Features
- Linear phase shift control circuit control circuit, good stability and high accuracy. Modular, high pressure resistant, anti-interference.
- Protection method is built-in fast fuse.
- Adopts vacuum welding technology, optimized heat dissipation, good quality, long service life, safety and reliability.
- With multi-function LED to indicate working status.
Specification
| Model | ATO-AYSCR-LA | ATO-J3SCR-LA | |||
| Rated Voltage | 3 Phase 380VAC | 3 Phase 380VAC | |||
| Wires | 3 Phase 3-Wire | 3 Phase 3-Wire | |||
| Rated Current (Should be at least twice the actual current) | 25A | 40A | 75A | 90A | |
| Load | Y connection method (220V AC) | 8kW | 13kW | 23kW | 30kW |
| ▲ connection method (380V AC) | 14kW | 22kW | 40kW | 50kW | |
| Auxiliary Power | - | 220VAC | |||
| Control Signal | 4-20mA, 0-5VDC, 0-10VDC | 4-20mA, 0-5VDC, 0-10VDC (3 ways can switch) | |||
| Protection Function | fast fuse | ||||
| Certification | CE | ||||
| Operation Frequency | 50Hz/60Hz | ||||
| Output Mode | phase output | ||||
| Use Environment | temperature<45℃ humidity<90%RH | ||||
Star (Y) Type Wiring Diagram of 3 Phase 3-Wire SCR Power Regulator

Triangle Wiring Diagram of 3 Phase 3-Wire SCR Power Regulator


Details

Precautions
- Main circuit uses 3-phase 3-wire input, no phase sequence is required.
- SCR is high current product, please be sure to lock the (R.S.T) and (U.V.W) terminals, otherwise the terminals will heat up and the SCR will burn out.
- SCR has a built-in fast fuse for over current and short circuit protection. If the fuse is blown due to overcurrent, first check the load for faults such as short circuit and partial discharge. After troubleshooting, open the panel and replace it. Be sure to replace it with fuse of the same specification. Be careful not to increase amperage of the fuse at will.
- When using the load Y type wiring method, center point cannot be connected to zero line, otherwise the SCR will lose control. If 3-phase load is unbalanced, center point must be connected to zero line.
Product reviews
Whether the 3-phase 3-wire power regulator can keep the amperage stable
Bjorn
7/5/2021 11:43 PM
Wondering about the 3 phase 3 wire scr power regulator. It says for power and voltage regulation. Does that mean it's good for holding amperage steady?
Was this review helpful? (0/0)
Information about the 3 phase 3 wire power regulator
Rick
7/23/2021 12:57 AM
Wondering about the 3 phase 3 wire scr power regulator. It says for power and voltage regulation.
Was this review helpful? (0/0)
The role of 3 phase 3 wire power regulator
Melon
8/25/2021 3:19 AM
Wondering about the 3 phase 3 wire scr power regulator. It says for power and voltage regulation. Does that mean it's good for holding amperage steady?
Was this review helpful? (0/0)
Pleased with this SCR power regulator
Shaun
6/24/2022 3:43 AM
I'm very pleased with this 3 phase 3-wire SCR power regulator. It has four voltages to choose from. Power controller comes with protection function and good quality. I will order more.
Was this review helpful? (1/0)
Control of the voltage
Karl
5/29/2024 3:42 PM
Hi what does it mean E2 and E3 must be shorted when external VR is not used?
Is there a wiring diagram for the internal VR?
Thanks
Karl
Is there a wiring diagram for the internal VR?
Thanks
Karl
Was this review helpful? (0/0)
Reliable and precise
William
9/29/2025 12:47 AM
This regulator delivers stable power control for our heating system. Easy to install and the multi-signal input is helpful. The thermal management works well under continuous operation.
Was this review helpful? (0/0)
Only registered users can write reviews