynchronous motor, the maintenance work amount is great. Therefore, when used as the motor, asynchronous motor is mostly used.

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

3 hp AC Induction Motor Features

  • 3 hp 2 pole 1SF 182T frame NEMA design B AC induction motor or asynchronous motor
  • Small single phase electric motor running @ 60Hz 230V AC, full load amps is 13.1A
  • Available with open drip proof (ODP) enclosure motor and totally enclosed fan cooled (TEFC) enclosure motor
  • Has aluminum windings for conductivity and energy efficiency and has a operating speed of 3450 rpm
  • Double shielded bearings and Class F insulation
  • Provides for fully automatic operations and excellent functionality

3 hp AC Induction Motor Specification

BasicsModelATORS32D01ATORS32T01
EnclosureODPTEFC
TypeGeneral Purpose Asynchronous Motor
Item Weight81 Ibs
Motor Length18.8 inch
Frame182T Frame
DesignNEMA Design B
CertificationCE, UL
Motor MaterialRoll Steel
Technical ParametersService Factor1.151
Horsepower3 hp
Rated Frequency60 Hz
PhaseSingle Phase
Pole2 pole
Voltage230V AC
Full Load Amps13.1A
Speed3450 RPM
Efficiency78%
DutyContinuous
Isulation ClassClass F
Protection ClassIP54/ IP55
Mounting MethodFoot Mounted
EnvironmentAmbient temperature-15℃≤θ≤40℃
AltitudeAltitude should be lower than 1000 meters above sea level

3 hp AC Induction Motor Dimension
182T Single Phase AC Induction Motor Dimension
Unit: inch

Frame SizeABBAMax AMax BCDE2FHNN-WOPRSUMin VMin ESMin AA
182T7.22.758.56.516.54.53.754.50.412.982.759.259.250.9860.251.1252.51.783/4

NEMA AC Induction Motor Connection Diagram

Nema induction motor connection diagram

Details

3hp NEMA AC Induction Motor Details

Tips: The Application Difference between Synchronous Motor and Asynchronous Motor
Synchronous motor can adjust the power factors flexibly through excitation while the power factors of asynchronous motor are not adjustable. Therefore, in some big factories with high asynchronous motor application, one synchronous motor can be equipped for phase adjustment, so as to adjust the power factors between the factory and network interface. However, since synchronous motor has manufacturing cost and large maintenance work amount, capacitance compensation power factor is generally used now.
Because synchronous motor has field winding and slip ring, the operation workers are required to have a high level to control excitation. In addition, compared with the free-maintenance performance of asynchronous motor, the maintenance work amount is great. Therefore, when used as the motor, asynchronous motor is mostly used.

Only registered users can write reviews