3 Phase 4 Wires SCR Power Controller, 6/9/12/24kW

$142.38
SCR power controller is a simple power regulator, can regulate voltage & power and control temperature. Rated power can select 6kW/9kW/12kW/24kW. Control signals are optional in 4-20mA, 0-5VDC, 0-10VDC. Rated voltage is 380VAC and input is 3-phase 4-wire. The SCR controller is small in size, convenient for installation and wiring, and affordable.
SKU: ATO-PRG-KW
*
*
Free Shipping
Delivery date: 6-12 days

Application

  • Electric furnace industry: oven, drying, vacuum, trolley electric furnace, aging treatment, heat treatment, etc.
  • Machinery: packaging, extrusion, injection molding, infrared heating, etc.
  • Chemistry industry: pipeline heating, temperature compensation, petrochemical, etc.
  • Automotive industry: spray drying, thermoforming, etc.

Specification

ModelATO-SCR3-KW-3/4
Rated Voltage3 Phase 380VAC, Fan 220VAC
Wires3 Phase 4-Wire
Rated Power6kW, 9kW, 12kW, 24kW
Control Signal4-20mA, 0-5VDC, 0-10VDC
Product TypeSimple Type
Operation Frequency50Hz/60Hz
CertificationCE
Outline Dimension (L*W*H)140mm*100mm*145mm
Installation Dimension (L*W)80mm*90mm
Output Modephase output
Use Environmenttemperature<45℃, humidity<90%RH

Wiring Diagram of 3 Phase 4-Wire SCR Power Controller

Wiring Diagram of 3 Phase 4-Wire SCR Power Controller

Phase Output of 3 Phase 4-Wire SCR Power Controller

Dimension Drawing of 3 Phase 4-Wire SCR Power Controller (mm)

Dimension Drawing of 3 Phase 4-Wire SCR Power Controller

Details

3 Phase 4 Wires SCR Power Controller Details

Precautions

  1. Main circuit adopts 3-phase 4-wire input, no phase sequence is required.
  2. SCR is high current product, please be sure to lock the (R.S.T) and (U.V.W) terminals, otherwise the terminals will heat up and the SCR will burn out.
  3. When using 3-phase load Y type connection, the center point of Y must be connected to zero line. If the center line of Y is not connected to zero line, the 3-phase load needs to be relatively balanced.
  4. When using the module, if load power is greater than 15kW, it is recommended to use a suitable heat sink, and apply thermal silicone grease between the heat sink and the SCR base plate, and use air cooling. When power is greater than 15kW, be sure to strengthen the use of heat sink.
  5. Module protection: Please use semiconductor fast fuse for load overcurrent protection.
Product reviews
I will buy an SCR power controller again
5
Deanar
Avatar
9/23/2021 12:47 AM
I want to buy a 3 phase 4 wires SCR power controller that is simple to operate and durable. This SCR power controller meets all my needs. I am very happy to buy this SCR power controller.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Application

  • Electric furnace industry: oven, drying, vacuum, trolley electric furnace, aging treatment, heat treatment, etc.
  • Machinery: packaging, extrusion, injection molding, infrared heating, etc.
  • Chemistry industry: pipeline heating, temperature compensation, petrochemical, etc.
  • Automotive industry: spray drying, thermoforming, etc.

Specification

ModelATO-SCR3-KW-3/4
Rated Voltage3 Phase 380VAC, Fan 220VAC
Wires3 Phase 4-Wire
Rated Power6kW, 9kW, 12kW, 24kW
Control Signal4-20mA, 0-5VDC, 0-10VDC
Product TypeSimple Type
Operation Frequency50Hz/60Hz
CertificationCE
Outline Dimension (L*W*H)140mm*100mm*145mm
Installation Dimension (L*W)80mm*90mm
Output Modephase output
Use Environmenttemperature<45℃, humidity<90%RH

Wiring Diagram of 3 Phase 4-Wire SCR Power Controller

Wiring Diagram of 3 Phase 4-Wire SCR Power Controller

Phase Output of 3 Phase 4-Wire SCR Power Controller

Dimension Drawing of 3 Phase 4-Wire SCR Power Controller (mm)

Dimension Drawing of 3 Phase 4-Wire SCR Power Controller

Details

3 Phase 4 Wires SCR Power Controller Details

Precautions

  1. Main circuit adopts 3-phase 4-wire input, no phase sequence is required.
  2. SCR is high current product, please be sure to lock the (R.S.T) and (U.V.W) terminals, otherwise the terminals will heat up and the SCR will burn out.
  3. When using 3-phase load Y type connection, the center point of Y must be connected to zero line. If the center line of Y is not connected to zero line, the 3-phase load needs to be relatively balanced.
  4. When using the module, if load power is greater than 15kW, it is recommended to use a suitable heat sink, and apply thermal silicone grease between the heat sink and the SCR base plate, and use air cooling. When power is greater than 15kW, be sure to strengthen the use of heat sink.
  5. Module protection: Please use semiconductor fast fuse for load overcurrent protection.
Product reviews
I will buy an SCR power controller again
5
Deanar
Avatar
9/23/2021 12:47 AM
I want to buy a 3 phase 4 wires SCR power controller that is simple to operate and durable. This SCR power controller meets all my needs. I am very happy to buy this SCR power controller.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews