400A High Voltage DC Contactor, 12V/24V coil

$220.49
Favorable price high voltage DC contactor for sale, with 400 amps rated load current of contact circuit, 1NO or 1NC contact form, available with 6V/12V/24V/36V/48V/60V/72V/84V/120V/150V/220V DC, 220V AC coils. This magnetic HVDC contactor is an electrical device designed to control and switch high voltage direct current circuits.
SKU: ATO-DCCON-HV400
*
*
Free Shipping
Delivery date: 6-12 days

400A high voltage DC contactor operates as a switch, allowing or interrupting the flow of DC electricity in high voltage applications, typically ranging from a few hundred volts to several kilovolts. These HVDC contactors are crucial in various industrial and commercial applications, such as electric vehicles (EVs), renewable energy systems (like solar and wind), railways, and power distribution networks.

Specification

ModelATO-SEV400AH
Contact Form (Optional)1NO or 1NC
Coil Rated Voltage (Optional)6V/12V/24V/36V/48V/60V/72V/84V/120V/150V/220V DC, 220V AC
Contact Rated Voltage5-1000V DC
Contact Circuit Rated Load Current400A(DC-1)
Main Contact Voltage Drop>80mV (Under 100A Load)
Cooling Pull-in Voltage>70% (20±5℃)
Cooling Release Operating Voltage>35%,<5% (20±5℃)
Coil Operating Voltage Range0.8-1.2Us (40℃)
Power-on Action Time80ms
Power-off Release Time20ms
Max. Bounce Time of Contact Connection10ms
Max. Bounce Time of Contact Disconnection7ms
Insulation Resistance100mΩ
Dielectric Strength50Hz/60Hz 2200VAC 1 Minute
Max. Switching Capacity of Main Contact1500A/5ms at 48V DC (Power on for 5ms)
Coil Power ConsumptionH: Start 30-60W, Maintain 4-10W
Coil Temperature Rise≤45K
Terminal Temperature Rise≤65K
Electrical Life20000 Times
Mechanical Life300000 Times
Work SpecificationsContinuous
Contact MaterialAlloy
Maximum Influx Time130ms
Maximum Switching Current2500A 320VDC (More Than 1 Time)
Maximum Switching Power800kW
Load Terminal TypeM10 Screw
Coil Terminal Type0.3 Square Silicone Wire, 390mm Long
Auxiliary Contact Rated Load3A/30VDC
Contact Terminal M10 Tightening Torque>20.5N.m
Coil Lead MethodWire Ends Dipped in tin (red+, black-)
Ambient Temperature-40~+85℃
Relative Humidity+20℃ 98%
Vibration Frequency of Fixed Place3G, 1~50Hz, Amplitude 0.5mm
Impact(60~100) Times/min, Acceleration ≤4g
Altitude2000 Meters
Installation DirectionAny
Protection LevelIP68
CertificationCE, FCC, RoHS


Load Characteristic Curve

400A high voltage DC contactor load characteristic curve

Coil Temperature Rise Curve

400A high voltage DC contactor coil temperature rise curve

Installation Dimension

400A high voltage DC contactor installation dimension

Wiring Diagram

400A high voltage DC contactor wiring diagram

Tips: How does a high voltage DC contactor work?

A high voltage DC contactor is an electrical switching device used to control and switch high-voltage DC circuits. Here's how it works:

  • Electromagnet drive: When the contactor coil is energized, the electromagnet generates a magnetic field that attracts the movable contacts and makes them come into contact with the stationary contacts, thus closing the circuit.
  • Arc extinguishing device: In a high-voltage DC circuit, an arc is generated when the circuit is opened. The contactor is equipped with a special arc extinguishing device, such as a magnetic blowing device or an air blowing device. The arc is elongated, cooled and finally extinguished by arc blowing to ensure safe breaking.
  • Auxiliary contacts: Contactors are also equipped with auxiliary contacts for controlling signal circuits or providing status feedback.
  • Mechanical structure: The mechanical interlocking mechanism inside the contactor ensures that the contacts move quickly and reliably during the opening and closing processes, reducing arc generation time and loss.

High voltage DC contactors are widely used in power systems, rail transit, energy storage systems and other fields to provide efficient and safe current control and protection.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

400A high voltage DC contactor operates as a switch, allowing or interrupting the flow of DC electricity in high voltage applications, typically ranging from a few hundred volts to several kilovolts. These HVDC contactors are crucial in various industrial and commercial applications, such as electric vehicles (EVs), renewable energy systems (like solar and wind), railways, and power distribution networks.

Specification

ModelATO-SEV400AH
Contact Form (Optional)1NO or 1NC
Coil Rated Voltage (Optional)6V/12V/24V/36V/48V/60V/72V/84V/120V/150V/220V DC, 220V AC
Contact Rated Voltage5-1000V DC
Contact Circuit Rated Load Current400A(DC-1)
Main Contact Voltage Drop>80mV (Under 100A Load)
Cooling Pull-in Voltage>70% (20±5℃)
Cooling Release Operating Voltage>35%,<5% (20±5℃)
Coil Operating Voltage Range0.8-1.2Us (40℃)
Power-on Action Time80ms
Power-off Release Time20ms
Max. Bounce Time of Contact Connection10ms
Max. Bounce Time of Contact Disconnection7ms
Insulation Resistance100mΩ
Dielectric Strength50Hz/60Hz 2200VAC 1 Minute
Max. Switching Capacity of Main Contact1500A/5ms at 48V DC (Power on for 5ms)
Coil Power ConsumptionH: Start 30-60W, Maintain 4-10W
Coil Temperature Rise≤45K
Terminal Temperature Rise≤65K
Electrical Life20000 Times
Mechanical Life300000 Times
Work SpecificationsContinuous
Contact MaterialAlloy
Maximum Influx Time130ms
Maximum Switching Current2500A 320VDC (More Than 1 Time)
Maximum Switching Power800kW
Load Terminal TypeM10 Screw
Coil Terminal Type0.3 Square Silicone Wire, 390mm Long
Auxiliary Contact Rated Load3A/30VDC
Contact Terminal M10 Tightening Torque>20.5N.m
Coil Lead MethodWire Ends Dipped in tin (red+, black-)
Ambient Temperature-40~+85℃
Relative Humidity+20℃ 98%
Vibration Frequency of Fixed Place3G, 1~50Hz, Amplitude 0.5mm
Impact(60~100) Times/min, Acceleration ≤4g
Altitude2000 Meters
Installation DirectionAny
Protection LevelIP68
CertificationCE, FCC, RoHS


Load Characteristic Curve

400A high voltage DC contactor load characteristic curve

Coil Temperature Rise Curve

400A high voltage DC contactor coil temperature rise curve

Installation Dimension

400A high voltage DC contactor installation dimension

Wiring Diagram

400A high voltage DC contactor wiring diagram

Tips: How does a high voltage DC contactor work?

A high voltage DC contactor is an electrical switching device used to control and switch high-voltage DC circuits. Here's how it works:

  • Electromagnet drive: When the contactor coil is energized, the electromagnet generates a magnetic field that attracts the movable contacts and makes them come into contact with the stationary contacts, thus closing the circuit.
  • Arc extinguishing device: In a high-voltage DC circuit, an arc is generated when the circuit is opened. The contactor is equipped with a special arc extinguishing device, such as a magnetic blowing device or an air blowing device. The arc is elongated, cooled and finally extinguished by arc blowing to ensure safe breaking.
  • Auxiliary contacts: Contactors are also equipped with auxiliary contacts for controlling signal circuits or providing status feedback.
  • Mechanical structure: The mechanical interlocking mechanism inside the contactor ensures that the contacts move quickly and reliably during the opening and closing processes, reducing arc generation time and loss.

High voltage DC contactors are widely used in power systems, rail transit, energy storage systems and other fields to provide efficient and safe current control and protection.

Only registered users can write reviews
Customers who bought this item also bought

150A High Voltage DC Contactor, 12V/24V coil

ATO-DCCON-HV150
$154.92
High voltage contactor, 150A rated load current of contact circuit, operating voltage up to 900V, normally open type (SPST-NO), is specially design to meet the requirements of high voltage DC switching applications.